Preferred Language
Articles
/
jUJVAJoBMeyNPGM39rth
A simple stability-indicating HPLC method for simultaneous analysis of paracetamol and caffeine and its application to determinations in fixed-dose combination tablet dosage form
...Show More Authors

A simple, economic, rapid, reliable, and stability-indicating high-performance liquid chromatography (HPLC) method has been developed and validated for the simultaneous determination of paracetamol (PCM) and caffeine (CF) in solid dosage form. The chromatographic separations were achieved with a Waters Symmetry® C18 column (5 μm, 4.6 × 150 mm), using a mixture of methanol and water (40:60, v/v) as a mobile phase, under isocratic elution mode with a flow rate of 0.8 mL/min, and ultraviolet (UV) detection was set at 264 nm. The oven temperature for the column was set and maintained at 35 °C. The method was validated according to International Conference on Harmonization (ICH) guidelines, and it demonstrated excellent linearity, with a correlation coefficient of 1 and 0.9999 for PCM and CF, respectively, over the concentration ranges of 15–300 μg/mL (PCM) and 2.5–50 μg/mL (CF). The retention time (tR) was found to be 2.6 ± 0.001 and 3.5 ± 0.002 min for PCM and CF, respectively. Extensive stress degradation studies were conducted by subjecting the analytes to various stress conditions of acidic and alkaline hydrolysis as well as oxidative, photolytic, and heat degradations. The method was found to efficiently separate the analytes' peaks from that of the degradation products, without any variation in their retention times. The relative standard deviation (RSD) values of all recoveries for PCM and CF were less than 1.3%. The method was found to be suitable for routine analysis of PCM and CF in pharmaceutical dosage form.

Scopus Clarivate Crossref
View Publication
Publication Date
Sun Jun 02 2013
Journal Name
Baghdad Science Journal
Extraction and Determination of Amygdaline in Iraqi Plant Seeds Using the Combined Simple Extraction Procedure and High-Performance Liquid Chromatography
...Show More Authors

Abstract :In this study, amygdaline in Iraqi plant seeds was extracted and isolated from their seeds matrix using reflux procedure and subsequently identified and determined by high performance liquid chromatography (HPLC) on reversed phase column of LC-18 (150mm x 4.6mm, 5?m )with actonitrile :water ( 50 : 50 ) as mobile phase at flow rate of ( 0.5 mL/min ) and detection at wavelength of 215 nm.The experimental results indicated that the linearity of calibration is in the range of 1.0-30.0 mg L-1amygdaline with the correlation coefficient of 0.9949. The limit of detection (LOD) and limit of quantitation (LOQ) for amygdaline were of 0.88 and 2.93 mg L-1 in standard pure sample. The mean recovery percent is 97.34±0.58 at 95% confidence inte

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Mon Jun 01 2020
Journal Name
Journal Of Engineering
Reliability Analysis of Multibit Error Correcting Coding and Comparison to Hamming Product Code for On-Chip Interconnect
...Show More Authors

Error control schemes became a necessity in network-on-chip (NoC) to improve reliability as the on-chip interconnect errors increase with the continuous shrinking of geometry. Accordingly, many researchers are trying to present multi-bit error correction coding schemes that perform a high error correction capability with the simplest design possible to minimize area and power consumption. A recent work, Multi-bit Error Correcting Coding with Reduced Link Bandwidth (MECCRLB), showed a huge reduction in area and power consumption compared to a well-known scheme, namely, Hamming product code (HPC) with Type-II HARQ. Moreover, the authors showed that the proposed scheme can correct 11 random errors which is considered a high

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Sep 04 2016
Journal Name
Baghdad Science Journal
A Study the Effect of TiO2 Nanoparticles Combination with Antibiotics and Plant extracts Against Some Gram Negative Bacteria
...Show More Authors

Titanium dioxide TiO2 has been widely utilized in cleaning and sterilizing material for many clinical tools sanitary ware, food tableware and cooking and items for use in hospitals. Titanium dioxide TiO2 non toxicity and long term physical and chemical stability. It has been widely used decomposition of organic compounds and microbial organisms such as cancer cell, viruses and bacteria as well as its potential application in sterilization of medical devices. The aim of the study the effect of titanium dioxide TiO2 on some Gram negative bacteria and study their effects on some virulence factors and chromosomal DNA.In this study, we obtained (E. coli ? Proteus mirabilis, Proteus vulgaris ? Pseudomonas aeruginosa ? Klebsiella pneumonia and Ac

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Thu Feb 03 2022
Journal Name
Biologia
Developing multiplex PCR for the rapid and simultaneous detection of Staphylococcus aureus, Pseudomonas aeruginosa and Klebsiella pneumoniae associated with sheep respiratory tract infections
...Show More Authors

