Objective(s): To evaluate nurses' knowledge toward pain management of leukemic child in oncology wards
how were receiving chemotherapy.
Methodology: A descriptive study was conducted in two hospitals on (40) nurses, who provided care for the
children with leukemia in oncology wards (2) hospitals (Children Welfare Teaching Hospital and Child’s Central
Teaching Hospital) in Baghdad city from October 2010 up to the 27th of October 2011 for the purpose of
evaluating their knowledge towards pain management for leukemic child. A purposive "non-probability
sample" was selected that consisted of (40) nurse who are working in oncology wards. A questionnaire format
was used which consist of (2) parts, the first part includes demographic information of the sample and the
second part consists of structured Items concerning nurses' knowledge toward pain management for leukemic
child which includes (3) main sections and comprised of (89) Items. Reliability and validity of questionnaire was
estimated through a pilot study and a panel of expert. The data were analyzed by using descriptive statistical
measures which included frequencies, percentages, and standard deviation, as well as the use of inferential
statistical measures which include the chi- square test.
Results: The results revealed inadequate nurse's knowledge about pain management for leukemic child under
chemotherapy, two third (75 %) of the sample has poor knowledge toward pharmacological and non
pharmacological pain management methods.
Recommendations: Based on the results of research, the study recommends initiating training courses in pain
management and developing pain assessment tools for assessing child's pain and evaluating the level of pain
management procedures
Now-a-days the Flexible AC Transmission Systems (FACTS) technology is very effective in improving the power flow along the transmission lines and makes the power system more flexible and controllable. This paper deals with the most robust type of FACTS devices; it’s a Unified Power Flow Controller (UPFC). Many cases have been taken to study how the system behaves in the presence and absence of the UPFC under normal and contingency conditions. The UPFC is a device that can be used to improve the bus voltage, increasing the loadability of the line and reduce the active and reactive power losses in the transmission lines, through controlling the flow of real and reactive power. Both the magnitude and the phase angle of th
... Show MoreThe effective insulation design of the stress grading (SG) system in form-wound stator coils is essential for preventing partial discharges and excessive heat generation under pulse-width modulation excitation. This paper proposes a method to find the optimal insulation design of the SG system aimed at reducing the dielectric and thermal stresses in the machine coil. The non-uniform transmission line model is used to predict the voltage propagation along the overhang, SG, and slot regions considering the variation in the physical properties of the insulation layers. The machine coil parameters for different insulation materials are calculated by using the finite element method. Two optimization algorithms, fmincon and particle swarm optimiz
... Show MorePhase change materials are extensively studied for use in low-, mid-, and high-temperature applications due to their melting and solidification temperatures, latent heat, and thermophysical properties. This work aims to explore the energy stored, or released and their duration for the energy storage unit formed of a phase change material surrounding a tube within which a hot or cold, single or Two-Phase fluid flows, serving as a heat source or sink. The 3D axial transient thermal analysis of the energy storage unit is performed using the finite element method via a MATLAB-developed computer program. The effects of single- or Two-Phase fluid flow on temperature distribution, solidification, melting duration, and energy stored within phase ch
... Show MoreConcrete columns with hollow-core sections find widespread application owing to their excellent structural efficiency and efficient material utilization. However, corrosion poses a challenge in concrete buildings with steel reinforcement. This paper explores the possibility of using glass fiber-reinforced polymer (GFRP) reinforcement as a non-corrosive and economically viable substitute for steel reinforcement in short square hollow concrete columns. Twelve hollow short columns were meticulously prepared in the laboratory experiments and subjected to pure axial compressive loads until failure. All columns featured a hollow square section with exterior dimensions of (180 × 180) mm and 900 mm height. The columns were categorized into
... Show MoreA simple, low cost and rapid flow injection turbidimetric method was developed and validated for mebeverine hydrochloride (MBH) determination in pharmaceutical preparations. The developed method is based on forming of a white, turbid ion-pair product as a result of a reaction between the MBH and sodium persulfate in a closed flow injection system where the sodium persulfate is used as precipitation reagent. The turbidity of the formed complex was measured at the detection angle of 180° (attenuated detection) using NAG dual&Solo (0-180°) detector which contained dual detections zones (i.e., measuring cells 1 & 2). The increase in the turbidity of the complex was directly proportional to the increase of the MBH concentration
... Show MoreA simple, low cost and rapid flow injection turbidimetric method was developed and validated for mebeverine hydrochloride (MBH) determination in pharmaceutical preparations. The developed method is based on forming of a white, turbid ion-pair product as a result of a reaction between the MBH and sodium persulfate in a closed flow injection system where the sodium persulfate is used as precipitation reagent. The turbidity of the formed complex was measured at the detection angle of 180° (attenuated detection) using NAG dual&Solo (0-180°) detector which contained dual detections zones (i.e., measuring cells 1 & 2). The increase in the turbidity of the complex was directly proportional to the increase of the MBH concentration
... Show MoreThe research included studying the effect of different plowing depths (10,20and30) cm and three angles of the disc harrows (18,20and25) when they were combined in one compound machine consisting of a triple plow and disc harrows tied within one structure. Draft force, fuel consumption, practical productivity, and resistance to soil penetration. The results indicated that the plowing depth and disc angle had a significant effect on all studied parameters. The results showed that when the plowing depth increased and the disc angle increased, leads to increased pull force ratio, fuel consumption, resistance to soil penetration, and reduce the machine practical productivity.
This study was conducted to evaluate the efficacy of 6 isolates of Pseudomonas fluorescens and Trichoderma harzianum and there combination against Fusarium tomato wilt disease caused by Fusarium oxysporum F.sp. Lycopersisi under green house condition .The isolates of bacteria (B3) and Trichoderma (T1) were found to be highly effective in reducing the disease incidence to 13.3% , 21% respectively , compared to control treatment (40%).Furthermore, disease severity was reduced to 28 and 30% respectively in comparison to control (90%) .Colonization of the roots (cfu /g fresh root weight )by the two isolates whether alon or together was extremely high . The combination treatment had a high ability in reducing disease incidenece and sev
... Show MoreGlass fiber–reinforced polymer (GFRP) reinforcement provides an effective alternative to conventional steel in concrete structures due to its corrosion resistance. Nevertheless, the lower elastic modulus of GFRP necessitates careful consideration of serviceability behavior in GFRP-reinforced concrete members. This study presents a numerical sectional analysis model for predicting the flexural response and ultimate capacity of hybrid reinforced concrete beams incorporating embedded GFRP profiles in combination with either mild steel or GFRP reinforcement bars under monotonic static loading. The proposed model employs realistic nonlinear stress–strain relationships for concrete and steel, together with secant moduli of elasticity
... Show More