Preferred Language
Articles
/
jbcd-1136
An Evaluation of Gutta-Percha Penetration Depth into Simulated Lateral Canals by Using Three Different Obturation Techniques (A Comparative Study)
...Show More Authors

Background:sThe aims of this study were to evaluate and compare the ability of three different techniques to obdurate simulated lateral canals, evaluate the effect of the main canal curvature on obturation of lateral canals and compare the gutta-percha penetration between coronal and apical lateral canals. Materials and methods: Resin blocks with 30 straight and 30 curved were used in this study. Each canal has two parallel lateral canals. The main canal has 0.3 mm apical diameter and 0.04 taper. The canals were divided into six groups according to canal curvature and obturation techniques used (n=10): Groups C1 and C2: straight and curved canals obturated with continuous wave technique using E&Q masterTM system. Groups O1 and O2: straight and curved canals obturated with Obtura II. Groups T1 and T2: straight and curved canals obturated with Thermafil obturators. Soapy water was used to simulate sealer in all obturations performed. The depth of gutta-percha penetration into lateral canals was measured using computerized stereomicroscope. Results: There were very highly significant differences between the obturation techniques at each lateral canal level in both straight and curved canals. Continuous wave using E&Q masterTM system exhibited the greatest gutta-percha penetration into lateral canals with very highly significant difference from both other techniques at majority of lateral canals. There was non- significant difference between Thermafil and Obtura II except at coronal lateral canal of straight main canals where the difference was very highly significant. The gutta-percha depth was greater in coronal than apical lateral canals in all groups of both straight and curved canals, and gutta-percha depth was greater in straight than in curved canals within each obturation technique. Conclusion: This study showed that all the three obturation techniques used were able to obturate simulated lateral canals with the continuous wave technique being the best. Gutta-percha depth was less in the apical than the coronal lateral canals. Canal curvature can influence the gutta-percha depth.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Aug 28 2019
Journal Name
Journal Of Engineering
Evaluation of Heavy Metals Content in Simulated Solid Waste Food Compost
...Show More Authors

Composting is one of the solid waste management (SWM) methods where the organic component decomposed biologically under controlled conditions. In this study, a 0.166 m3 bioreactor tank was designed to compose 59.2Kg of simulated common municipal solid food waste having a bulk density, organic matter, organic carbon, pH, nitrogen content, C/N and nitrification index (NH4-N/ NO3-N) of 536.62 kg/m3, 62.34%, 34.76%, 6.53, 1.86%, 23 and 0.34 respectively. The bioreactor operated aerobically for 30 days, and anaerobically for 70 days, until the end of the composting process. Results proved that the composting process could reduce the mass of the waste by 69%.  Nitrogen content,

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Fri Sep 26 2025
Journal Name
Journal Of Baghdad College Of Dentistry
The Marginal Fitness of CAD/CAM All Ceramic Crowns Constructed by Two Typesof Direct Digitization Techniques (An In Vitro Study)
...Show More Authors

Background: In capturing a negative image, the digital impression secures a digital record for the purposeof designing and creating restorations. The introduction of scanning system presents a paradigm shift in the way of the dental impression procedure and encourages the accuracy of obtained restoration especially in the marginal area as a result of producing accurate final impression The digital system offers many advantages over the Conventional method.. The objective of this present in vitro study was to evaluate the marginal fitness of all ceramic crowns fabricated by direct digital scanning of the prepared tooth using two types of intra-oral cameras (Bluecam camera with strip light projection technique and Omnicam camera with video sa

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Wed Jan 01 2014
Journal Name
International Journal Of Computer Applications
Mobile Position Estimation based on Three Angles of Arrival using an Interpolative Neural Network
...Show More Authors

In this paper, the memorization capability of a multilayer interpolative neural network is exploited to estimate a mobile position based on three angles of arrival. The neural network is trained with ideal angles-position patterns distributed uniformly throughout the region. This approach is compared with two other analytical methods, the average-position method which relies on finding the average position of the vertices of the uncertainty triangular region and the optimal position method which relies on finding the nearest ideal angles-position pattern to the measured angles. Simulation results based on estimations of the mobile position of particles moving along a nonlinear path show that the interpolative neural network approach outperf

... Show More
Publication Date
Sun Apr 01 2018
Journal Name
Journal Of Economics And Administrative Sciences
Solving a three dimensional transportation problem using linear programming
...Show More Authors

Transport is a problem and one of the most important mathematical methods that help in making the right decision for the transfer of goods from sources of supply to demand centers and the lowest possible costs, In this research, the mathematical model of the three-dimensional transport problem in which the transport of goods is not homogeneous was constructed. The simplex programming method was used to solve the problem of transporting the three food products (rice, oil, paste) from warehouses to the student areas in Baghdad, This model proved its efficiency in reducing the total transport costs of the three products. After the model was solved in (Winqsb) program, the results showed that the total cost of transportation is (269,

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Sep 26 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Evaluation of frictional forces generated by different brackets and orthodontic wires
...Show More Authors

