Abstract
Objective(s): To evaluate housekeeping services staff work environment and their health status, as well as to determine the impact of the work environment upon their health status.
Methodology: A descriptive design is employed throughout the present study to evaluate housekeeping services staff work environment and their health status, as well as to determine the impact of the work environment upon their health status from November 3rd 2017 to June 30th 2018. A purposive “nonprobability” sample of (101) housekeeping staff is selected for the present study. An instrument is constructed for the purpose of the study and it is consists of (2) parts: (I) Evaluation of work environment, and (II) Evaluation of housekeeping staff's health status. A pilot study is conducted for the determination of the instrument’s validity and reliability. The content validity of the instrument is determined by panel of (35) experts. So, the instrument is considered adequately valid measure after performing the modifications that based on the experts’ responses. The internal consistency reliability is determined through split-half technique and the computation of Cronbach alpha correlation coefficient of (r=0.87) which is indicated that the instrument is adequately reliable measure. Data are collected through the use of the study instrument and the structured interview technique as means of data collection. Data are analyzed through descriptive statistical analysis approach of frequency, percentage, mean, total score and range and inferential statistical data analysis approach of linear regression.
Results: The study indicates that the work environment is moderately risky (92.1%) and
the housekeeping staff health status is ranging between fair (42.6%) to good (42.6%) for most of them. The biological, chemical and physical aspects of work environment have great impact upon the housekeeping services staff health status.
Recommendations: The study recommends that work environment can be monitored to maintain occupational health and safety; periodic medical examination has to be initiated and presented to the housekeeping services staff and further research can be conducted on different settings and large sample size.
The design of coordination compounds with solvent-responsive optical properties remains a central challenge in molecular photonics. Here, we describe the synthesis and full characterisation of a symmetrical tetradentate diamine ligand, 3,3′-((1,2-phenylenebis(azanediyl))- bis(methanylylidene))bis(pentane-2,4-dione) (H₂L), and its neutral square-planar complexes [M(L)] (M(II) = Co, Ni, Cu). The Cu(II) complex crystallised as [Cu(L)]⋅0.5 (pyrazine), adopting a nearly square-planar geometry (τ₄ = 0.06) in the solid state, as confirmed by single-crystal X-ray diffraction. In DMSO solution, UV–Vis spectra revealed reversible axial coordination of two solvent molecules, driving a transformation to a distorted octahedral geometry. Struc
... Show MoreThe synthesis of ligands with N2S2 donor sets that include imine, an amide, thioether, thiolate moieties and their metal complexes were achieved. The new Schiff-base ligands; N-(2-((2,4-diphenyl-3-azabicyclo[3.3.1]nonan-9-ylidene)amino)ethyl)-2-((2-mercaptoethyl)thio)-acetamide (H2L1) and N-(2-((2,4-di-p-tolyl-3-azabicyclo[3.3.1]nonan-9-ylidene)amino)ethyl)-2-((2-mercaptoethyl)thio) acetamide (H2L2) were obtained from the reaction of amine precursors with 1,4-dithian-2-one in the presence of triethylamine as a base in the CHCl3 medium. Complexes of the general formula K2<
novel spectrofluorimetric flow injection analysis (FIA) method was developed for the selective quantification of ascorbic acid via fluorescence quenching of serotonin hydrochloride. The system employs a custom-designed photometric array comprising 16 irradiation sources arranged in a dual-axis matrix—eight aligned horizontally and eight orthogonally, enabling multi-angle excitation and enhanced spectral resolution. Fluorescence signals were captured using a twin-pair solar cell detector, offering high sensitivity and minimal optical interference. The method exhibited a linear calibration range of 0.1–30 limit of detection (LOD) of 0.025 μ μ g/mL with a correlation coefficient (r mol /L, equivalent to 4.403 * 10 4 μ 2 ) of 0.9966, a g
... Show MoreBackground: The gene encoding a disintegrin and metalloproteinase domain 33 (ADAM33) is known to be associated with asthma in different ethnic groups. In Iraq, among the Arab ethnic background, this association has not yet been highlighted. Methods: One hundred and ninety-two asthmatics were examined; 118 males and 74 females (mean age 38.23 ± 9.13 years). The control group was 183; 110 males and the rest were females. The SNP of rs2280091 A/G (T1) was studied here to determine adam33 genotyping status using polymerase chain reaction–restriction fragment length polymorphism (PCR–RFLP). The level of total IgE was measured using enzyme-linked immunosorbent assay (ELISA). Results: Significant differences (p = 0.004) in the frequencies of
... Show More