A simple, economic, rapid, reliable, and stability-indicating high-performance liquid chromatography (HPLC) method has been developed and validated for the simultaneous determination of paracetamol (PCM) and caffeine (CF) in solid dosage form. The chromatographic separations were achieved with a Waters Symmetry® C18 column (5 μm, 4.6 × 150 mm), using a mixture of methanol and water (40:60, v/v) as a mobile phase, under isocratic elution mode with a flow rate of 0.8 mL/min, and ultraviolet (UV) detection was set at 264 nm. The oven temperature for the column was set and maintained at 35 °C. The method was validated according to International Conference on Harmonization (ICH) guidelines, and it demonstrated excellent linearity, with a correlation coefficient of 1 and 0.9999 for PCM and CF, respectively, over the concentration ranges of 15–300 μg/mL (PCM) and 2.5–50 μg/mL (CF). The retention time (
Alginate is one of the natural biopolymers that is widely used for drug formulations, combination of alginate with other polymers, such as gum acacia, pectin, and carrageenan can increase mechanical strength, therefore, can reduce leakage of the encapsulated active pharmaceutical ingredient from the polymer matrix. Interaction of alginate and these polymers can occur via intermolecular hydrogen bonds causing synergism, which is determined from the viscosity of polymer mixture.
Alginate was combined with gum acacia/pectin/carrageenan in different blending ratios (100:0, 75:25, 50:50, 25:75, and 0:100) with and without addition of CaCl2. The synergism effect is obtained from the design of experimental (DoE), and calculati
... Show MoreIn this study, the radon gas concentration as well as the annual effective dose in leaves of the Malvasylvestris (Khabbaz) plant used in the traditional treatment and as food in Iraq, for this, it is necessary to evaluate the concentrations radon gas, which were measured using solid state nuclear track detectors (SSNTDs) CR-39 technique. The concentration and annual effective dose in samples were collected from Baghdad city ranged from minimum to maximum value 15.815 , 0.498 , 54.445 , 1.717 respectively, while the values of concentration and annual effective dose in a sample collected from Karbala are 15.297 ,0.482 . These values of concentration and annual effective dose less were compared with th
... Show MoreAbstract:
The problem of poverty is one of the most important development challenges facing developing countries including Sudan for several decades. Although many efforts have been made to reduce poverty, however, its rates are increasing, and public policies adopted by the government in this regard remain elusive in achievinging its main objectives or making any significant progress. The purpose of the present study is to analyse poverty in Sudan by identifying its measurement, causes and the factors that have contributed to the increasing poverty rates over the past two decades. Also this study aims at investigating the interim poverty reduction strategy in Sudan as well as evaluates that strategy throug
... Show MoreThe treatment of migraine headache targets the neurovascular mechanism and involves the use of serotonin receptor antagonists. Some of these drugs are used for the treatment of acute attacks; while others are effective as prophylactic measures to decrease the duration and frequency of attacks. Pizotifen, a 5-HTA antagonist, is one of the prophylactic drugs for which the clinical use resulted in low outcomes in reducing migraine symptoms. Melatonin, a serotonin derived neurohormone, was reported to exert many functions like sleep induction, anti-inflammatory, neurovascular regulation, cytoprotection and modulation of neurotransmitter release. In the view of the involvement of serotonin in the pathophysiology of migraine a
... Show MoreMetoclopramide (MCP) ion selective electrodes based on metoclopramide-phosphotungstic acid (MCP-PT) ion pair complex in PVC matrix membrane were constructed. The plasticizers used were tri-butyl phosphate (TBP), di-octyl phenyl phosphonate (DOPP), di-butyl phthalate (DBPH), di-octyl phthalate (DOP), di-butyl phosphate (DBP), bis 2-ethyl hexyl phosphate (BEHP). The sensors based on TBP, DOPP, DBPH and DOP display a fast, stable and linear response with slopes 59.9, 57.7, 57.4, 55.3 mV/decade respectively at pH ranged 2-6. The linear concentration range between 1.0×10-5 – 1.0×10-2 M with detection limit 3.0×10-6 and 4.0×10-6 M for electrodes using TBP, DOPP and DBPH while e
... Show More