Background: Sliding mechanics is widely used during orthodontic treatment. One of the disadvantages of this mechanics is the friction generated at the bracket/archwire interface, which may reduce the amount of desired orthodontic movement obtained. The aim of the present in vitro study was to evaluate and compare the static frictional forces produced by two passive self-ligating brackets stainless-steel and hybrid and two conventional brackets stainless-steel and monocrystal ligated with stainless-steel ligature wire at two degrees of torque(zero and twenty) under dry condition. Materials and method: One hundred and sixty brackets were used in this study divided into four groups each group consisted of forty brackets these are: Two self-li

... Show More
View Publication Preview PDF
Publication Date
Thu Oct 12 2017
Journal Name
Iraqi Journal Of Laser
A Comparative Evaluation of Post-Operative Pain and Function after Gingival Depigmentation Using 940 Nm Diode Laser And Conventional Bur Method: 6 Months Study
...Show More Authors

The aim of the study was to evaluate the efficacy of diode laser (λ=940 nm) in the management of gingival hyperpigmentation compared to the conventional bur method. Materials and methods: Eighteen patients with gingival hyperpigmentation were selected for the study with an age between 12-37 years old. The site of treatment was the upper gingiva using diode laser for the right half and the conventional method for the left half. All patients were re-evaluated after the following intervals: 3 days, 7 days, 1 month and 6 months post-operation. Pain and functions were re-evaluated in each visit for a period of 1 day, 3 days and 1 week post-operation. Laser parameters included 1.5 W in continuous mode with an initiated tip (400 μm) placed in

... Show More
View Publication Preview PDF
Publication Date
Fri Sep 26 2025
Journal Name
Journal Of Baghdad College Of Dentistry
An Evaluation of Corrosion Pits in Esthetic Coated Stainless Steel Orthodontic Archwires in Dry and Wet Environment at Different Intervals (An In Vitro Study)
...Show More Authors

Background: The demand for esthetic orthodontic appliances is increasing; so the esthetic orthodontic archwires were introduced. Among them, Teflon and Epoxy coated stainless steel archwires. The amount of force available from the archwire depends on the structural properties and susceptibility to corrosion. All metallic alloys are changed during immersion in artificial saliva, chlorhexidine mouthwash andtoothpaste, but their behaviors differ from one type to another. They corrode at different rates, which lead to decrease the amount of force applied to the teeth. This in vitro study was designed to evaluate the corrosion pits in stainless steel archwires coated with Teflon and with Epoxy in dry and after immersion in artificial saliva, chl

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sun Jan 16 2022
Journal Name
Applied Sciences
Evaluation of Different Internal Designs of Hydraulic Nozzles under an Accelerated Wear Test
...Show More Authors

The use of worn-out agricultural nozzles in pesticide application has a negative effect on the efficiency and cost of the application process. It also has an effect on environmental pollution due to an excessive amount of pesticide being applied when spraying with worn-out nozzles. In this paper, the resistance to wear of three different internal design hydraulic nozzles was ascertained. Changes in the flow rate and spray distribution as a result of this wear were also investigated. The wear test was done inside a closed system, and it was accelerated using an abrasive material to generate 100 h of wear. The tested nozzles were the Turbo TeeJet (TT)-twin chambered, Turbo Twinjet (TTj60)-dual outlet, and Drift Guard (DG)-pre-orifice.

... Show More
View Publication
Scopus (7)
Crossref (6)
Scopus Clarivate Crossref
Publication Date
Wed Sep 14 2016
Journal Name
Journal Of Baghdad College Of Dentistry
Comparison of Shear Bond Strength of Three Different Brackets Bonded on Zirconium Surfaces (In Vitro Study)
...Show More Authors

Background: With the increased in the demands of adult orthodontics, the challenge of direct bonding to non-enamel surface (zirconium) had been increased. The present study was carried out to compare the shear bond strength of three different brackets (stainless steel, sapphire and composite) bonded to zirconium surface and study the mode of bond failure. Materials and methods: The sample was comprised of 30 models (8mm *6mm*1.5mm) of full contour zirconium veneers. They were divided into three groups according to the brackets type; all samples were treated first by sandblast with aluminum oxide particle 50 µm then coated by z-prime plus primer. A central incisor bracket of each group was bonded to the prepared zirconium surface with lig

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Wed Jun 03 2015
Journal Name
Al-kindy College Medical Journal
Aneurysmal bone cyst of the lateral end of clavicle in a twelfth year old girl Case study
...Show More Authors

Introduction: An aneurysmal bone cyst are enigmatic lesion of unknown cause and presentation and are difficult to distinguish from other lesions, it is a benign, but expansible tumor like lesion that generally occurs in the long bones. An aneurysmal bone cyst arising from the flat bone like clavicle is rare . Case presentation: We report a 12-year-old girl child with an aneurysmal bone cyst of the lateral third of left clavicle treated with enblock resection. The pathologic findings confirmed the diagnosis of aneurysmal bone cyst. The patient has been followed up for one year with no evidence of recurrence . Conclusion: En bloc resection can be curative and provide good results for this rare type of clavicle tumour.

View Publication Preview PDF