Background: Recent implant surgical approach aims to cause less trauma, invasiveness and pain as much as possible and to reduce patient and surgeon discomfort, time of surgery and time needed for functional implant loading. Flapless surgical techniques considered recently as one of the most popular techniques that may achieve these aims especially enhancing osseointegration and subsequently implant stability within less time than the traditional flapped surgical technique. So this study aimed to make a comparison between flapped and flapless surgical techniques in resulted implant stability according to resonance frequency analysis RFA and in duration of surgical operation. Materials and methods: A total of 26 patients with 41 implants (one implant in the study group failed so it was excluded from the statistical analysis) were randomized into two groups: control group which involved 20 implants inserted by conventional flapped surgical approach and study group which involved 20 implants inserted by flapless surgical approach. Estimation of alveolar bone was done for study group by bone (ridge) mapping procedure. Duration of surgical operation for each implant, Implant stability was measured at three time intervals (at surgery, two months and three months after surgery). Results: After three months interval of surgery the mean implant stability of the study (flapless) group achieved significant higher implant stability than control (flapped) group (P< 0.05) and the difference in measured implant stability was (5.05) implant stability quotient(ISQ). The time of surgical operation for implants in the study group significantly was less than that of control group (P< 0.01). Conclusions:implants placed with flapless surgical technique can produce high implant stability in shorter time and consume prominently shorter time for surgical operation compared to those placed with conventional flapped technique.
This study aims to fabricate and assess the β-tricalcium phosphate (β-TCP) bioactive ceramic coat layer on bioinert ceramic zirconia implants through the direct laser melting technique by applying a long-pulsed Nd:YAG laser of 1064 nm. Surface morphologies, adherence, and structural change in the coatings were evaluated by optical microscopy, field emission scanning electron microscope, hardness, and x-ray diffractometer. The elastic modulus (EM) of the coating was also determined using the nanoindentation test. The quality of the coating was improved when the laser power was 90 W with a decrease in the scan speed to 4 mm s−1. The chemical composition of the coat was maintained after laser processing; also, the Energy Dispersive
... Show MoreBackground: It has been well known that the success of mandibular implant- retained overdenture heavily depends on initial stability, retention and long term osseointegration this is might be due to optimal stresses distribution in surrounding bones. Types of mandibular implant- retained overdenture anchorage system and number of dental implants play an important role in stresses distribution at the implant-bone interface. It is necessary to keep the stresses below the physiologic tolerance level of the bone .since. And it is difficult to measure these stresses around bone in vivo. In the present study, finite element analysis used to study the stresses distribution around dental implant supporting Mandible implant retained overdenture Mate
... Show MoreThrust blocks and restraint joints are the two most popular methods of counteracting the thrust force that generated at pipe fittings (bends, Tee, wye, reducers, dead ends, etc…). Both systems perform the same function, which is to prevent the joints from separating from the pipes. The aim of the study is to review previous studies and scientific theories related to the study and design of thrust blocks and restraint joints to study the behavior of both systems under thrust force and to study the factors and variables that affect the behavior of these systems. The behavior of both systems must be studied because they cannot be abandoned, as each system has conditions whose use is more feasible, scientific, and economic
... Show MoreOne of the critical factors for dental implant success is accurate clinical and radiological assessment. Cone-beam computed tomography systems (CBCT) allow surgeons to determine the quality and quantity before surgery, aiding in treatment planning. This study highlights the importance of such an assessment Materials and Methods A total of 40 patients were referred to CBCT scanning for pre-dental implant assessment in the Oral and Maxillofacial Radiology department at Al-Shaheed Gazi Al Hariri Hospital from 2021 to 2022. The patients were between 18 and 50 years old. All data were analyzed with on-demand 3D software (Kavo OP 3D: Cone Beam 3D imaging Germany). Results: Regarding the ridge shape: In the upper anterior and posterior regions, th
... Show MoreAddressed the problem of the research is marked (experimentation in caves fee) concept and its role in experimentation deviate Display Num formal charges caves. The search came in four sections: general framework for research and identified the research problem and the need for him. With an indication of the importance of his presence. Then specify the search for the goals of (revealed the nature and role of experimentation in determining the nature of Manifesting fee documented on the walls of caves), followed by the establishment of the three search limits (objectivity, the temporal and spatial) were then determine the terms related to the title. Then provide the theoretical framework and indicators that resulted from academic theorizi
... Show MoreCOVID-19 is a coronavirus disease caused by the severe acute respiratory syndrome. According to the World Health Organization (WHO), coronavirus-2 (SARS-CoV-2) was responsible for 87,747,940 recorded infections and 1,891,352 confirmed deaths as of January 9, 2021. Antibodies that target the Sprotein are efficient in neutralizing the virus. Methodology: 180 samples were collected from clinical sources (Blood and Nasopharyngeal swabs) and from different ages and genders at diverse hospitals in Baghdad / IRAQ between November 5, 2021, to January 20, 2022. All samples were confirmed infected with COVID-19 disease by RT-PCR technique. Haematology analysis and blood group were done for all samples, and Enzyme-Linked Immunosorbent Assay used an Ig
... Show MoreMost researchers concentrate their studies on the design, stress and pressure distributions of the prosthetic socket. A little attention is considered for the stiffness of the various materials of the prosthetic sockets. Prosthetic laminated sockets in Iraq are costly to be manufactured while polypropylene socket is relatively cheap in comparing with the laminates.
Experimental study is conducted to compare the stiffness of five prosthetic sockets made of different materials. Compression, three point flexural and tensile tests are implemented by the Testometric machine. The laminate sockets give better results in compression than polypropylene. Polypropylene gives good results in bending compared with the laminate sockets. When t
... Show MoreBackground: Removing dental plaque is important to maintain a good oral hygiene and prevent periodontal disease; this could not be accomplished by the use of toothbrush alone, it needs the help of interdental aids or intra-oral irrigator devices. The aim of this study was to compare the effect of using Waterpik flosser as adjunct to tooth brushing than using the dental floss with the brushing. Materials and methods: A single blind, six weeks study included 45 subjects divided into three groups of 15 subjects at each group. Group B (brushing) was instructed to use the toothbrush only, group BF (brushing & flossing) was instructed to use dental floss and tooth brushing while group BW (brushing and Waterpik flosser) was instructed to use Water
... Show More