Preferred Language
Articles
/
jbcd-1137
The Effect of Ceramic Thickness and Number of Firings on the Color of Two All-Ceramic Systems Measured by Spectrophotometer
...Show More Authors

Background: This in vitro study was carried out to evaluate the effects of various veneering dentin ceramic thicknesses and repeated firings on the color of lithium disilicate glass-ceramic (IPS e.max Press) and zirconium-oxide (IPS ZirCAD) all-ceramic systems, measured by clinical spectrophotometers (Easyshade Advance 4.0) . Materials and methods: The 72specimens cube-shaped have the dimension of about 11 mm in width, 14 mm in length, 1mm in thickness, these cores divided into 3 groups according to the type of material each group have (24)core specimens. Each group had been divided into three sub-groups (each having 8 specimens) according to veneering with dentin ceramic thicknesses: as 0.5, 1, or 2 mm (n=8). IPS e.max press and ZirCAD cores group had been veneered with IPS e.max Ceram dentin ceramic shade A2 according to manufacturer’s instructions and the metal group had been veneered with IPS classic dentine ceramic with shade A2 according to manufacturer’s instructions. Repeat firings (3, 5 and 7 times) had been applied on all the specimens. Color differences among ceramic specimens had been measured using a clinical spectrophotometer (VITA Easyshade); the color data had been expressed according the Vita Classic shade guide. Results: The shade of all specimens had been compared inside the subgroups and with the main groups. The percentage of color agreement among the subgroups showed the color of all ceramic systems had been affecting by firing interval, the ceramic thickness and brand of ceramic. The number firings intervals applied on the all ceramic system has a significant effect on the final color, the increase of firing number change the color to a darker and reddish color. The 5th firing interval is the point at which the major color changes happened (darker shade), and in next interval (7th firing) less color changes happened. The thickness of veneering ceramic affected the color significantly. The 0.5 mm specimens in all groups showed the highest percentage of agreement (less color changes) after firing intervals, then the 1mm came and the least percentage of agreement ( highest color changes ) was the 2 mm specimens. The Brand of veneering ceramic and the type of core record a significance difference in color changes when exposed to firing heat. Conclusion: With limit of this study, the final color of the all ceramic system definitely affected by the number of firing cycle exposed to, and the veneering ceramic thickness have a clear effect on the final shade of the all ceramic tested.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Dec 25 2019
Journal Name
International Journal Of Corrosion And Scale Inhibition
Evaluation and characterization of the symbiotic effect of benzylidene derivative with titanium dioxide nanoparticles on the inhibition of the chemical corrosion of mild steel
...Show More Authors

A new benzylidene derivative, namely N-benzylidene-5-phenyl-1,3,4-thiadiazol-2-amine (BPTA), has been synthesized and instrumentally confirmed with Elemental Analysis (CHN), Nuclear Magnetic Resonance (NMR), and Fourier Transform Infrared Spectroscopy (FT-IR). Titanium Dioxide (TiO2) nanoparticles (NPs) were synthesized and characterized by X-ray. The mutualistic complementary dependence of BPTA with TiO2 nanoparticles as anti-corrosive inhibitor on mild steel (MS) in 1.0 M hydrochloric acid has been tested at various concentrations and various temperatures. The methodological work was achieved by gravimetric measurement methods complemented with surface analysis. The synthesized inhibitor concentrations were 0.1 mM to 0.5 mM and the temper

... Show More
Preview PDF
Scopus (80)
Scopus
Publication Date
Fri Jul 01 2022
Journal Name
Translation & Linguistics
TO THE QUESTION ABOUT THE USE OF METAPHORS IN THE CREATION OF ART (ON THE EXAMPLE OF THE STORY BY D. RUBINA "YOU AND ME UNDER THE PEACH CLOUDS")
...Show More Authors

The article reflects the results of the analysis of the use of metaphors when creating the image of the main character of the story by D. Rubina "You and me under the peach clouds" - a pet, a dog named Kondraty. Through metaphorization, the image of the dog is filled by the author with purely human qualities, thus passing into the category of a full member of the family. The article is a continuation of the study of the work of D. I. Rubina.

Publication Date
Fri Mar 01 2019
Journal Name
Iraqi Journal Of Physics
Study the effect of Ag nanoparticles and ZnO nanoparticles at different concentrations on the viscosity and surface tension of Polyacrylamide solutions
...Show More Authors

Polyacrylamide Solutions of different concentrations (0.2, 0.4, 0.6, 0.8, 1.0 %) of Ag nanoparticles and ZnO nanoparticles were prepared, the viscosities and surface tension were measured for all solutions, where measurements indicated an increase in these properties with increased concentration, where the relative viscosity of polyacrylamide/zinc nanoparticles increased from 1.275 to 2.243, and the relative viscosity of polyacrylamide/silver nanoparticles increased from 1.178 to 1.934. Viscosity is significant parameters during electrospinning process. While the surface tension of the polyacrylamide/zinc nanoparticles has changed from 0.0343 Nm-1 to .0.0.0 Nm-1 and changed from .0.000Nm-1 to.0.0.0 Nm-1. Also the constants KH and KK were

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sun Jun 30 2019
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Evaluation the Effect of Velocity and Temperature on the Corrosion Rate of Crude Oil Pipeline in the Presence of CO2/H2S Dissolved Gases
...Show More Authors

