Background: Errors of horizontal condylar inclinations and Bennett angles had largely affected the articulation of teeth and the pathways of cusps. The aim of this study was to estimate and compare between the horizontal condylar (protrusive) angles and Bennett angles of full mouth rehabilitation patients using two different articulator systems. Materials and Methods: Protrusive angles and Bennett angles of 50 adult males and females Iraqi TMD-free full mouth rehabilitation patients were estimated by using two different articulator systems. Arbitrary hinge axis location followed by protrusive angles and Bennett angles, estimation was done by a semiadjustable articulator system. A fully adjustable articulator system was utilized to locate the terminal hinge axis using a kinematic face bow followed by protrusive angles location by the aid of two square shaped transparent hard plastic protractors attached close to the condylar stylus of the articulator followed by Bennett angles calculation according to the Hanau formula. All results were subjected to statistical analyses. Results: The two articulator systems scored protrusive angles for male patients greater than female patients which were non-significant for the fully adjustable articulator but they were significant for the semiadjustable articulator. Non-significance existed between females of the fully adjustable articulator and males of the semiadjustable articulator while high significance was located between males of the fully adjustable articulator and females of the semiadjustable articulator. Concerning Bennett angles, the highest mean value belonged to the male group of the fully adjustable articulator, while the lowest scored by the female group of the semiadjustable articulator. Highly significant differences were located between the Bennett angle mean values of the groups. Conclusion: Using both articulators, the total mean values of the males were greater than the females regarding both horizontal condylar angles and Bennett angles with the total means scored by the fully adjustable articulator being larger than those of the semi-adjustable type. Using both articulators, the males' right and left condyles exhibited greater Bennett angles than their female equivalents. The precision estimation of the horizontal condylar angles and Bennett angles provided by the condylar axis protractors of the fully adjustable articulator render such type of articulators most suitable for treating full mouth rehabilitation cases. Keywords: Horizontal codylar angles, Bennett angles, two articulator systems.
Background: osteoporosis is characterized by a reduction in bone mineral density, skeletal microstructure breakdown, increased bone fragility, and fracture susceptibility. Osteopenia is the preceding step to osteoporosis because it causes a decrease in bone mass, osteoporosis reduces a person's quality of life. Periostin (encoded by Postn), its name is derived from the fact that it was first detected in periosteal osteocytes and osteoblasts. Periostin deficiency has been linked to osteoporosis and weak bones. Study objectives: The purpose of this study was to determine periostin levels in serum of Iraqi patients with osteoporosis and osteopenia, and it is also possible to consider periostin as a diagnostic factor to follow the progression o
... Show MoreFor aspirin estimated, a molecularly imprinted polymer MIP-ASP electrodes were generated by electro-polymerization process, the electrodes were prepared by combining the template (aspirin) with (vinyl acetate (VA), 1-vinylimidizole (VIZ) as a functional monomer and N, N-methylene bisacrylamide (MBAA) as crosslinkers using benzoyl peroxide (BPO) as an initiator. The efficiency of the membrane electrodes was analyzed by differential pulse voltammetry (DPV). Four electrodes were synthesized using two different plasticizers, di-butyl sebacate (DBS), di-octyl phthalate (DOP) in PVC matrix. Scanning electron microscopy (SEM) was used to describe the generated MIP, studying the electrodes properties, the slope, detection limit, and life
... Show MoreObjective: Geographic differences in clinical and pathological aspects of ameloblastoma have been suggested, therefore the purpose of this study was to analyze cases of ameloblastoma in terms of clinical and radiographic manifestations, histopathological types, treatment modalities and recurrence rate and compare them with reports from other parts of the world. Methods: The medical reports of patients diagnosed with ameloblastoma were reviewed and the data concerning the age, gender, chief complaint, the anatomical site of the lesion, radiographic appearance, histopathological diagnosis, treatment approach and recurrence were retrieved. Surgical treatment consisted of either enucleation with curettage and peripheral ostectomy or resection;
... Show MoreBackground:Â Various fluids in the oral environment can affect the surface roughness of resin composites. This in vitro study was conducted to determine the influence of the mouth rinses on surface roughness of two methacrylate-based resin (nanofilled and packable composite) and siloraine-based resin composites.
Materials and methods: Disc-shaped specimens (12 mm in diameter and 2mm in height) were prepared from three types of composi
... Show MoreThree cohesionless free flowing materials of different density were mixed in an air fluidized bed to study the mixing process by calculating performance of mixing index according to Rose equation (1959) and to study the effect of four variables (air velocity, mixing time, particle size of trace component and concentration of trace component) on the mixing index and as well as on mixing performance. It was found that mixing index increases with increasing the air velocity, mixing time and concentration of trace component until the optimum value. Mixing index depends on the magnitude of difference in particle size The first set of experiments (salt then sand then cast iron) give higher mixing index and better performance of mixing than the
... Show MoreBackground: The bonded orthodontic retainer constructed from multistrand wire and composite is an efficient esthetic retainer, which can be maintained long-term. Clinical failures of bonded orthodontic retainers, most commonly at the wire/composite interface, have been reported. This in vitro investigation aimed to evaluate the tensile forces of selected multistrand wires and composite materials that are available for use in the construction of bonded fixed retainers. Materials and Methods: The study sample includes 120 wires with three types of retainer wires (3 braided strands\ Orthotechnology, 8 braided strands\ G&H Orthodontics, 6 coaxial strands\ Orthoclassic wires), two types of adhesive (flowable\ Orthotechnology, non flowable\ G&H O
... Show MoreTo determine the relationship between chronic hepatitis B virus and autoimmune celiac disease, seventy five patients with chronic hepatitis B virus of ages (8-70) years have been investigated and compared with 50 healthy individuals. All the studied groups were carried out to measure antiGliadin antibodies IgA and IgG by ELISA test and anti-reticulin antibodies IgA and IgG by IFAT. There were significant elevation (P<0.05) in the concentration of AGA IgA and IgG antibodies compared to control group. The prevalence of AGA antibodies IgA and IgG was 8% and 9.33% respectively. There were a highly significant differences (P<0.01) between studies groups. The prevalence of antireticulin antibodies ARA IgA and IgG was 6.67% and 4.0% respectively i
... Show MoreMost studies on deep beams have been made with reinforced concrete deep beams, only a few studies investigate the response of prestressed deep beams, while, to the best of our knowledge, there is not a study that investigates the response of full scale (T-section) prestressed deep beams with large web openings. An experimental and numerical study was conducted in order to investigate the shear strength of ordinary reinforced and partially prestressed full scale (T-section) deep beams that contain large web openings in order to investigate the prestressing existence effects on the deep beam responses and to better understand the effects of prestressing locations and opening depth to beam depth ratio on the deep beam performance and b
... Show MoreThe main goal of this in vivo study was to evaluate the effect of 532nm Q-switched Nd: YAG Laser in combination with Human Serum Albumin 20% concentration (as a welding aid) on the liver tissue repair clinically, and histologically. The animals used in this study were 21 male rabbits divided into three main groups: control group (3 rabbits), conventionally treated group (9 rabbits) and Laser treated group (9 rabbits). Each two main groups (conventional and laser treated) consist of three sub-groups depending on the response evaluation at three different periods. The Laser group was treated using 532nm Q-switched Nd: YAG laser after adding human serum albumin immediately on the incised liver’s tissue. The energy of was 460mJ, and 4Hz fr
... Show More