Objectives: to compare health of mothers and neonatal among age groups, to find out the correlation between
age groups and mother and neonatal health.
Methodology: A descriptive study was carried out at delivery rooms of three teaching hospitals in Baghdad city
from Feb. 28th through May. 28th
, 2013. A purposive (non-probability) sample of 300 laboring women was selected
from delivery rooms categorized into three groups, group 1 (≤19) years, group 2 their age between (20-35) years
old and group 3 their age (≥35) years. The data were collected through the use of constructing questionnaire, an
interview technique with mothers and reviewing their medical records as means of data collection; The
questionnaire consist of 3 parts: (1) demographic data (2) health of mothers during pregnancy (pregnancy
complications) (3) neonate health status. The validity of the study questionnaire was determined through a panel
of experts and the reliability of the study questionnaire was determine by the application of pilot study.
Descriptive statistical analysis procedure (frequencies and percentages) and inferential data analysis procedure
(chi-square, P-value, split- half approach and Cronbach's Alpha correlation coefficients) were applied for data
analysis.
Results: the finding of the study indicated that the highest percentages of all the study groups were primary school
graduates, urban and housewives. More than half of mothers in group 1 (teenage mothers) and group 2 (20-35)
years were related to their husband, while the highest percentages of mothers in group 3 (advanced maternal age)
were not related to their husband. The highest percentages of complications present in group 1 (teenage mothers)
were anemia, urinary tract infection, multiple pregnancy, Oligohydramnios, poly-hydramnios, intra uterine growth
retardation, Post-term labor, low Apgar score, low birth weight, congenital anomalies, respiratory distrees
syndrome, meconium aspiration syndrome and neonatal death. The highest percentages of complications present
in group 3 (advanced maternal age) were pregnancy induced hypertension, gestational diabetes, antepartum
haemorrhage, pre-term labor, premature rupture of membrane and macrosomia. There is a statistical significant
correlation between age groups and hypertension and preterm, Apgar score, neonatal weight and respiratory
distress syndrome.
Recommendations: Care providers need to be aware about the increasing of obstetrical and neonatal health
complications in the extremities of maternal age (teenage and advanced maternal age) and adjust obstetrical and
neonatal management protocols to ensure optimal maternal and neonatal health
Abstract
The aim of the present work is to control of metal buried corrosion by alteration the media method. This method depended on the characteristics of each media. The corrosion rates in different media (soil, sand, porcelanite stone and gravel) for specimens of low carbon steel were measured by two methods weight loss method and polarization method, weight loss measured by buried specimens in these medias separately for 90 days. The polarization method includes preparing of specimen and salt solutions have electrical resistivity equivalent electrical resistivity of these media. The corrosion rate of two method results in (soil > sand> porcelainte stone> gravel). The lower corrosion rate happene
... Show MoreIn this article the unsteady magnetohydrodynamics oscillating flow of third order fluid with free stream velocity is proposed. It is found that the motion equation is controlled by five dimensionless parameters namely the coecostic parameter 4, viscoelostic parameter ?,acceleration/deceleration c,suction/blowing d and material constants ? . The effect of each of these parameters upon the velocity distribution is analysised
Quadrotors are coming up as an attractive platform for unmanned aerial vehicle (UAV) research, due to the simplicity of their structure and maintenance, their ability to hover, and their vertical take-off and landing (VTOL) capability. With the vast advancements in small-size sensors, actuators, and processors, researchers are now focusing on developing mini UAV’s to be used in both research and commercial applications. This work presents a detailed mathematical nonlinear dynamic model of the quadrotor which is formulated using the Newton-Euler method. Although the quadrotor is a 6 DOF under-actuated system, the derived rotational subsystem is fully actuated, while the translational subsystem is under-actuated. The der
... Show MoreThe present study aims to get experimentally a deeper understanding of the efficiency of carbon fiber-reinforced polymer (CFRP) sheets applied to improve the torsional behavior of L-shaped reinforced concrete spandrel beams in which their ledges were loaded in two stages under monotonic loading. An experimental program was conducted on spandrel beams considering different key parameters including the cross-sectional aspect ratio (
A total of nine swab samples were collected from inflamed teeth and gingiva of human’soral cavity from a dentist clinic in Baghdad. All specimens were cultured in Mitis Salivarius agar medium and the isolated bacterial pure colonies werethen identified by using VITEK2. Three samples were diagnosed and identified as Staphylococcus lentus. One of the three isolates which showed a distinctive heavy growth on the media was selected for further analysis in this study. Paper disk diffusion method was used to detect the antibacterial activityof three of mouthwash solutions (Zak, Colgate and Listerine). The results showed that “Colgate†was the most active solution with antibacterial activity compared with the other two s
... Show MoreDielectric barrier discharges (DBD) can be described as the presence of contact with the discharge of one or more insulating layers located between two cylindrical or flat electrodes connected to an AC/pulse dc power supply. In this work, the properties of the plasma generated by dielectric barrier discharge (DBD) system without and with a glass insulator were studied. The plasma was generated at a constant voltage of 4 kV and fixed distance between the electrodes of 5 mm, and with a variable flow rate of argon gas (0.5, 1, 1.5, 2 and 2.5) L/min. The emission spectra of the DBD plasmas at different flow rates of argon gas have been recorded. Boltzmann plot method was used to calculate the plasma electron temperature (Te), and Stark broadeni
... Show More
