Background: The demand for esthetic orthodontic appliances is increasing; so the esthetic orthodontic archwires were introduced. Among them, Teflon and Epoxy coated stainless steel archwires. The amount of force available from the archwire depends on the structural properties and susceptibility to corrosion. All metallic alloys are changed during immersion in artificial saliva, chlorhexidine mouthwash andtoothpaste, but their behaviors differ from one type to another. They corrode at different rates, which lead to decrease the amount of force applied to the teeth. This in vitro study was designed to evaluate the corrosion pits in stainless steel archwires coated with Teflon and with Epoxy in dry and after immersion in artificial saliva, chlorhexidine(0.2%( (Parodontax) and toothpaste media (Sensodyne) for (1, 7 and 28) days intervals. Moreover, this study is intended to compare the corrosion pits for each type of archwires at these different media among all intervals. Materials and Methods: In this study, two hundred forty pieces of orthodontic wires of Teflon (Hubit) coated Stainless steel (120 pieces) and epoxy (Orthotechnology) coated Stainless steel (120 pieces), rectangular in cross section, size (0.019 x 0.025) inch and 15mm in length divided into four groups according to immersion media: (dry environment group, artificial saliva group, chlorhexidine group and toothpaste group). The atomic force microscope was used to measure the corrosion pits for all samples at dry and wet conditions and after different immersion periods. Results: Statistical analysis showed that there was a highly significant increase in the corrosion pits of Teflon coated stainless steel archwires (P ≤ 0.05) in wet environment at 28 days immersion period.The highest corrosion pits were found in the toothpaste medium for the two archwire types at 28 days immersion period. Conclusion: We can conclude that Epoxy coatedstainless steel archwires are indicated to be used above Teflon coated stainless steel archwires in terms of corrosion resistance. IfTeflon coated stainless steel archwires should to be used, they should be change in shorter periods than Epoxy coated stainless steel archwires type Key words: Esthetic coated archwire, corrosion, Teflon, Epoxy, wet environment, AFM.
Background: The accuracy of fitness of any dental casting is imperative for the success of any prosthodontic treatment. From the time that dental casting was first introduced, efforts have been made to produce more accurate and better fitted castings with minimal marginal discrepancy. The aim of this in vitro study was to evaluate the effects of three different investing and burnout techniques on the vertical marginal discrepancies ofceramometalcopings invested with two types of phosphate- bonded investments. Materials and methods: Sixty wax patterns were fabricated on a standardized prepared brass die representing an upper central incisor by the aid of a custom-made split mold. Three different investing and burnout techniques were applied
... Show MoreItraconazole (ITZ) is an antifungal drug (BCSII) used for the treatment of local and systemic fungal infections. Furthermore, ITZ used as an antifungal prophylaxis for immunocompromised patients.
The objective of the study is to overcome the two problems of low and pH dependent solubility of ITZ by its preparation as floating microparticles.
Firstly, pH-dependent floating microparticles were prepared using oil in water solvent evaporation method, from which the best one (F7) selected as a best pH-dependent formula with composition of ITZ (200mg),EC (800mg), HPMC 15cps (200mg) and safflower oil (2ml) .Then, F7 was compared with the selected Relatively pH-independent ITZ floating microparticles formula wit
... Show MoreSelexipag is an orally selective long-acting prostacyclin receptor agonist, which indicated for the treatment of pulmonary arterial hypertension. It is practically insoluble in water ( class II, according to BCS). This work aims to prepare and optimized Selexipag nanosuspensions to achieve an enhancement in the in vitro dissolution rate. The solvent antisolvent precipitation method was used for the production of nanosuspension, and the effect of formulation parameters (stabilizer type, drug: stabilizer ratio, and use of co-stabilizer) and process parameter (stirring speed) on the particle size and polydispersity index were studied. SLPNS prepared with Soluplus® as amain stabilizer (F15) showed the smallest particle size 47nm wi
... Show MoreThe galvanic corrosion of the (Cu - Fe), (Cu - Zn) and (Fe - Zn) couples have been investigated in 3.5% NaCl solution, 40ºC, different velocities (Re = 5000, 10000 and 15000) and different area ratio’s of cathode to anode (AR= 0.5,1 and 2), by using commercial metal pipe (cylindrical tube).The Zero Resistance Ammeter has been used to measure the galvanic current (Ig) and galvanic potential (Eg) with time. The galvanic current density increases with increasing velocity (Re) and the area ratio (AR). The galvanic potential (Eg) is shifted to less negative with increasing velocity (Re) and the area ratio (AR). A statistical relations for the galvanic current density and galvanic potential as a function of (Re). and the area ratio had been
... Show MoreIn the 20th century, the concept of "sarcasm" has relatively prevailed, and in this sense, it is a method in the art of conversation that wants to keep the question about the intended meaning, that is, "saying something and suggesting its opposite."
