Aim: to determine the effectiveness of women's self-care instructions on their post cesarean section care in Baghdad
teaching hospital.
Methodology: The present study used quasi-experimental study design in maternity words in Baghdad teaching
hospital. The sample was collected and follow up for the period (15) January 2014 until 15 May 2014 Nonprobability
(purposive sample) of (100) women post cesarean section divided in to two groups (50) women post
cesarean section considered as a study group, and another (50) women post cesarean section considered as the
control one, A questionnaire designed as a tool to collect data fit the purpose of the study a questionnaire include
demographic variables, Reproductive variables, instructions self-care post cesarean Wound care, a pilot study was
carried out to test the reliability, As for reliability of questionnaire has been displayed by a group of experts in
various medical specialties and nursing
.Result: The study presents significant differences in implementation of instructional program for self-care
post cesarean between study and control groups on wound, there is significant differences in washing hand
before & after any procedure, Don't put ointment or cream on the wound, don't raise the dressing to see operation
immediately unless done by medical staff (P=0.000). Also significant differences are found in perineal care &
urinary system post cesarean in washing hand before & after using bathroom, wash perineum area water warm
water contains a antiseptics from front of the pubic bone to the anus, place sanitary pads from front to back to
protect the inner surface from contamination, do not hold on the urine when feel the desire to urinate,
practice kegel exercises 2-3 times per day, Do not have sexual intercourse during the first 6 weeks, preferred to
use the western bathroom (P= 0.000).
Recommendations: The study recommended the possibility of providing an educational overlap of self-care
after a cesarean delivery for all pregnant women attending antenatal care centers, primary health, construction
and application of the overlap of the mothers of the educational process to be holding them in the hospital to
increase their knowledge of self-care after a cesarean section
The paper is devoted to solve nth order linear delay integro-differential equations of convolution type (DIDE's-CT) using collocation method with the aid of B-spline functions. A new algorithm with the aid of Matlab language is derived to treat numerically three types (retarded, neutral and mixed) of nth order linear DIDE's-CT using B-spline functions and Weddle rule for calculating the required integrals for these equations. Comparison between approximated and exact results has been given in test examples with suitable graphing for every example for solving three types of linear DIDE's-CT of different orders for conciliated the accuracy of the results of the proposed method.
Mixed ligand metal complexes of CrIII, FeIII,II, NiII and CuII have been synthesized using 5-chlorosalicylic acid (5-CSA) as a primary ligand and L-Valine (L-Val) as secondary ligand. The metal complexes have been characterized by elemental analysis, electrical conductance, magnetic susceptibility measurements and spectral studies. The electrical conductance studies of the complexes indicate their electrolytic nature. Magnetic susceptibility measurements revealed paramagnetic nature of the all complexes. Bonding of the metal ion through –OHand –COOgroups of bidentate to the 5-chlorosalicylic acid and through –NH2 and –COOgroups of bidentate to the L-valine by FT-IR studies . The agar diffusion method has been used to study the antib
... Show MoreEach Intensity Modulated Radiation Therapy (IMRT) plan needs to be tested and verified before any treatment to check its quality. Octavius 4D-1500 phantom detector is a modern and qualified device for quality assurance procedure. This study aims to compare the common dosimetric criteria 3%/3 mm with 2%/2 mm for H&N plans for the IMRT technique. Twenty-five patients with head and neck (H&N) tumor were with 6MV x-ray photon beam using Monaco 5.1 treatment planning software and exported to Elekta synergy linear accelerator then tested for pretreatment verification study using Octavius 4D-1500 phantom detector. The difference between planned and measured dose were assessed by using local and global gamma index (GI) analysis method at
... Show MoreThe goal of this investigation is to prepare zinc oxide (ZnO) nano-thin films by pulsed laser deposition (PLD) technique through Q-switching double frequency Nd:YAG laser (532 nm) wavelength, pulse frequency 6 Hz, and 300 mJ energy under vacuum conditions (10-3 torr) at room temperature. (ZnO) nano-thin films were deposited on glass substrates with different thickness of 300, 600 and 900 nm. ZnO films, were then annealed in air at a temperature of 500 °C for one hour. The results were compared with the researchers' previous theoretical study. The XRD analysis of ZnO nano-thin films indicated a hexagonal multi-crystalline wurtzite structure with preferential growth lines (100), (002), (101) for ZnO nano-thin films with different thi
... Show MoreThis investigation reports application of a mesoporous nanomaterial based on dicationic ionic liquid bonded to amorphous silica, namely nano-N,N,N′,N′-tetramethyl-N-(silican-propyl)-N′-sulfo-ethane-1,2-diaminium chloride (nano-[TSPSED][Cl]2), as an extremely effectual and recoverable catalyst for the generation of bis(pyrazolyl)methanes and pyrazolopyranopyrimidines in solvent-free conditions. In both synthetic protocols, the performance of this catalyst was very useful and general and presented attractive features including short reaction times with high yields, reasonable turnover frequency and turnover number values, easy workup, high performance under mild conditions, recoverability and reusability in 5 consecutive runs without lo
... Show MoreThe electrical insulation of the manufacture sulfonated phenol-formaldehyde viscous material (product) has been studied with Polyvinyl-acetate (PVA) and toluene diisocyanate (TDI) blend has been prepared by fixing percentage by weight 3:1 and mixed with different percentages by weight of the product sulfonated phenol formaldehyde viscous mass (SPF). The Fourier transform infrared (FTIR) spectroscopy is done on (SPF) resin powder and prepared film of PVA-TDI-SPF viscous mass. The quality factor (Q), dissipation factor (D), parallel resistance (Rp), series resistance (Rs), parallel capacitance (Cp), series capacitance (Cs) and phase shift (?) are measured. The calculated maximum dielectric constant (??) is 3.49x107 at sample (1) wt.1% SPF vis
... Show MoreBackground: Oral squamous cell carcinoma represents the vast majority of oral cancer it is a common malignant tumor with an increasing incidence. Around the world, the 5 year mortality rate of oral cancer is about 50%. Thus novel biomarkers for early detection oral squamous cell carcinoma are needed. The level of three salivary microRNAs namely hsa-miR-200a, hsa-miR-125a and hsa- miR-93 were measured in saliva of patients with oral squamous cell carcinoma and compared their levels in saliva of healthy control subjects to determine their potential as oral cancer biomarker. Materials and methods: The level of these three microRNAs was measured by using revers transcription, preamplification and quantitative PCR. Results: Only miR-200a presen
... Show More