Background: Bone density is a major factor that affect mini implant primarily stability; no Iraqi studies have evaluated bone density related to mini-implant placement for orthodontic anchorage at age 13 -15 years. The present research aims to evaluate gender, side and site differences in the bone density at various orthodontic implant sites for the maxillary alveolar bone. Materials and methods: Twenty nine individuals (16 males and 13 females) had subjected to clinical examination, then 64-multislice computed tomography scan data were evaluated and bone density was measured in Hounsfield unit at 21 points (9 points for each side and 3 points between the right and left central incisors) . Results: The results obtained showed that there are no significant differences in bone density between males and females and between the left and right sides were found. There was no significant differences in bone density between the maxillary buccal cortical bone and the palatal cortical bone were generally except that at lateral incisor and canine point where the palatal side had higher bone density than buccal side. The mean bone density of the cancellous bone in the anterior part was higher than that in the posterior of the maxilla. Conclusions: When orthodontic, mini implant are indicated, no gender and side difference affect the success rate regarding bone density.
Objective: This study aims to assess the efficacy of CT-guided true-cut biopsy as a less invasive and cost-effective diagnostic technique for peripherally placed lung lesions.
Objective: This study aims to assess the efficacy of CT-guided true-cut biopsy as a less invasive and cost-effective diagnostic technique for peripherally placed lung lesions. Methods: fourty patients with solitary lung nodule were involved in this study, true cut biopsies under Ct guide was taken then processed for routine H&E staining. Results: different pathological features can be identified with different pathological features giving primary diagnostic screening for lung cancer Conclusion: CT guided thoracic lesion biopsy is very efficient, cost-effective and less invasive technique when compared with the thoracic surgery
Deficiencies in revenue-related accounting standards, including American accounting standards as well as international accounting standards, prompted the issuance of the International Financial Reporting Standard IFRS 15 "Revenue from contracts with customers" as part of the convergence plan between the FASB and the International Accounting Standards Board (IASB) according to the requirements of The joint venture between the two councils, whereby the standard aims to define the basis for reporting useful information to the users of the financial statements about the nature, amount, timing and uncertainty about the revenues and cash flows arising from a contract with the customer, The standard is base
... Show MoreThe current research aims to identify 1) the differences of emotional stability development level according to the variable of age; and 2) the differences of emotional stability development level according to the variable of gender (male, female). This study employed a descriptive approach, whereby a total of 165 primary and secondary school student was randomly selected from the directorate of AL -rusafa side (1st rusafa) of Baghdad province to constitute the sample of the study. The questionnaire was created based on the previous testes and studies that are relevant to emotional stability, and all its psychometrics features were examined. The researcher analyzed the data using SPSS statistic
... Show MoreResults of charge, neutron and matter densities and related form factors for one- proton halo nucleus 8B are presented using a two- frequency shell model approach. We choose a model space for the core of 7Be different from that of the extra one valence proton. One configuration is assumed for the outer proton to be in 1p1/2 - shell. The results of the matter density distributions are compared with those fitted to the experimental data. The calculated proton and matter density distributions of this exotic nucleus exhibit a long tail behavior, which is considered as a distinctive feature of halo nuclei. Elastic electron scattering form factors of this exotic nucleus are also studied. The effects of
... Show MoreKE Sharquie, AA Noaimi, GA Ibrahim, AS Al-Husseiny, Our Dermatology Online, 2016 - Cited by 3
The osseodensification (OD) drilling technique was suggested as an alveolar ridge expansion technique, so the aim of this prospective clinical study was to evaluate the amount of bone expansion obtained by the OD drilling technique and its effect on implant stability in patients with narrow alveolar ridges. The width of the alveolar ridge was measured at the crest before and after implant site preparation, whereas the implant stability was measured using Osstell Beacon implant stability quotient (ISQ). The ISQ values were recorded immediately postoperatively and after 16 weeks. Twenty-three patients were included; they received 40 implants. The mean (± standard deviation [SD]) amount of expansion was 1.29 (± 0.41) mm, and the difference b
... Show MoreThis research reports an error analysis of close-range measurements from a Stonex X300 laser scanner in order to address range uncertainty behavior based on indoor experiments under fixed environmental conditions. The analysis includes procedures for estimating the precision and accuracy of the observational errors estimated from the Stonex X300 observations and conducted at intervals of 5 m within a range of 5 to 30 m. The laser 3D point cloud data of the individual scans is analyzed following a roughness analysis prior to the implementation of a Levenberg–Marquardt iterative closest points (LM-ICP) registration. This leads to identifying the level of roughness that was encountered due to the range-finder’s limitations in close
... Show More