Background: Prophylaxis methods are used to mechanically remove plaque and stain from tooth surfaces; such methods give rise to loss of superficial structure and roughen the surface of composites as a result of their abrasive action. This study was done to assess the effect of three polishing systems on surface texture of new anterior composites after storage in artificial saliva. Materials and methods: A total of 40 Giomer and Tetric®N-Ceram composite discs of 12 mm internal diameter and 3mm height were prepared using a specially designed cylindrical mold and were stored in artificial saliva for one month and then samples were divided into four groups according to surface treatment: Group A (control group):10 specimens received no surface polish and were subdivided into A1 (Giomer) and A2 (Tetric®N-Ceram). Group B: 10 specimens received polishing with Air polishing devise (APD) and were subdivided into B1 (Giomer) and B2 (Tetric®N-Ceram). Group C: 10 specimens received polishing with pumice and brush and were subdivided into C1 (Giomer) and C2 (Tetric®N-Ceram). Group D: 10 specimens were polished with pumice and rubber cup and were subdivided into D1 (Giomer) and D2 (Tetric®N-Ceram). Testing was done by means of profilometer and statistically analyzed using analysis of variance test (ANOVA), LSD and student t-test. Also samples were photographed by special orthoplane camera using light polarizing microscope. Results: The results showed a highly statistical significant difference in surface roughness among Giomer subgroups P<0.05. Also there was a highly significant difference P<0.05 when comparing Tetric subgroups according to type of surface treatment. Furthermore there was non-significant difference P>0.05 between groups according to the type of restorative material used. Conclusion: The use of prophylactic surface treatment significantly increased Giomer and Tetric ceram surface roughness and the use of rotating brush has shown the roughest surface among all other types of prophylactic protocols also Giomer had shown more surface roughness than Tetric ceram although the difference was not significant.
This work comprises the synthesis of new thioxanthone derivatives containing C-substituted thioxanthone. To obtain these derivatives, the o-mercapto benzoic acid was chosen as the starting material, which was reacted with dry benzene in sulfuric acid (98 %) to produce the thioxanthone (1). The 2,7-(disulfonyl phosphine imine) thioxanthone (4-8) were prepared from reaction of compound (1) with chlorosulfonic acid gave 2,7-(disulfonyl chloride) thioxanthone (2). Treatment of (2) with sodium azide to produce 2,7-(disulfonyl azide) thioxanthone (3). Condensation of (3) with phosphorus compounds afforded compounds (4-8). The 2,7-(disulfonamide) thioxanthone (9-21) was obtained when co
... Show MoreIn contrast to the classical antibacterial sulfa drugs that are unsubstituted or monosubstituted, our newly synthesized analogs were designed to obtain sulfonamide moiety containing disubstituted hetero nitrogen atom. These compounds were formed successfully by chlorosulfonation of acetanilide and the product was treated with different cyclic amines and finally amide hydrolysis was necessary to get agents that were analyzed for IR, UV, CHN, melting points and solubility. At last, we studied their antibacterial activity on certain types of bacteria and we noticed the inactivity due to possible steric factor. Principly, this means these products have no inhibiting action against the used microbes.
The reaction of some new Schiff bases ( 2-[(2-Amino – ethylimino)-methyl]-R , 2-({2-[(R-benzylidene)-amino]-ethylimino}-methyl)-R with Benzoyl chloride or Acetyl chloride were carried out. Subsequent reactions of these products N-(2-Amino-ethyl)-N-[Chloro-(R) –methyl]-benzamide or N-(2-{?-[chloro-(R) –methyl]-amino}-ethyl)-N-[chloro-(R) –methyl]- benzamide with thiourea afforded thioureas compounds. The synthesized compounds were confirmed by their IR,UV,spectra and C.H.N. analysis.
There is a variety of artificial foot designs variable for use with prosthetic legs . Most of the design can be divided into two classes, articulated and non-articulated feet. one common non-articulated foot is the SACH . The solid ankle cushion heel foot referred to as the SACH foot has a rigid keel .
One key or the key factor in designing a new prosthesis is in the analysis of a patients response .
This view is the most important because if the foot does not provide functional , practical or cosmetically acceptable characteristics the patient will not feel comfortable with the prosthesis , therefore design and manufacturing a new foot is essential, this foot made from polyethylene, its different shape and characte
... Show MoreEstablishing the systemic character of vocabulary, its relationship with other language systems, their interdependence creates the possibility of a comprehensive scientific study and description of the lexical system of each language, as well as contrastive comparative studies of several languages, including their phraseological composition.
It is known that not all words-components of phraseological units are equivalent in their role in the formation of the semantic content of phraseological units. In this regard, it is necessary to introduce the concept of a lexical dominant. To this we include words, which are kind of centers around which the entire semantic complex of phraseological units, the entire set of its words-componen
... Show MoreThis study aimed to manufacture an innovative device that enables the player to walk after the operation and improves the functional efficiency through the improvement in the range of motion as well as the improvement in the size of the muscles working on the knee joint. The research, the study population consisted of players with severing the anterior cruciate ligament of the advanced soccer players, and the number of the research sample was (5) injured for the control sample and (5) for the experimental sample in Abu Ghraib Hospital and some rehabilitation centers for a period of six months, and the pre-tests were conducted after two weeks of The cruciate ligament surgery was performed, and the innovative device was used for the e
... Show MoreThis paper is submitted as anew approach to simulate manufacturing control & planning system to define the problem of designing control system on the needs for materials.
Production planning & control is a total and complex operation, resides in the essence of manufacturing companies operations. The successful process of production planning and control systems is critical for the staying of manufacturing organizations in markets leading to the increasing consumer competition and which dominate most of manufacturing sectors because of the market oriented economy , thus , what has happened previously , that the companies possessed a great inventory of crude material, components, and groupings and they use in flexible techni
... Show MoreLasers, with their unique characteristics in terms of excellent beam quality, especially directionality and coherency, make them the solution that is key for many processes that require high precision. Lasers have good susceptibility to integrate with automated systems, which provides high flexibility to reach difficult zones. In addition, as a processing tool, a laser can be considered as a contact-free tool of precise tip that became attractive for high precision machining at the micro and nanoscales for different materials. All of the above advantages may be not enough unless the laser technician/engineer has enough knowledge about the mechanism of interaction between the laser light with the processed material. Several sequential phenom
... Show MorePolyetheretherketone (PEEK) has favorable biomechanical properties to be used as an implant material. Unfortunately, it is hydrophobic and does not promote cellular adhesion, which could result in poor integration with bone tissue. Bio-functionalization of PEEK surface with osteogenic peptides derived from bone extracellular matrix proteins is an exciting approach to encourage bone formation around the implant. In the current study, bone-forming peptide-2 was immobilized on PEEK surface using two different methods, using dopamine and a diglycidyl ether as conjugate compounds, respectively. Peptide quantification test revealed that the two strategies resulted in the most amount of peptides were attached with 0.5 mM concentration and no furth
... Show More