Background: The isthmus is a difficult area in the root canal complex to manage. The research aimed to evaluate the efficiency of three different obturation techniques (lateral condensation, EandQ (thermoplasticized gutta percha system) and Soft Core (thermoplasticized core carrier gutta percha system)) to obturate the isthmus area of roots prepared by two different instrumentation techniques (rotary ProTaper universal and ProTaper Next systems). Material and method: Sixty freshly extracted teeth were randomly divided into two main groups (A and B) of 30 teeth each. Group A was prepared by rotary ProTaper Universal whereas group B was prepared by ProTaper Next system. Each main group was then randomly subdivided into three subgroups of 10 teeth each, to be obturated with the three obturation techniques. All specimens were then placed in cold cure acrylic mold just from the side of the crown leaving the root unmolded to facilitate the sectioning process, then three sections were obtained from each specimen by using microtome at 2, 6 and 10 mm from the apex. Each section was viewed under stereomicroscope(40X) and imaged with digital camera(4X). Each image was managed with image J program to calculate the surface area of the whole isthmus and that of the gutta percha and/or sealer extended into the isthmus so the collected data represented the percentage of extension degree of gutta percha and /or sealer into the isthmus(EDGS). Results: The highest mean value of (EDGS) was evident with Soft Core technique in the apical area and was significantly higher than that of the EandQ and lateral condensation techniques. Conclusion: Under the conditions of this study, Soft Core system showed a higher efficiency in obturating the isthmus area than the other obturation techniques.
Background: White spot lesion considered as irreversible tooth demineralization presenting challenge to orthodontists during treatment schedules, fluoride was the most successfully used measure to overcome this challenge. Materials and method: A total of forty sound human permanent premolars were used in the present study and categorized into four groups, in one group the teeth were bonded with stainless steel brackets using Resin-modified glass ionomer cement (RMGIC) and the other three groups the teeth were bonded with light cured composite Resilience® (Ortho technology Co., USA). Group A; Acidulated phosphate fluoride (APF) topical gel (Mfg by DEEPAK PRODUCTS, INC, USA), fluoride ion 1.23% applied on examine area for four minute. Gro
... Show MoreThe research to knows some biomechanics variables in different spots with and without players in basketball youth players and analysis by using destructive method in surfing study and the research were applied for jump shoot from one of basketball players in ( middle , left , right ) in side zone and out of zone also from three point shoot with and without defense and we depend on successful shoot on analyze .The results and conclusions that center of weight of the player on standby on high and knee angel and hips were more wide also the two angle of wrist , elbow on start of shooting be more wide with defender more than without defender .the maximum high center of weight and shooting angle and ball entrance being less degree with defender
... Show MoreIn current study a computation fluid dynamic (CFD) technique was used to investigate the effect of groynes shape and spacing on the scour pattern and the maximum scour depth in open channel flow. CFD model have been validated throughout comparing the numerical results with three previous experimental studies for a single groyne located in open channel with three different shapes (L, quadrant, and parabola shapes). The comparison revealed very good agreement between numerical results of the maximum scour depth with the results of all experimental models. Moreover, investigations of the effect of multi-groynes (three groynes and four groynes) arranged in parallel with constant spacing and also with variable spacing have been done, the
... Show MoreTo develop a petrol engine so that it works under the bi-engine pattern (producer gas-petrol) without any additional engine modifications, a single-point injection method inside the intake manifold is a simple and inexpensive method. Still, it leads to poor mixing performance between the air and producer gas. This deficiency can cause unsatisfactory engine performance and high exhaust emissions. In order to improve the mixing inside the intake manifold, nine separate cases were modelled to evaluate the impact of the position and angle orientation inside the intake manifold on the uniformity and spread of the mixture under AFR=2.07. A petrol engine (1.6 L), the maximum engine speed (8000 rpm), and bi-engine mode (petrol-producer ga
... Show MoreThis research a mining at evaluation the efficiency of the nursing performance depended on standards of W.H.O. via application standards of W.H.O on the nursing personnel in medical city office, in light of it, it has design world evaluation list, and a sample was chosen from the nursing personnel in given researched the organization whom they are evaluated according to the standards of W.H.O for the nursing performance included of ten standards, divided in to 45 question , besides the evaluation list, the researcher get assistance of some tools of collection information via actual checking and personal interviews, a number of statistical means were used to manipulate t
... Show MoreBackground: The microhardness of a composite resin is a vital parameter that is used to determine its clinical behavior. Measuring the microhardness of a composite resin has been used as an indirect method to assess its degree of conversion and extent of polymerization. The purpose of this in vitro study was to evaluate the effect of three curing distances (0, 2, and 4 mm) on the microhardness of the top and bottom surfaces of three types of flowable bulk-fill composite resins (smart dentin replacement, Opus bulk fill flow, and Tetric N). Material and method: Sixty-three specimens from the three types of composite resins (n=21) were fabricated using Teflon mold with a 4mm depth and a 5 mm internal diameter and cured for 20 seconds. For e
... Show MoreBackground and objectives: This study aimed at testing the effect of plastic sleeve or barrier, used to cover the guide of the light cure unit to prevent cross-infection, on the shear bond strength and site of bond failure of stainless steel and ceramic orthodontic brackets. Materials and methods: Forty orthodontic brackets; twenty stainless steel and twenty ceramic brackets bonded to forty extracted human maxillary first premolars using light cure adhesive cured with and without the use of a protective plastic barrier on the guide. Comparing the effect of this barrier on the shear bond strength and adhesive remnant index was performed using an independent t-test and Chi-square test. Results: The protective barrier had decreased the shear b
... Show MoreOne hundred isolates of Pseudomonas aeruginosa were obtained from patients admitted to Baghdad hospitals, Iraq during the period between May 2018 until July 2018. These isolates were distributed as 15 isolates from blood, 25 isolates from urinary tract infections, 10 isolates from sputum, 12 isolates from wounds, 15 isolates from ear infections, 15 isolates from bronchial wash of patients suffering from respiratory tract infections in addition to 8 isolates from cystic fibrosis patients. The isolates were initially identified by culturing on MacConkey agar, blood agar and P. aeruginosa agar then diagnosed by performing some morphological and biochemical tests. The second diagnosis was done by API 20E system followed by Vitek 2 compact syste
... Show MoreIntroduction: This study aimed to assess the color change of human teeth with artificial enamel white spot lesions (WSLs) after sandblasting with bioactive glass, resin infiltration, and microabrasion and to test color stability after pH cycling. Methods: Fifty extracted human mandibular first molars were randomly assigned into five groups: Sound, WSLs (untreated), and WSLs sandblasted with bioactive glass (Sylc), WSLs treated by resin infiltration (ICON), and WSLs treated by microabrasion (Opalustre), respectively. All specimens underwent a pH cycling procedure. The color parameters for each specimen were assessed using an Easyshade dental spectrophotometer at different time stages then the color changes (ΔE) were calculated. Results: The
... Show More