Preferred Language
Articles
/
jbcd-130
Effect of post-pressing times on adaptation of maxillary heat cured acrylic denture base at posterior palatal seal area
...Show More Authors

Background: The purpose of this study was to verify the influence of post- pressing time of acrylic resin (immediate, 6, 12 and 24 hour) on the dimensional accuracy of denture base whish is a critical factor in the retention and stability of the complete denture that may occur during polymerization shrinkage. Materials and Methods: Forty maxillary stone casts were poured in plastic mold (Columbia Dentoform corp. NEW YORK, type III dental stone (Geastone, Zeus Sri Loc.Tamburine Roccastrada, GR, Italy). The stone casts were randomly assigned into 4 groups of 10 specimens each according to the post-pressing times into (immediate, 6, 12 and 24 h.). Heat cure acrylic resin denture base was constructed according to the previously mentioned pressing time, the resin base-stone cast sets were transversally sectioned with a manual saw device at the distal aspect of the molar area, anterior to the posterior palatal seal area. The gap between the resin base and stone cast was measured at five points in the right (point B) and left (point D) ridge crests, at the midline (point C), and at the right (point A) and left (point E) marginal limits (A), using a Leitz linear optical comparator microscope with a travelling stage capable of measuring 0.001 mm. Each measurement was repeated three times and the average was used as the linear gap distance for that point. The data were submitted to ANOVA. Result: there was statistically significant difference between the pressing time in which the mean values of gap space in point E for 24h shows lowest value then point A, point B, and point D than the other post pressing time. The mean value in point C shows highest values which mean the greater gap space in palatal area.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Oct 12 2020
Journal Name
Molecules
Phase Change Process in a Zigzag Plate Latent Heat Storage System during Melting and Solidification
...Show More Authors

Applying a well-performing heat exchanger is an efficient way to fortify the relatively low thermal response of phase-change materials (PCMs), which have broad application prospects in the fields of thermal management and energy storage. In this study, an improved PCM melting and solidification in corrugated (zigzag) plate heat exchanger are numerically examined compared with smooth (flat) plate heat exchanger in both horizontal and vertical positions. The effects of the channel width (0.5 W, W, and 2 W) and the airflow temperature (318 K, 323 K, and 328 K) are exclusively studied and reported. The results reveal the much better performance of the horizontal corrugated configuration compared with the smooth channel during both melti

... Show More
View Publication
Scopus (40)
Crossref (37)
Scopus Clarivate Crossref
Publication Date
Wed Dec 30 2009
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Mass Transfer Correlations for a Rotating Cylinder Electrode under lsothermal and Controlled Heat Transfer Condition
...Show More Authors

Mass transfer correlations for iron rotating cylinder electrode in chloride/sulphate solution, under isothermal and
controlled heat transfer conditions, were derived. Limiting current density values for the oxygen reduction reaction from
potentiostatic experiments at different bulk temperatures and various turbulent flow rates, under isothermal and heat
transfer conditions, were used for such derivation. The corelations were analogous to that obtained by Eisenberg et all
and other workers.

View Publication Preview PDF
Publication Date
Sat Oct 01 2011
Journal Name
Journal Of Engineering
SOLAR WATER HEATER WITH SHELL AND HELICAL COILED TUBE HEAT EXCHANGER AS A STORAGE TANK
...Show More Authors

In this work an experimental study is performed to evaluate the thermal performance
of locally made closed loop solar hot water system using a shell and helical coiled tube
heat exchanger as a storage tank. Several measurements are taken include inlet and outlet
temperatures of both collectors and supply water and temperature distribution within the
storage tank. This is beside the water flow rate in both collectors and load cycle. The
main parameters of the system are obtained.

View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Tue Jan 15 2019
Journal Name
Association Of Arab Universities Journal Of Engineering Sciences
Natural Convective Heat Transfer in an Inclined Open Porous Cavity with Non-Uniformly Heated Wall
...Show More Authors

Theoretical and experimental investigations of free convection through a cubic cavity with sinusoidal heat flux at bottom wall, the top wall is exposed to an outside ambient while the other walls are adiabatic saturated in porous medium had been approved in the present work. The range of Rayleigh number was and Darcy number values were . The theoretical part involved a numerical solution while the experimental part included a set of tests carried out to study the free convection heat transfer in a porous media (glass beads) for sinusoidal heat flux boundary condition. The investigation enclosed values of Rayleigh number (5845.6, 8801, 9456, 15034, 19188 and 22148) and angles of inclinations (0, 15, 30, 45 and 60 degree). The numerical an

... Show More
Publication Date
Sun Aug 07 2022
Journal Name
Nanomaterials
Efficient Heat Transfer Augmentation in Channels with Semicircle Ribs and Hybrid Al2O3-Cu/Water Nanofluids
...Show More Authors

