Background: Masseter muscle is one of the most obvious muscles of mastication and considered as one indicator of jaw muscle activity. It has a major influence on the transverse growth of the midface and the vertical growth of the mandible. This study undertaken to determine the role of cephalometric analysis for discrimination between Cl I and Cl III skeletal relationships, determine the role of ultrasonography in determination of masseter muscle thickness, compare masseter muscle thickness between Cl I and Cl III skeletal relationships, and determine the effect of gender on masseter muscle thickness. Material and Method: The sample of the current study consisted of 70 Iraqi subjects 40 males and 30 females with age ranging 18-25 years. They were divided into 2 groups depending on ANB angle: class I skeletal relationship 20 males and 15 females and class III skeletal relationship 20 males and 15 females. The collected sample included patients attended for different diagnostic purposes to the Dental Radiology Department at College of Dentistry/Babylon University, standardized lateral cephalogram was taken to determine facial morphology, six angular and eight linear measurements were assessed. Masseter muscle thickness measured ultrasonography in Al-Hilla General Teaching Hospital/Ultrasonorgaphic Department, in relaxation and contraction conditions for both sides. Results: Various parameters measured for males and females in each class and the comparison shown statistically significant differences between them (P<0.05). No difference in muscle thickness between right and left sides in the same class (P>0.05). Gender variation showed significant difference in masseter muscle thickness during rest and occlusion conditions (P<0.001). Conclusion: Cephalometric analysis served to demonstrate the skeletal morphologies and provide a base for discrimination between class I and class III skeletal relationships. Ultrasonographic scanning is an important imaging procedure. It is reproducible and simple method for accurately measuring masseter muscle thickness. The ultrasonorgaphic study has revealed variations in masseter muscle thickness among individuals with different skeletal morphologies in each gender on one hand and between males and females in each skeletal class on the other hand. Key words: Masseter muscle thickness, skeletal morphology, cephalometric analysis, ultrasonorgaphic scanning.
People with diabetes can develop different foot problems. In the blood stream glucose reacts with hemoglobin to make a glycosylated hemoglobin molecule called hemoglobin A1c or HbA1c, the more glucose in the blood the more hemoglobin A1c will be present in the blood. The HbAlc test is currently one of the best ways to check diabetes to be under control. The aim of study is to compare between the blood investigations which includes the fasting blood sugar and HbAlC (glycosylated hemoglobin), and to evaluate the benefit of HbAlc (measurement for diabetic patients with foot ulcer, to be a good indicator for controlling blood glucose). Sixty patients with type2 diabetes mellitus from the outpatient clinic of Baghdad Teachin
... Show MoreBenign prostatic hyperplasia (BPH) is a prevalent condition among elderly and middle-aged men characterized by symptoms such as dysuria, urinary incontinence, and frequent micturition. The gold standard procedure for relieving BPH symptoms is transurethral resection of the prostate (TURP). However, some patients undergoing TURP are at risk of developing urinary tract infections (UTIs) due to uropathogenic bacteria. This prospective study aimed to investigate post TURP bacteruria alongside with multifactoria risk factors that implicated postoperatively compared to preoperative and intraoperative periods. Ninety patients undergoing TURP and 30 control subjects were included in the study. Urine specimen for urine analysis from pateints
... Show MoreThe qualified subjects for this study included 33 patients with benign and malignant oral tumors aged 15-75 years and 31 matched age and gender healthy subjects used as control. Proteins measurements included total protein, albumin, globulines in sera and saliva samples, and immunoglobulins (IgG, IgM, IgA) in sera samples of control and patients. Meanwhile, polyacrylamide gel electrophoresis (PAGE) was used to differentiate between protein patterns in both serum and saliva samples among the studied groups. The gel was also stained for glycoprotein to evaluate as well the changes in glycoprotein contents. For total protein, the results revealed a signifigant increase (P?0.01) in both samples (serum and saliva) of patient group. Albumin conce
... Show MoreA transdermal drug delivery system (TDDS) is characterized by the application of medications onto the skin's surface to deliver drugs at a controlled and predefined rate through the skin. Spanlastics, an elastic nanovesicle capable of transporting various pharmacological substances, shows promise as a drug delivery carrier. It offers numerous advantages over traditional vesicular systems applied topically, including enhanced stability, flexibility in penetration, and improved targeting capabilities. This study aims to develop meloxicam (MX)-loaded spanlastics gel as skin delivery carriers and to look into the effects of formulation factors like Tween80, Brij 35, and carbopol concentration on the properties of spanlastics gel, like pH, drug
... Show MoreIn this study, generation of elliptical gears with different teeth profiles of crowned involute, double circular arc (DCA), and combined (crowned involute with DCA) has been developed. The resulting mathematical equations have been computerized and feed to CNC end mill machine to manufacture elliptical gear models with different profiles. These models are investigated in plane polariscope to show the resulting stresses under certain load. Comparison of photo-elastic stress results shows that combined elliptical gears with DCA side as a loaded side have a minimum resulting contact stress with a reduction percentage of 40% compare with contact stresses in counterpart elliptical gear of involute profile (which is commonly u
... Show MoreAbstract
The fiber Bragg grating (FBG) technology has been rapidly applied in the sensing technology field. In this work, uniform FBG was used as pressure sensor based on measuring related Bragg wavelength shift. The pressure was applied directly by air compressor to the sensor and the pressure was ranged from 1 to 6 bar.
This sensor also was affected by the external temperature so as a result it could be used as a temperature sensor. This sensor could be used to monitor the pressure of dams. It has been shown from the result that the sensor is very sensitive to the pressure and the sensitivity was (67 pm\bar) and is very sensitive to temperature and the sensitivity was (10p
... Show MoreCefixime (CFX) was treated with sodium nitrite and hydrochloric acid for diazotization reaction followed by coupling with ?-Naphthol in alkaline medium to form, a yellow colored azo dye compound which exhibits maximum absorption (?max) at 412 nm where the concentration of (CFX) was determined spectrophotometrically. The optimum reaction conditions and other analytical parameters were evaluated. Beer’s law was obeyed in the concentration range of (1-20) ?g.mL-1 with a molar absorptivity of 34870.5 L.mol-1.cm-1. The limit of detection was found to be 0.1090 ?g.mL-1 and the Sandell's sensitivity value was 0.0130 ?g.cm-2. The proposed method could be successfully applied to
... Show MoreCams are considered as one of the most important mechanical components that depends the contact action to do its job and suffer a lot of with drawbacks to be predicted and overcame in the design process. this work aims to investigate the induced cam contact and the maximum shear stress energy or (von misses) stresses during the course of action analytically using Hertz contact stress equation and the principal stress formulations to find the maximum stress value and its position beneath the contacting surfaces. The experimental investigation adopted two dimensions photoelastic technique to analyze cam stresses under a plane polarized light. The problem has been numerically simulated using Ansys software version 15 as FE
... Show More