The technical of Flame Thermal Spray had been used in producing a cermet
composite based on powders of stabilized zirconium oxide containing amount of
Yatteria oxide (ZrO2- 8Y2O3) reiforced by minerals powders of bonding material
(Ni-Cr- Al- Y) in different rates of additions (25, 35, 50) on stainless steel base type
(304) after preparing it by the way of Grit Blasting.
Before heat treatment, the coated cermet layers were characterized for porosity
and electric resistivity. All samples were heat treated in vacuum furnace at different
temperature and times. The physical tests had been operated after heat treatment
and gave best results especially porosity, which found to be reduced dramatically
and producing high hardness. The best thickness of coating with bonding material
(25%) was (1.5 mm). The resistivity was found to increase after heat treatment but
it reduces with increasing the amount of self bonding additions
Background: Antibiotic resistance in Escherichia coli is a major concern for public health, as it reduces options to treat infections such at urinary tract infection (UTI). Green tea (Camellia sinensis) and other natural plant products have been of interest for their ability to modify antibiotic susceptibility of bacteria, a capacity largely attributed to bioactive polyphenols. Objective: The purpose of this work was to investigate in vitro the potential effect of green tea leaf ethanol extract on the antibiotic susceptibility of E. coli isolates. Materials and Methods: Green tea leaves was extracted using ethanol and re-dissolved 1% DMSO. Five concentrations of green tea leaves ethanol extract 0.60, 0.50, 0.30, 0.16 and 0
... Show MoreThe objective of the research is to identify the effect of an instructional design according to the active learning modelsالباحثين in the achievement of the students of the fifth grade, the instructional design was constructed according to the active learning models for the design of education. The research experience was applied for a full academic year (the first & the second term of 2017-2018). The sample consisted of 58 students, 28 students for the experimental group and 30 students for the control group. The experimental design was adopted with partial and post-test, the final achievement test consisted of (50) objectives and essays items on two terms, the validity of the test was verified by the adoption of the Kudoric
... Show MoreMany biological tests were done to study the effect of the crude alcoholic leaves extracts on the biological characteristics at the larvae fruit fly Ceratitis capitata with different concentrations of the extracts exposed 1,2,3,5 and 7.5 % at constant laboratory conditions includes the temperature and the relative humidity (27±2C0&70±5 % respectively). The results of the experiments showed that the alcoholic extracts of the plant effected the growth and the development of the larvae and pupae according to the concentrations . The alcoholic extracts proved to have the highest mortality tend to 66.76 % in larva treated with alcoholic at concentration 7.5 % the
... Show MoreThis experiment was carried out at the Field of Poultry, Department of Animal Resources, College of Agriculture, University of Baghdad, during the period from 1/5/2011 until 5/7/2011 to study the effect of adding arginine to laying hens diet on certain blood traits. A total of 100 Brown Lohmann laying hen chickens, 38 weeks of age, were randomly distributed into four treatment groups, with 25 hens for each treatment. Treatment groups were: T1: bird-fed diet with no additional arginine (control group); T2, T3, and T4: bird-fed diet supplemented with 0.4, 0.7, and 0.9%, respectively. Therefore, the total amounts of arginine in the four treatments (T1, T2, T3, and T4) become 1.1, 1.5, 1.8, and 2.0%, respectively. Results of this experiment rev
... Show MoreIn a hybrid cooling solar thermal systems , a solar collector is used to convert solar energy into heat energy in order to super heat the refrigerant leaving the compressor, and this process helps in the transformation of refrigerant state from gaseous state to the liquid state in upper two-thirds of the condenser instead of the lower two-thirds such as in the traditional air-conditioning systems and this will reduce the energy needed to run the process of cooling .In this research two systems with a capacity of 2 tons each were used, a hybrid air-conditioning system with an evacuated tubes solar collector and a traditional air-conditioning system . The refrigerant of each type was R22.The comparison was in the amou
... Show More