Preferred Language
Articles
/
ijp-894
Room Temperature Photodetector Based on ANISOTYPE (n-p) Ge-Si Heterojunction
...Show More Authors

In this work we present a detailed study on anisotype nGe-pSi heterojunction (HJ) used as photodetector in the wavelength range (500-1100 nm). I-V characteristics in the dark and under illumination, C-V characteristics, minority carriers lifetime (MCLT), spectral responsivity, field of view, and linearity were investigated at 300K. The results showed that the detector has maximum spectral responsivity at λ=950 nm. The photo-induced open circuit voltage decay results revealed that the MCLT of HJ was around 14.4 μs

View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Sep 27 2023
Journal Name
Journal Of Optics
Studying the responsivity and detectivity of GO/PSi/n-Si photo detector via drop casting technique
...Show More Authors

View Publication
Scopus (4)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Wed Sep 27 2023
Journal Name
Journal Of Optics
Studying the responsivity and detectivity of GO/PSi/n-Si photo detector via drop casting technique
...Show More Authors

View Publication
Scopus (4)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Sun Nov 10 2019
Journal Name
Journal Of Engineering And Applied Sciences
Fabrication and Properties of Ag<sub>2</sub>O/Si Heterojunction Solar Cell Pure and Doped (Sb, Sn and Se)
...Show More Authors

View Publication
Scopus Crossref
Publication Date
Mon Feb 01 2021
Journal Name
Journal Of Engineering
Design narrow-band frequency amplifier (1.5GHz -1.6GHz) based on InGaP Heterojunction Bipolar Transistor (HBT) and GaAs HBT
...Show More Authors

The research aims to design a narrow-band frequency drive amplifier (1.5GHz -1.6GHz), which is used to boost the transmitter amplifier's input signal or amplify the GPS, GlONASS signals at the L1 band.

The Power Amplifier printed circuit board (PCB) prototype was designed using InGaP HBT homogeneous technology transistor and GaAs Heterojunction Bipolar Transistor (HBT) transistor. Two models have been compared; one of the models gave 16dB gain, and the other gave 23dB when using an input power signal (-15dBm). The PCB consumes 2.4W of power and has a physical dimension of 11 x 4 cm.

View Publication Preview PDF
Crossref
Publication Date
Sun Dec 05 2010
Journal Name
Baghdad Science Journal
On Semi-p-Compact Space1
...Show More Authors

The purpose of this paper is to introduce a new type of compact spaces, namely semi-p-compact spaces which are stronger than compact spaces; we give properties and characterizations of semi-p-compact spaces.

View Publication Preview PDF
Crossref
Publication Date
Sun Oct 03 2010
Journal Name
Baghdad Science Journal
On Semi-p-Compact Space
...Show More Authors

Publication Date
Sun Dec 09 2018
Journal Name
Baghdad Science Journal
Conjugated Polymer (MEH-PPV:MWCNTs) Organic Nanocomposite for Photodetector Application
...Show More Authors

Fabrication of a photodetector consists of the conjugated polymer "MEH-PPV"- poly (2-methoxy-5-(2'-ethylhexyloxy)-1,4-phenlenevinylene) and MEH-PPV:MWCNT nanocomposite thin film. The volume ratio investigated was 0.75:0.25. MEH-PPV was dissolved in chloroform solvent and doped with MWCNTs. The spin coating method was used to achieve a facile and low cost photodetector. The absorption spectrum decreases by adding the CNTs. The PL spectrum detected recombination curve results by doping the polymer with CNTs, and AFM measurement showed an increase of roughness average from (0.168 to 2.43nm) of "MEH-PPV" and "MEH-PPV:CNTs", respectively. The doping ratio 0.25, which has a higher photoresponsivity, was evaluated at 1.70 A/W and 2.14 A/W of th

... Show More
View Publication Preview PDF
Scopus (3)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Tue Oct 08 2002
Journal Name
Iraqi Journal Of Laser
Spatial Response Uniformity of Silicon–Based CdS and PbS Heterojunction Laser Detectors
...Show More Authors

This paper demonstrates the spatial response uniformity (SRU) of two types of heterojunctions (CdS, PbS /Si) laser detectors. The spatial response nonuniformity of these heterojunctions is not significant and it is negligible in comparison with p+- n silicon photodiode. Experimental results show that the uniformity of CdS /Si is better than that of PbS /Si heterojunction

View Publication Preview PDF
Publication Date
Sat Mar 01 2008
Journal Name
Iraqi Journal Of Physics
Influence of Gold Concentration on the Main Detection Parameters of Ge-Au Photoconductive Detector
...Show More Authors

Ge-Au infrared photoconductive detection was prepared from germanium single crystal which were doped with different gold concentration using thermal evaporation. The spectral resonsivity (Rλ), spectral detectivity (D*) were determined as function of wavelength, also the resistance, conductivity in dark and with illumination to infrared radiation, the gain and relative photo response have been measured with different gold concentration. Remarkable improvements in the photoresponse gain were observed for the highest resistance specimen at the expense of spectral detectivity values.

View Publication Preview PDF
Publication Date
Thu Jan 16 2020
Journal Name
Indian Journal Of Forensic Medicine & Toxicology
Effect of Addition of Composite Polyamide Micro Particles and Silicone Dioxide NanoParticle on Some Mechanical Properties of Room Temperature Vulcanized Maxillofacial Silicone Elastomer Before and after Artificial Aging
...Show More Authors

Background: The most common reason for re-making a maxillofacial prosthesis is the degradation of the mechanical properties of the silicone. Aim of this study: To assess some mechanical properties of VST-50F maxillofacial silicone reinforced with a composite of silicon dioxide nanoparticle and polyamide-6 microparticle before and after artificial aging. Material and Method: Preparing 240 samples tested for tear strength, tensile strength and elongation percentage, hardness, and roughness before and after aging. The Silicon dioxide was added in concentrations of 1% by weight and Polyamide-6 in the concentration of 0.25% and 0.5% by weight to the VST-50F RTV maxillofacial silicone. The one-way ANOVA and post hoc tests were used for inferentia

... Show More
Preview PDF
Scopus (7)
Scopus