Respiratory tract infections in sheep are among the important health problems that affect all sheep ages around the world. Nine bacterial isolates obtained from sheep with respiratory tract infections were selected to be used in the current study. The isolates included 3 Staphylococcus aureus, 4 Klebsiella pneumoniae, and 2 Pseudomonas aeruginosa. Following the primers design by the Primer3Plus software tool and optimization of the conventional polymerase chain reaction (PCR), the primers were validated for their use in the multiplex PCR experiments. The MFEprimer program was used to check the suitability of the primer set combinations for multiplex PCR. The MFEprimer software was successful in designing the multiplex-PCR experiments and de

... Show More
View Publication
Scopus (3)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Mon Jun 01 2009
Journal Name
Journal Of Economics And Administrative Sciences
Estimation of the average sample size and defective ratio In a finite individualized inspection with a practical application
...Show More Authors

The purpose of this research is to find the estimator of the average proportion of defectives based on attribute samples. That have been curtailed either with rejection of a lot finding the kth defective or with acceptance on finding the kth non defective.

The MLE (Maximum likelihood estimator) is derived. And also the ASN in Single Curtailed Sampling has been derived and we obtain a simplified Formula All the Notations needed are explained.

View Publication Preview PDF
Crossref
Publication Date
Fri Jan 01 2016
Journal Name
Asian J Pharm Clin Re
EFFECT OF NATURAL AND SYNTHETIC POLYMERS ON THE PROPERTIES OF CANDESARTAN CILEXETIL MATRIX TABLET PREPARED BY DRY GRANULATION
...Show More Authors

Publication Date
Thu Dec 01 2016
Journal Name
Asian Journal Of Pharmaceutical And Clinical Research
EFFECT OF NATURAL AND SYNTHETIC POLYMERS ON THE PROPERTIES OF CANDESARTAN CILEXETIL MATRIX TABLET PREPARED BY DRY GRANULATION
...Show More Authors

ABSTRACTObjective: The objective of this study is to develop a controlled release matrix tablet of candesartan cilexetil to reduce the frequency of administration,enhance bioavailability and improve patient compliance; a once daily sustained release formulation of candesartan cilexetil is desirable.Methods: The prepared tablets from F1 to F24 were evaluated with different evaluation parameters like weight variation, drug content, friability,hardness, thickness and swelling ability. In vitro release for all formulas were studied depends on the type and amount of each polymer, i.e. (16 mg,32 mg and 48 mg) respectively beside to the combination effect of polymers on the release of the drug from the tablet.Results: In vitro release show

... Show More
View Publication
Scopus (10)
Crossref (1)
Scopus Crossref
Publication Date
Fri Dec 07 2018
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Novel Combination for Self-Nanoemulsifying Drug Delivery System of Candesartan Cilexetil
...Show More Authors

Solubility problem of many of effective pharmaceutical molecules are still one of the major obstacle in theformulation of such molecules. Candesartan cilexetil (CC) is angiotensin II receptor antagonist with very low water solubility and this result in low and variable bioavailability. Self- emulsifying drug delivery system (SEDDS) showed promising result in overcoming solubility problem of many drug molecules. CC was prepared as SEDDS by using novel combination of two surfactants (tween 80 and cremophore EL) and tetraglycol as cosurfactant, in addition to the use of triacetin as oil. Different tests were performed in order to confirm the stability of the final product which includes thermodynamic study, determination of self-emulsificat

... Show More
View Publication Preview PDF
Scopus (7)
Crossref (1)
Scopus Crossref
Publication Date
Fri Apr 25 2014
Journal Name
Journal Of Pharmaceutical & Scientific Innovation
EFFECT OF CARROT AND GINGER EXTRACTS (ALONE AND IN COMBINATION WITH CIPROFLOXACIN) ON MULTIDRUG RESISTANT PSEUDOMONAS AERUGINOSA
...Show More Authors

View Publication
Crossref (5)
Crossref
Publication Date
Tue Mar 03 2020
Journal Name
Aip Conference Proceedings
Correlation study of (IL-17, IL-17RA) and some biochemical parameters with patients of Iraq colorectal cancer after and before taking a dose of chemotherapy
...Show More Authors

Colorectal cancer CRC is the third most commonly diagnosed cancer in males and the second in female, so it is a common and life-threatening disease serum of 48 males and 40 females suffering from CRC disease as group one (G1) without taking a chemotherapy dose, the same patients group tow (G2) after taking the first chemotherapy dose, while group three (G3) whose patients in (G1) and (G2) after second taking a chemotherapy dose. and group four (G4) consist of (30 males and 30 females) healthy Iraqi control. Results showed a significant increase in IL-17, IL-17RA and CEA in G1, while there was a significant decrease in vitamin D concentration in G1 than other groups, also there was positive (+ ve) significant correlation between IL-17 and CE

... Show More