Background: The objective of this in vitro study was to evaluate the vertical marginal fit of crowns fabricated with ZrO2 CAD/CAM, before and after porcelain firing cycles and after glaze cycles. Materials and Methods: An acrylic resin model of a left maxillary first molar was prepared and duplicated to have Nickel-Chromium master die. Ten die stone dies were sent to the CAD/CAM (Amann Girrbach) for crowns fabrication. Marginal gaps along vertical planes were measured at four indentations at the (mid mesial, mid distal, mid buccal, mid palatal) before (Time 0) and after porcelain firing cycles (Time 1) and after glaze cycles (Time 2) using a light microscope at a magnification of ×100. One way ANOVA LSD tests were performed to determine whether the mean and standard deviation of sub group Time 2. Results: The mean values of the ZrO2 CAD/CAM Time 0 were (6.77?m), Time 1(8.75?m) and Time 2(10.62 ?m). One way ANOVA test revealed highly statistical significance(P<0.01). LSD test results showed that there is highly significant difference between time (0) and time (2), while there is no any significant difference between time (0) and time (1), and between time (1) and time (2). Conclusions: Within the limitations of this study, it was concluded that the ZrO2 CAD/CAM demonstrated acceptable marginal fit; The porcelain firing and the glaze firing cycles affected the marginal gap
A variety of new phenolic Schiff bases derivatives have been synthesized starting from Terephthaladehyde compound, all proposed structures were supported by FTIR, 1H-NMR, 13C-NMR, Elemental analysis, some derivatives evaluated by Thermal analysis (TGA).
واحدة من أكثر مواد السيراميك الهيكلية الواعدة هي كربيد السيليكون(SiC) ، حيث له خصائص حرارية وكهروميكانيكية ممتازة. هذه الخصائص مفيدة ل CMC لتعزيز أداء المركب خاصة عند إضافات النانو المتكاملة. في هذا البحث, تم تصنيع مركب SiC من SiC بثلاثة تركيزات مع ZnO و Si. تم اختبار الخواص المغناطيسية لجميع المخاليط باستخدام مراقبة العينة الاهتزازية (VSM). تم تلبيد العينات الخضراء في فرن التلبيد عند 1600 درجة مئوية في بيئة النيتروجي
... Show MoreTo damp the low-frequency oscillations which occurred due to the disturbances in the electrical power system, the generators are equipped with Power System Stabilizer (PSS) that provide supplementary feedback stabilizing signals. The low-frequency oscillations in power system are classified as local mode oscillations, intra-area mode oscillation, and interarea mode oscillations. A suitable PSS model was selected considering the low frequencies oscillation in the inter-area mode based on conventional PSS and Fuzzy Logic Controller. Two types of (FIS) Mamdani and suggeno were considered in this paper. The software of the methods was executed using MATLAB R2015a package.
Background: Acute appendicitis is the most common surgical abdominal emergency with a life time prevalence of 1 to 7 individuals. Because the clinical diagnosis of acute appendicitis remains a challenge to surgeons, so different aids were introduced like different scoring systems, computer aided programs, ultrasonography, computerized tomography, Magnetic resonance imaging, Gastrointestinal tract contrast studies and laparoscopy to improve the diagnostic accuracy.
Objective: To evaluate ultrasound in the diagnosis of acute appendicitis in those patients clinically diagnosed with histopathology as gold standard.
Methods: A cross sectional study carried in Al-kindy Teaching
... Show MoreBackground: Acute appendicitis is a common surgical
problem that is associated with an acute-phase reaction.
Previous studies have shown that cytokines and acutephase proteins are activated and may serve as indicators for
appendicitis.
Objective: The aim of this study was to evaluate of serum
levels of interleukin-6 (IL-6) in correlation to the severity
to acute appendicitis.
Methods: This is a prospective study from December 2008
to March 2009 of patients who had appendectomy in
Department of Surgery, Al-Kindy Teaching Hospital -
Baghdad/Iraq. Serum for estimating levels of interleukin-6
(IL-6) was taken pre-operatively. Depending on the
macroscopic evidence during the operation and the
histopathol
The aim of this study is to investigate the role of prodigiosin on P. aeruginosa' s biofilm genes involved in the pathogenicity and persistency of the bacteria; Materials and methods: Gram negative bacterial isolates were taken from burn and wounds specimen obtained from some of Baghdad hospitals. Forty six isolates were identified as Pseudomonas aeruginosa and four isolates as Serratia marcescens by using biochemical tests and VITEK 2 compact system. Susceptibility test was performed for all P. aeruginosa isolates, the results showed that 100% were resistant to Amikacin and 98% were sensitive to Meropenem. Resistant isolates were tested for biofilm formation; the strong and moderate isolates (17) were detected by PCR for AlgD gene
... Show MoreThe aim: In this study, we present and evaluate the vest-over-pants technique as a simple way to correct urethrocutaneous fistulas after hypospadias. Materials and methods: Between October 2018 and June 2020, twenty male patients aged 5 to 20 years came to us with post hypospadias repair fistula, these patients underwent vest-over-pant repair of their fistula. The size of fistula was ranging between 2.5-5 mm. The distribution of fistula was coronal (3 patients), distal penile (9 patients), midshaft (2 patients) and proximal penile (6 patients). In 14 patients there were single fistula and 6 patients had more than one fistula. Eleven of patients were exposed to a previous failed fistula repair procedure. Results: Six months after the operati
... Show MoreXXXX
This work was conducted to study the treatment of industrial waste water, and more particularly those in the General Company of Electrical Industries.This waste water, has zinc ion with maximum concentration in solution of 90 ppm.
The reuse of such effluent can be made possible via appropriate treatments, such as chemical coagulation, Na2S is used as coagulant.
The parameters that influenced the waste water treatment are: temperature, pH, dose of coagulant and settling time.
It was found that the best condition for zinc removal, within the range of operation used ,were a temperature of 20C a pH value of 13 , a coagulant dose of 15 g Na2S /400ml solution and a settling time of 7 days. Under these conditions the zinc concentrat