There are other concepts that indicate that sarcasm is saying something in a way that provokes the recipient of the statement an infinite number of different interpretations, with multiple readers of different interpretations. While the philosophy of irony stands by the standards of things, exaggeration or minimization, this manipulation takes place within the enjoyment. However, it's a method to present sharp criticism in an atmosphere of criticism that differs from generation to gener
The purpose of this study was to evaluate the epidemiological characteristics of the mandibular fractures relating to gender, age, the etiology of injury, and the rendered treatment modalities and complications. The data of the patients who sustained mandibular fractures were retrieved and were analyzed retrospectively, and based on these data a descriptive analysis was conducted. A total of 112 patients were included in this study; the most common cause was road traffic accidents (RTAs) followed by assaults and missile injuries. The most frequently involved age group was 11 to 20 years, treatment modalities included conservative, closed reduction and indirect fixation, and open reduction and internal fixation (ORIF) in 11.6, 79.5, and 8.9%
... Show MoreBackground: The study was designed to evaluate the effect of local application of exogenous VEGF/collagen I separately and as a combination in socket healing. Sixty male Albino Wistar rats were subjected for a surgical tooth extraction of upper 1st molar of both sides (right side was considered as experimental site, while left be the control one, treated with 1µL of normal saline). The rats were scarified at 3, 7, 14, 28 days post extraction. Socket healing was histologically examined with immunohistochemistochemical localization of ALP&FGF2. Materials and Method: Sixty male Albino Wistar rats were subjected for a surgical tooth extraction of upper 1stmolar of both sides (right side was considered as experimental site, while left be the
... Show MoreBackground: Endodontically treated teeth have low resistance to fracture against occlusal forces. The strengthening effect of bonded esthetic onlay restoration on weakened tooth has been reported. This study aimed to assess the fracture resistance of endodontically treated premolars restored with composite with and without cuspal coverage by using direct and indirect techniques. Indirect technique done by CAD/CAM system (computer aided design –computer aided manufacturer) and laboratory processing. Material and methods: Forty human extracted maxillary premolars of approximately comparable sizes were divided into four groups: Group (A): Ten endodontically treated teeth directly filled with Filtek Z250xt without cuspal coverage. Group
... Show MoreIn this work, synthesized N4,N4`-bis(2, 3, 4 nitro benzylidene) biphenyi-4-4`-diamine(B1-B3) , was tested as an inhibitors in controlling the corrosion of carbon steel in NaCl 3.5% solution by using open circuit potential (OCP),at four different temperatures (293, 303, 313 and 323 K). Furthermore, the surface morphology was investigated using the Atomic force microscopy (AFM). The effect of using different Schiff bases and temperature was also investigated. Schiff bases was synthesized and characterized via using. Fourier Transform Infrared Spectroscopy (FT-IR)and Atomic Force Microscope (AFM) characterized . The experimental results shown that Schiff bases can consider as an excellent corrosion inhibitors for carbon steel in NaCl 3
... Show More