In this paper investigate the influences of dissolved CO2/H2S gases, crude oil velocity and temperature on the rate of corrosion of crude oil transmission pipelines of Maysan oil fields southern Iraq. The Potentiostatic corrosion test technique was conducted into two types of carbon steel pipeline (materials API 5L X60 and API 5L X80). The computer software ECE electronic corrosion engineer was used to predict the influences of CO2 partial pressure, the composition of crude oil, flow velocity of crude oil and percentage of material elements of carbon steel on the rate of corrosion. As a result, the carbon steel API 5L X80 indicates good and appropriate resistance to corrosion compared to carbon steel API

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Tue Jan 01 2013
Journal Name
العلوم التربوية والنفسية
The effect of a strategy for creative thinking on the achievement of chemistry and the reading comprehension ability of secondary school female students
...Show More Authors

Preview PDF
Publication Date
Wed Aug 17 2022
Journal Name
Aip Conference Proceedings
The effect of using Gaussian, Kurtosis and LogCosh as kernels in ICA on the satellite classification accuracy
...Show More Authors

This study focusses on the effect of using ICA transform on the classification accuracy of satellite images using the maximum likelihood classifier. The study area represents an agricultural area north of the capital Baghdad - Iraq, as it was captured by the Landsat 8 satellite on 12 January 2021, where the bands of the OLI sensor were used. A field visit was made to a variety of classes that represent the landcover of the study area and the geographical location of these classes was recorded. Gaussian, Kurtosis, and LogCosh kernels were used to perform the ICA transform of the OLI Landsat 8 image. Different training sets were made for each of the ICA and Landsat 8 images separately that used in the classification phase, and used to calcula

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Tue Jun 30 2015
Journal Name
Al-khwarizmi Engineering Journal
Studying and Modeling the Effect of Graphite Powder Mixing Electrical Discharge Machining on the Main Process Characteristics
...Show More Authors

Abstract

This paper concerned with study the effect of a graphite micro powder mixed in the kerosene dielectric fluid during powder mixing electric discharge machining (PMEDM) of high carbon high chromium AISI D2 steel. The type of electrode (copper and graphite), the pulse current and the pulse-on time and mixing powder in kerosene dielectric fluid are taken as the process main input parameters. The material removal rate MRR, the tool wear ratio TWR and the work piece surface roughness (SR) are taken as output parameters to measure the process performance. The experiments are planned using response surface methodology (RSM) design procedure. Empirical models are developed for MRR, TWR and SR, using the analysis

... Show More
View Publication Preview PDF
Publication Date
Thu Jun 30 2022
Journal Name
Pakistan Journal Of Medical And Health Sciences
The Effect of Hand Blood Flow on the Peripheral Fingertip Plethysmographic Waveforms Morphology and Pulse Wave Velocity
...Show More Authors

Photoplethysmography (PPG) is a non-invasive optical technique that employs variations in light absorption produced by alteration in the blood volume in capillaries at the skin during the cardiac cycle. This study aims to understand factors related to PPG morphology; a hand-elevation, the study has modified blood flow to and from the finger was conducted in the laboratory. It is widely established that the position of the limb relative to the heart has an effect on blood flow in arteries and venous. Peripheral digital pulse wave (DPW) signals were obtained from 15 healthy volunteer participants during hand-elevation, and hand-lowering techniques wherein the right hand was lifted and lowered relative to heart level, while the left h

... Show More
View Publication
Crossref (1)
Crossref
Publication Date
Mon Jan 30 2023
Journal Name
Iraqi Journal Of Science
Study the Effect of Oxygen on Coronene Electronic and Spectroscopic Properties via the Density Functional Theory (DFT)
...Show More Authors

    The electronic properties (such as energy gap HOMO levels. LUMO levels, density of state and density of bonds in addition to spectroscopic properties like IR spectra, Raman spectra, force constant and reduced masses as a function of frequency) of coronene C24 and reduced graphene oxide C24OX , where x=1-5, were studied.. The  methodology employed was  Density Functional Theory (DFT) with Hybrid function B3LYP and 6-311G** basis sets. The energy gap was calculated for C24 to be 3.5 eV and for C24Ox was from 0.89 to 1.6862 eV  for x=1-5 ,respectively.   These energy gaps values are comparable to the measured gap of Graphene (1-2.2 eV). The spectroscopic properties were  compared with experimental measurements, specificall

... Show More
View Publication
Scopus (2)
Crossref (2)
Scopus Crossref
Publication Date
Thu Sep 01 2016
Journal Name
Journal Of Engineering
The Effect of Vehicle Body Shapes on the Near Wake Region and Drag Coefficient: A Numerical Study
...Show More Authors

The purpose of this paper is to gain a good understanding about wake region behind the car body due to the aerodynamic effect when the air flows over the road vehicle during its movement. The main goal of this study is to discuss the effect of the geometry on the wake region and the aerodynamic drag coefficient. Results will be achieved by using two different shapes, which are the fastback and the notchback. The study will be implemented by the Computational Fluid Dynamic (CFD) by using STAR-CCM+® software for the simulation. This study investigates the steady turbulent flow using k-epsilon turbulence model. The results obtained from the simulation show that the region of the air separation behind the vehicle

... Show More
View Publication Preview PDF