Background: Bimaxillary protrusion is considered as one of the most important causes to seek the orthodontic treatment to get better esthetics. This study aimed to test the effect of orthodontic treatment in improvement the facial esthetics. Materials and Methods: Ten Iraqi Arab females having bimaxillary protrusion based on Class I malocclusions treated with fixed orthodontic appliance and extraction of the maxillary and mandibular 1st permanent premolars. Pre and post-treatment facial profile photographs were taken for each patients and the effect of treatment was tested in comparison with the pre-treatment photographs by using seven angular measurements. Results: After treatment, the upper and lower lip projections were decreased significantly, the naso-labial and mento-labial angles were increased significantly. Conclusion: Treatment of bimaxillary protrusion with fixed orthodontic appliances and extraction of four premolars improve the facial esthetics of the patients by decreasing the lip projection and increasing the naso-labial and mento-labial angles. Key words: Bimaxillary protrusion, facial esthetics, photographs.
Acontaminated ophthalmic solutions represent a potential cause of avoidable ocular infection. This study aimed to determine the magnitude and pattern of microbial contamination of eye drops in out patient at the department of ophthalmology, at Baghdad national hospital, Iraq. Fifty four vials from the out patient clinic were obtained for microbial examination after an average use of 2 weeks. The dropper tip and the residual eye drop were examined for contamination. The specimens were cultured, the number of colonies counted, the organisms identified. Eight (15%) out of 54 analyzed vials were contaminated , most bacteria identi
... Show MoreElbow stiffness is hard to treat and commonly resulted from trauma or degenerative arthritis. This study aimed to demonstrate the effectiveness of using ultrasound therapy in management of stiff elbow joint resulted from several etiological factors. A total number of 42 patients (35 male and 7 female) allocated randomly from the Department of Physiotherapy at Al-yarmouk Teaching Hospital during 2013. Each patient examined physically by physiotherapist taking in consideration the measurement of the joint movement angle using goniometer in flexion and the extension, and the pain score using visual analogue scale (VAS). Ultrasound therapy initiated thrice weekly for two weeks. At the time of entry, the means degree of flexion and extension
... Show More
The present investigation deals with experimental study of three-phase direct-contact heat exchanger, for water-Freon R11 system, where water is the continuous phase (liquid) and Freon R11 (liquid-gas) is the dispersed phase. The test section consisted of a cylindrical Perspex column with inner diameter 8cm and 1.2m long, in which, water was to be confined. Liquid Freon R11 drops were injected into the hot water filled column, through a special design of distributors at the bottom of the column. The liquid Freon R11 drops rose on their way up and evaporated into two-phase bubbles at atmospheric pressure. The study was devoted to express the effect of process variables such as c
... Show MoreSulphated zirconia (SZ) is one of the most important solid acid catalysts was synthesize at different operating conditions, different calcination temperature and sulfonating time has been used. The prepared catalyst was distinguished by X-ray Diffraction (XRD), particle size and morphology of catalyst were checked by atomic force microscopy (AFM) and scanning electron microscopy (SEM) respectively, in addition to analysis by (DTA) Differential thermally and Energy Dispersive X-Ray (EDX). Finally, the N2 adsorption-desorption was used to measure the surface area (BET) and pore volume. High degree of tetragonal crystallinity was obtained 90 %, and surface area of 169 m2/g and pore volume of 0.39 cm3g-1 at 600°C calcination temperature for 3
... Show MoreThe use of essential services in modern constructions, such pipes, and ducts, became important, placing these pipes and ducts underneath the soffit of the beam. They made a ceiling sandwich, and that causes to reduce the height of the floor, so the presence of the opening in the beam saves the height of the floor. In this paper, the investigation of the beam response of reinforced concrete simply supported rectangle beams with square web openings is presented, including a number of the web openings (two, four, and eight), in addition to its use in strengthening the member at the openings (when the beam is planned before casting, internal deformation steel bar is used, and in case of the opening is existing in the b
... Show MoreThis paper proposes a compact, plasmonic-based 4 × 4 nonblocking switch for optical networks. This device uses six 2 × 2 plasmonic Mach-Zehnder switch (MZS), whose arm waveguide is supported by a JRD1 polymer layer as a high electro-optic coefficient material. The 4 × 4 switch is designed in COMSOL environment for 1550 nm wavelength operation. The performance of the proposed switch outperforms those of conventional (nonplasmonic) counterparts. The designed switch yields a compact structure ( 500 × 70 µ m 2 ) having V π L = 12 V · µ m , 1.5 THz optical bandwidth, 7.7 dB insertion loss, and −26.5 dB crosstalk. The capability of the switch to route 8 × 40 Gbps WDM signal is demonstrated successfully.
... Show MoreThe solar photocatalytic degradation of diuron, which is one of the herbicides, has been studied by a solar pilot plant in heterogeneous solar photocatalysis with titanium dioxide. The pilot plant was made up of compound parabolic collectors specially designed for solar photocatalytic applications. The influence of different variables such as, H2O2 initial concentration, TiO2 initial concentration, and diuron initial concentration with their relationship to the degradation efficiency were studied. Hydrogen peroxide (H2O2) found to increase the rate of diuron degradation. The best removal efficiency of heterogeneous solar photocatalytic TiO2 system was found to be 46.65 % and for heterogeneous solar photocatalytic TiO2/ H2O2 system was fo
... Show MoreBackground: Endometrial Cancer (EC) is the malignant tumor originating from endometrium cell (lining of the uterus). EC incidence and mortality have increased in recent years. Routinely used methods for EC diagnosis and treatment are histopathological tissue culture after surgery and postoperative radiotherapy, however there is still not enough efficient treatment for recurrence or progression of this disease. So, there is a critical need for further EC identification by new biological ways for the prognostic diagnosis of it. Objective: This study aimed to look for ways by which could help in diagnosis of EC before the hysterectomy. Materials and Methods: 55 patients with EC and 57 healthy women were involved in this study (up to 45 years)
... Show MoreOver the past few decades, the surveying fieldworks were usually carried out based on classical positioning methods for establishing horizontal and vertical geodetic networks. However, these conventional positioning techniques have many drawbacks such as time-consuming, too costly, and require massive effort. Thus, the Global Navigation Satellite System (GNSS) has been invented to fulfill the quickness, increase the accuracy, and overcome all the difficulties inherent in almost every surveying fieldwork. This research assesses the accuracy of local geodetic networks using different Global Navigation Satellite System (GNSS) techniques, such as Static, Precise Point Positioning, Post Processing Kinematic, Session method, a
... Show MorePhotonic Crystal Fiber Interferometers (PCFIs) are greatly used
for sensing applications. This work presents the fabrication and
characterization of a relative humidity sensor based on Mach-
Zehnder Interferometer (MZI), which operates in reflection mode.
The humidity sensor operation based on the adsorption and
desorption of water vapour at the silica-air interface within the PCF.
The fabrication of this sensor is simple, it only includes splicing and
cleaving the PCF with SMF.PCF (LMA-10) with a certain length
spliced to SMF (Corning-28).
The spectrum of PCFI exhibits good sensitivity to humidity
variations. The PCFI response is observed for a range of humidity
values from (27% RH to 85% RH), the positi