Objective: The aim of the present study is to assess the practices of nurses towards standard precautions at Azady
Teaching Hospital in the City of Kirkuk.
Methodology: A descriptive study, which uses the assessment approach and it was conducted on nurses from January
18th, 2009 to September 30th, 2009, using non-probability sampling a purposive sample of (37) subject (male and
female nurses) who worked at surgical wards in Azady Teaching Hospital in Kirkuk city was selected. Two study
instruments were utilized for proper data collection [questionnaire and observational checklist]; a questionnaire was
developed for the purpose of the study. It was comprised of two parts which included the nurses' demographic
characteristics and Information related to the setting of the sample (surgical wards). A pilot study was carried out for
the period of January 18th, 2009, to February 2nd, 2009 to determine the observaƟonal checklist reliability through
the use of (Inter–rater). A panel of (19) experts was involved in the determinaƟon of the observaƟonal checklist
content validity. Data were analyzed through the application of descriptive statistical data analysis approach
(frequency, percentage, mean of scores and standard deviation), and inferential data analysis approach (chi-square).
Results: The study findings revealed that the majority (91.9%) of the nurses did not get training sessions regarding
infecƟon control and (83.4%) of them had not parƟcipated conƟnuous learning about infecƟon control. According to
the level of practices towards standard precautions, it has revealed that poor practices of standard precautions by
surgical wards nurses had shown in surgical wards.
Recommendations: The study recommended that special education programs can be designed and presented to the
surgical ward nurses and to all the hospital staff in order to increase their awareness towards infection.
A Schiff base ligand (L) was synthesized via condensation of
The aim of this investigation is to evaluate the experimental and numerical effectiveness of a new kind of composite column by using Glass Fiber‐Reinforced Polymer (GFRP) I‐section as well as steel I‐section in comparison to the typical reinforced concrete one. The experimental part included testing six composite columns categorized into two groups according to the slenderness ratio and tested under concentric axial load. Each group contains three specimens with the same dimensions and length, while different cross‐section configurations were used. Columns with reinforced concrete cross‐section (reference column), encased GFRP I‐section, and encased steel I‐section were adopted in each
The fall angle of sun rays on the surface of a photovoltaic PV panel and its temperature is negatively affecting the panel electrical energy produced and efficiency. The fall angle problem was commonly solved by using a dual-axis solar tracker that continually maintains the panel orthogonally positioning to the sun rays all day long. This leads to maximum absorption for solar radiation necessary to produce maximum amount of energy and maintain high level of electrical efficiency. To solve the PV panel temperature problem, a Water-Flow Double Glazing WFDG technique has been introduced as a new cooling tool to reduce the panel temperature. In this paper, an integration design of the water glazing system with a dual-axis tracker has been ac
... Show MoreThis paper reports the effect of Mg doping on structural and optical properties of ZnO prepared by pulse laser deposition (PLD). The films deposited on glass substrate using Nd:YAG laser (1064 nm) as the light source. The structure and optical properties were characterized by X-ray diffraction (XRD) and transmittance measurements. The films grown have a polycrystalline wurtzite structure and high transmission in the UV-Vis (300-900) nm. The optical energy gap of ZnO:Mg thin films could be controlled between (3.2eV and 3.9eV). The refractive index of ZnO:Mg thin films decreases with Mg doping. The extinction coefficient and the complex dielectric constant were also investigate.
When a vehicle is left parked in the sun for an extended period, the gathered heat causes damage to several interiors within the cabin and causes discomfort for people and animals left inside the car. In the present work, the effect of the orientation of a parked white minibus on temperature distribution and cooling load calculation is studied experimentally in an open environment. Two different cases were studied facing south and facing east. For several hours, the temperature inside the car cabin had been monitored and measured at five separate locations. The cooling load calculations are carried out based on the experimental measurements. The results show that the overheating of parked cars always happens as a result
... Show MoreAdsorption capacity of a waste biomass, date stones, for phenolic compounds such as phenol (Ph) and p-nitro phenol (PNPh) was investigated. The characteristics of such waste biomass were determined and found to have a surface area and iodine number of 495.71 m²/g and 475.88 mg/g, respectively. The effects of temperature, initial sorbate concentration, and contact time on the adsorption process were studied. Experimental equilibrium data for adsorption of Ph and PNPh on date stones were analyzed by the Langmuir, Freundlich and Sips isotherm models. The results show that the best fit was achieved with the Sips isotherm equation with maximum adsorption capacities of 147.09 and 179.62 mg/g for Ph and PNPh, respectively. The kinetic data wer
... Show More