Objective: To identify of the effect of the different concentrations of the special liquid (for mixing the investment, Gilvest)
and mixed with water/powder ratio on setting time of phosphate–bonded investment.
Method and materials: The present study is (60) specimens made from phosphate bonded investment divided into (4)
groups (control and experimental groups), (15) specimens for each group. The Gillmore needle device is used to setting
time of phosphate bonded investment mixed with different concentration of Gilvest and water.
Results: Showed that there is a high significant difference (P<0.01) between each groups in the ANOVA test and a
significant difference (P<0.05) between the group (A) and control group in the LSD test.
Recommendations: using other concentration of Gilvest (0.3ml) mixed with water (0.2ml) and powder (15g) on the setting
time of the phosphate–bonded investment. We can use another type of powder (gypsum–bonded investment) with the
Gilvest at different concentrations.
In this research study the effect of fish on the properties optical films thickness 1200-1800 and calculated energy gap Basra direct transport permitted and forbidden to membranes and urged decreasing values ??of Optical Energy Gap increase fish included accounts optical also calculate the constants visual as factories winding down and the refractive index and reflectivity membranes also by real part and imaginarythe dielectric constant
The objective of this research is to identify the effect of Using Fryer strategy on achievement and systemic thinking in the subject of chemistry of second class intermediate school students. The sample of research consisted of 59 students in one intermediate school in Baghdad/Iraq, split into two groups; experimental and control. The scientific material of the study is related to Chapters II and III of the Science Book for the second Intermediate School for the Year (2019-2020). The scientific test is composed of 25 test items whilst the second instrument for research related to systematic thinking test consisted of 12 items. The results of the research showed that the use of Fryer's chemistry-teaching strategy has increased achieve
... Show MoreThe aim of this study is to identify the effect of particle size and to increase the concentration of Iraqi bentonite on rheological properties in order to evaluate its performance and to know if it can be used as drilling fluid without additives or not. In this study, Iraqi bentonite was carried out by mineral composition (XRD), chemical composition (XRF) and Particle size distribution (PSD), and its rheological properties were measured at different particle size and concentration. The results showed that when the particle size of Iraqi bentonite decreased, and the rheological properties were increased with increased concentration of Iraqi bentonite. Also, Iraqi bentonite was unable to use as drilling fluid without certain additives.
... Show MoreTin dioxide doped silver oxide thin films with different x content (0, 0.03, 0.05, 0.07) have been prepared by pulse laser deposition technique (PLD) at room temperatures (RT). The effect of doping concentration on the structural and electrical properties of the films were studied. Atomic Force Measurement (AFM) measurements found that the average value of grain size for all films at RT decrease with increasing of AgO content. While an average roughness values increase with increasing x content. The electrical properties of these films were studied with different x content. The D.C conductivity for all films increases with increasing x content. Also, it found that activation energies decrease with increasing of AgO content for all films.
... Show MoreAbstract: The aim of this study was to evaluate the effect of bone density value in Hounsfield unit derived from cone beam computed tomography (CBCT), and implant dimensions in relation to implant stability parameters namely the resonance frequency analysis and the insertion torque (IT) value. It included 24 patients who received 42 dental implants (DI). The bone density of the planned implant site was preoperatively measured using cone beam computed tomography. The implant stability was measured using Osstell implant stability quotient (ISQ). The ISQ values were recorded immediately postoperatively and after 16 weeks. The IT value was categorized as 35 N/cm or > 35 N/cm. The mean (standard deviation) primary stability was 79.58 (5.27) ISQ,
... Show MoreThe objective of this research is to identify the effect of Using Fryer strategy on achievement and systemic thinking in the subject of chemistry of second class intermediate school students. The sample of research consisted of 59 students in one intermediate school in Baghdad/Iraq, split into two groups; experimental and control. The scientific material of the study is related to Chapters II and III of the Science Book for the second Intermediate School for the Year (2019-2020). The scientific test is composed of 25 test items whilst the second instrument for research related to systematic thinking test consisted of 12 items. The results of the research showed that the use of Fryer's chemistry-teaching strategy has increased achievement an
... Show MoreArab-Islamic architecture has undergone a change at multiple levels affected by modern technology, so the research sought to address the role of contemporary technologies on a fundamental and fundamental component of architecture, which is the architectural space, what is known as the essence of architecture and its ultimate destination, with a focus on the architectural space in the architecture of the contemporary Arab Islamic mosque, because the mosque’s architecture is so important in Islamic law and the belief of the Muslim person himself, where the mosque is the functional style produced by the Islamic faith and embodied in it, whereas, knowing the levels of influence of contemporary technologies in the architectural spac
... Show MoreBackground: Poly-ether-ether-ketone(PEEK) has been introduced to many dental fields. Recently it was tested as a retainer wire‎ following orthodontic treatment. This study aimed to investigate the effect of changing the bonding spot size and location on the performance of PEEK retainer wires. Methods: A biomechanical study involving four three-dimensional finite element models was performed. The basic model was with a 0.8 mm cylindrical cross-section PEEK wire, bonded at the center of the lingual surface of the mandibular incisors with 4 mm in diameter composite spots. Two other models were designed with 3 mm and 5 mm composite sizes. The last model was created with the composite bonding spot of the canine away from the center
... Show More