Background: Recent implant surgical approach aims to cause less trauma, invasiveness and pain as much as possible and to reduce patient and surgeon discomfort, time of surgery and time needed for functional implant loading. Flapless surgical techniques considered recently as one of the most popular techniques that may achieve these aims especially enhancing osseointegration and subsequently implant stability within less time than the traditional flapped surgical technique. So this study aimed to make a comparison between flapped and flapless surgical techniques in resulted implant stability according to resonance frequency analysis RFA and in duration of surgical operation. Materials and methods: A total of 26 patients with 41 implants (one implant in the study group failed so it was excluded from the statistical analysis) were randomized into two groups: control group which involved 20 implants inserted by conventional flapped surgical approach and study group which involved 20 implants inserted by flapless surgical approach. Estimation of alveolar bone was done for study group by bone (ridge) mapping procedure. Duration of surgical operation for each implant, Implant stability was measured at three time intervals (at surgery, two months and three months after surgery). Results: After three months interval of surgery the mean implant stability of the study (flapless) group achieved significant higher implant stability than control (flapped) group (P< 0.05) and the difference in measured implant stability was (5.05) implant stability quotient(ISQ). The time of surgical operation for implants in the study group significantly was less than that of control group (P< 0.01). Conclusions:implants placed with flapless surgical technique can produce high implant stability in shorter time and consume prominently shorter time for surgical operation compared to those placed with conventional flapped technique.
In this study, the turbulent buoyancy driven fluid flow and heat transfer in a differentially heated rectangular enclosure filled with water is quantified numerically. The two dimensional governing differential equations are discretized using the finite volume method. SIMPLE algorithm is employed to obtain stabilized solution for high Rayleigh numbers by a computational code written in FORTRAN language. A parametric study is undertaken and the effect of Rayleigh numbers (1010 to 1014), the aspect ratio (30, 40 and 50), and the tilt angle (10o to 170o ) on fluid flow and heat transfer are investigated. The results of the adopted model in the present work is compared with previously published results and a qualitative agreement and a good
... Show Morecontent Analysis for Some Type of Pillows used in Iraqi houses
The research aims to reveal the role of financial analysis in rationalizing the investor decision on the Iraqi stock Exchange market, by studying the relationship and impact techniques and methods of financial analysis on the decisions of investors in the market. The most important techniques and methods discussed in this study were: analysis (financial ratios analysis, comparison of financial statements analysis, cash flow statement analysis) for companies listed in the Iraqi stock Exchange market. The researcher adopted the analytical descriptive method which depends on the collection of data on the phenomenon and its interpretation. The questionnaire wa
... Show MoreThe use of non-parametric models and subsequent estimation methods requires that many of the initial conditions that must be met to represent those models of society under study are appropriate, prompting researchers to look for more flexible models, which are represented by non-parametric models
In this study, the most important and most widespread estimations of the estimation of the nonlinear regression function were investigated using Nadaraya-Watson and Regression Local Ploynomial, which are one of the types of non-linear
... Show MoreThe Present study investigated the drought in Iraq, by using the rainfall data which obtained from 39 meteorological stations for the past 30 years (1980-2010). The drought coefficient calculated on basis of the standard precipitation index (SPI) and then characteristics of drought magnitude, duration and intensity were analyzed. The correlation and regression between magnitude and duration of drought were obtained according the (SPI) index. The result shows that drought magnitude values were greater in the northeast region of Iraq.
Newspaper headlines are described as compressed and ambiguous pieces of discourse that represent the bodies of the articles. Their main function is to provide the readers with an informative message they would have no prior idea about. Ifantidou (2009) claims that the function of a headline is to get the readers’ attention rather than providing information because it does not have to represent the whole of the article it refers to. This paper aims at examining this hypothesis in relation to scientific news headlines reported by a number of news agencies. The paper follows Halliday (1967) information structure theory by applying it on ten selected headlines; each two headlines represent one scientific discovery reported by different new
... Show MoreFoot and ankle movements are essential in various activities like walking, running, and balance, where the mechanics of these movements are affected by the muscles around the ankle joint [1,2]. In this study, the correlations between isometric ankle torque and muscle activity of the tibialis anterior (TA) and gastrocnemius (GAS) in the course of dorsiflexion and plantarflexion was investigated. Eight healthy participants were enrolled for the study, where the ankle torque and surface Electromyography (sEMG) of the main flexors were measured and analyzed. The results showed that ankle torque is higher in plantarflexion than dorsiflexion. In addition, the TA has greater muscle activity during dorsiflexion, while the GAS presents higher ac
... Show MoreShell-and-double concentric tube heat exchanger is one of the new designs that enhance the heat transfer process. Entransy dissipation is a recent development that incorporates thermodynamics in the design and optimization of heat exchangers. In this paper the concept of entransy dissipation is related to the shell-and-double concentric tube heat exchanger for the first time, where the experiments were conducted using hot oil with temperature of 80, 100 and 120°C, flow rate of cold water was 0.667, 1, and 1.334 kg/m3 respectively and the temperature of inlet cold water was 20°C. The entransy dissipation rate due to heat transfer and to fluid friction or pressure drop was studied.