Global technological advancements drive daily energy consumption, generating additional carbon-induced climate challenges. Modifying process parameters, optimizing design, and employing high-performance working fluids are among the techniques offered by researchers for improving the thermal efficiency of heating and cooling systems. This study investigates the heat transfer enhancement of hybrid “Al2O3-Cu/water” nanofluids flowing in a two-dimensional channel with semicircle ribs. The novelty of this research is in employing semicircle ribs combined with hybrid nanofluids in turbulent flow regimes. A computer modeling approach using a finite volume approach with k-ω shear stress transport turbulence model was used in these simu

... Show More
View Publication
Scopus (14)
Crossref (18)
Scopus Clarivate Crossref
Publication Date
Sat Apr 01 2017
Journal Name
Applied Energy
Melting enhancement in triplex-tube latent heat energy storage system using nanoparticles-metal foam combination
...Show More Authors

View Publication
Scopus (292)
Crossref (292)
Scopus Clarivate Crossref
Publication Date
Thu Jan 06 2022
Journal Name
Iraqi National Journal Of Nursing Specialties
Effectiveness of an Instructional Program on Patientsꞌ Knowledge about Home Safety While Receiving Anti -Cancer Medications at Al- Karama Teaching Hospital in Al-Kut City
...Show More Authors

Objectives: To determine the effectiveness of the instructional program on patients’ knowledge about home safety while receiving anti-cancer treatment at  Al- Karama Teaching Hospital in Al-Kut City.

Methodology:   A quasi-experimental design is conducted through the application of a pre-test and post-test approach for the study and control groups from February 5th, 2020 to April 25th, 2020. A non–probability (purposive) sample of (50) patients treated at the Blood Disease and Oncology Center is selected and divided into two groups. Each group contains (25) patients as control and study groups. An instrument is constructed that is comprised of two parts; t

... Show More
View Publication Preview PDF
Publication Date
Sun Sep 27 2020
Journal Name
Iraqi National Journal Of Nursing Specialties
Effectiveness of an Instructional Program Concerning Non-Pharmacological Guideline on Controlling Essential Hypertension among Patients at AL-Sader Hospital in AL-Najaf AL-Ashraf City
...Show More Authors

Objective: The aims of present study to detect the effectiveness of instruction program of non-pharmacological guideline on blood pressure and laboratory test.

 

Methodology: A pre-experimental study was conducted in Al-Sader Teaching Hospital   from 8th of September 2019 to 25th of May 2020, in order to find out the effectiveness of instruction program concerning non-pharmacological guideline on controlling essential hypertension among patients. A non- probability (purposive sample) of 50 patients with essential hypertension is selected. Those patients are already diagnosed with Essential Hypertension

... Show More
View Publication Preview PDF
Publication Date
Mon Apr 25 2022
Journal Name
Diversity
Genetic Structure and Diversity of Native Tench (Tinca tinca L. 1758) Populations in Hungary—Establishment of Basic Knowledge Base for a Breeding Program
...Show More Authors

Tench is a cyprinid fish that has undergone human-induced translocations. The natural populations of the species are on the decline due to habitat loss and spawning grounds degradation. The genetic diversity of seven natural populations was investigated to establish the genetic knowledge base for successful conservation efforts and for selective breeding. Twelve microsatellite markers, the sequencing of a 615 bp section of mtDNA (Cytb) and PCR-RFLP analysis of two nuclear markers (Act) and (RpS7) were used to analyze the genetic variation and structure among 175 individuals. All microsatellite loci were found to have moderate levels of polymorphism. The pairwise Fst values between population pairings were moderate; the populations w

... Show More
View Publication
Scopus (7)
Crossref (7)
Scopus Clarivate Crossref
Publication Date
Wed Jan 01 2003
Journal Name
Turkish Journal Of Chemistry
Gas Chr Gas Chromatographic Separ aphic Separation of Phenol Deriv ation of Phenol Derivatives by Schiff- y SchiffBase Liquid Crystalline Stationary Phases
...Show More Authors

The chromatographic behaviour of liquid crystalline compounds benzylidene-p-aminobenzoic acid and 4-(p-methyl benzylidene)-p-aminobenzoic acid as stationary phases for the separation of dimethylphenol isomers was investigated. These isomers were analysed on benzylidene-p-aminobenzoic acid within a nematic range of 169-194 ◦C with a temperature interval of 5 ◦C. Better peak resolution was at a column temperature of 190 ◦C. The analysis was repeated on a 4-(p-methyl benzylidene)-p-aminobenzoic acid column at a nematic temperature of 256 ◦C, which represented the end of the nematic range, and gave the optimum peak resolution. It was found that isomer better separation was obtained at 20% loading for both liquid crystal materials. Other

... Show More