Back ground: Oral lichen planus is a chronic inflammatory disease that affects the mucous membrane of the mouth. Several researchers suggest that oxidative stress is implicated in the pathogenesis of this disorder. It has been hypothesized that melatonin is powerful anti-oxidants and can easily cross the cell membrane and is considered a free radical scavenger of Hydroxid, Oxygen and Nitrogen dioxide, cortisol as a stress hormone and the immunoglobulin A as first line of defense and protection to the mucous membrane of the mouth are interrelated factors for the emergence of oral lichen planus. Aim of this study was to evaluate the level of melatonin, Cortisol and IgA in saliva of patients with oral lichen planus lesions in comparison with participants with normal oral mucosa. Materials and methods: In this study seventy five subjects with age 18 and over were included. The subjects were divided into two groups; control group, this group comprised of 41 subjects with normal oral mucosa and the study group, which comprised of 34 subjects with clinically and histopathologically diagnosed oral lichen planus lesion. The samples were selected from patients attending College of Dentistry/University of Baghdad and cases that recruited to the AL-Emmam Ali hospital / in Baghdad /Dermatology Department. Samples collection started from 2/ may 2013 to 23/ January 2014.Saliva samples were collected between 10-12 Am. High performance chromatography (HPLC) analyzing technique was used for estimating the salivary melatonin and cortisol level. IgA level was measured by ELIZA method. Results: The mean salivary melatonin level in patients with oral lichen planus was 4.786 µg/ml and the mean saliva melatonin level in normal person was 8.759 µg/ml. significant difference (p<0.01) was observed in the salivary melatonin levels between the study and control group. The mean salivary cortisol level in patients with OLP was 0.730 µg / ml and the mean saliva cortisol level in normal persons was 0.165 µg/ml. significant difference (p<0.01) was observed in the salivary cortisol levels between the study and control, group. The mean salivary IgA level in patients with OLP was 221.4 µg/ml and the mean saliva IgA level in normal person was 125.8 µg/ml. There was a high significant difference (p<0.01) the study and control groups. Conclusions: The level of salivary melatonin was lower in patients with oral lichen planus, however cortisol and IgA was higher when comparing the salivary level with that of the control groups.
In this research, the removal of cadmium (Cd) from simulated wastewater was investigated by using a fixed bed bio-electrochemical reactor. The effects of the main controlling factors on the performance of the removal process such as applied cell voltage, initial Cd concentration, pH of the catholyte, and the mesh number of the cathode were investigated. The results showed that the applied cell voltage had the main impact on the removal efficiency of cadmium where increasing the applied voltage led to higher removal efficiency. Meanwhile increasing the applied voltage was found to be given lower current efficiency and higher energy consumption. No significant effect of initial Cd concentration on the removal efficiency of cadmium b
... Show MoreIn this research, deposition of titanium oxide (TiO2) and vanadium oxide (V2O5) thin film in different mixing percentage (0, 25 ,50, 75 and100)% on the substrate of glass .The coating thickness was ( 50 nm ).
In this research contact angle was measured and the effect of weather conditions. Results showed that the value of the contact angle of the prepared films reached its highest value at 50% (TiO2+V2O5) was 160º.
The results showed that the optical transmittance of TiO2 and V2O5 thin film decrease with increasing the deposition angle and decrease with increasing V2O5 pro
... Show MoreIn this work, an experimental study has been done to expect the heat characteristics and performance of the forced-convection from a heated horizontal rectangular fins array to air inside a rectangular cross-section duct. Three several configurations of rectangular fins array have been employed. One configuration without notches and perforations (solid) and two configurations with combination of rectangular-notches and circular-perforations for two various area removal percentages from fins namely 18% notches-9% perforations and 9% notches-18% perforations are utilized. The rectangular fins dimensions and fins number are kept constant. The fins array is heated electrically from the base
... Show MoreLeaching process applied for the extraction of bio active compounds from dried roots of (Elecampane) Inula helenium. Ethanol, hexane and distillated water were used as solvents. Roots were soaked with ethanol (5% w/v) with various concentration of ethanol (30 to 98%) at one day to know effect concentration of the solvent with concentration of bio active compound in Inula helenium. The same procedure was done using hexane as solvent. Also distilled water was used as solvent for extraction 5%(w/v) where plant material was soaked in water at different temperatures (25, 40, 65, 80, and 90) C. In all solvents undertaken, the effect of time duration on active ingredient (Thymol, Isoalatolactone, Alatolactone, 10-isobutyryl-oxy 8-9-epoxy thymol is
... Show MoreImpact strength of self-compacted concrete is a field of interest, mostly when the concrete is produced from sustainable materials. This research's main objective is to clarify the ability to use two types of Portland limestone cement (Karasta and Tasluja) in self compacted concrete under impact loading, further to the economic and environmental benefits of the limestone cement. The impact loading was applied by a low-speed test, using the drop ball on concrete. Moreover, the study reveals the resistance of the grids reinforced concrete to impact loading by using polymer grid, and steel grid reinforced concrete slabs. Mixes reinforced by steel mesh had the highest results, indicating that the steel mesh was more robust because it had
... Show MoreThe aim of this research is to assess the validity of Detailed Micro-Modeling (DMM) as a numerical model for masonry analysis. To achieve this aim, a set of load-displacement curves obtained based on both numerical simulation and experimental results of clay masonry prisms loaded by a vertical load. The finite element method was implemented in DMM for analysis of the experimental clay masonry prism. The finite element software ABAQUS with implicit solver was used to model and analyze the clay masonry prism subjected to a vertical load. The load-displacement relationship of numerical model was found in good agreement with those drawn from experimental results. Evidence shows that load-displacement curvefound from the finite element m
... Show MoreThis paper proposes a novel finite-time generalized proportional integral observer (FTGPIO) based a sliding mode control (SMC) scheme for the tracking control problem of high order uncertain systems subject to fast time-varying disturbances. For this purpose, the construction of the controller consists of two consecutive steps. First, the novel FTGPIO is designed to observe unmeasurable plant dynamics states and disturbance with its higher time derivatives in finite time rather than infinite time as in the standard GPIO. In the FTGPO estimator, the finite time convergence rate of estimations is well achieved, whereas the convergence rate of estimations by classical GPIO is asymptotic and slow. Secondly, on the basis of the finite and fast e
... Show MoreIn this paper, a numerical model for fluid-structure interaction (FSI) analysis is developed for investigating the aeroelastic response of a single wind turbine blade. The Blade Element Momentum (BEM) theory was adopted to calculate the aerodynamic forces considering the effects of wind shear and tower shadow. The wind turbine blade was modeled as a rotating cantilever beam discretized using Finite Element Method (FEM) to analyze the deformation and vibration of the blade. The aeroelastic response of the blade was obtained by coupling these aerodynamic and structural models using a coupled BEM-FEM program written in MATLAB. The governing FSI equations of motion are iteratively calculated at each time step, through exchanging data between
... Show More