Preferred Language
Articles
/
ijp-846
Night Vision monitor for IR laser spot size Identification
...Show More Authors

The aim of this research is to design and construct a
semiconductor laser range finder operating in the near infrared range
for ranging and designation. The main part of the range finder is the
transmitter which is a semiconductor laser type GaAs of wavelength
0.904 μm with a beam expander and the receiver; a silicon pin
detector biased to approve the fast response time with it's collecting
optics. The transmitters pulse width was 200ns at a threshold current
of 10 Ampere and maximum operating current of 38 Ampere. The
repetition rate was set at 660Hz and the maximum operating output
power was around 1 watt. The divergence of the beam was 0.268o
the efficiency of the laser was 0.03% at a duty cycle of 1.32x10-4.
Special software (ZEMAX EE 2000) was implemented for optimum
optical design.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Nov 08 2018
Journal Name
Iraqi National Journal Of Nursing Specialties
Health- related quality of life for adult patient with chronic viral hepatitis B and C
...Show More Authors

Objective(s): This study aims to assess health related quality of life among Iraqi patients with chronic viral hepatitis
B and C also to find out the relationship between health related quality of life and patients demographic
characteristic and to design a new measurement scale for assessing QoL among viral hepatitis B and C patients
which can be suitable to be adopted for Iraqi patients
Methodology: A descriptive quantitative study is carried out at Gastroenterology and Hepatology Teaching
Hospital from February, 1st, 2011 to August 30th 2011, Anon probability (purposive sample) of (100) chronic viral
hepatitis B and C persons , who were clients of Gastroenterology and Hepatology Teaching Hospital / outpatient
clin

... Show More
View Publication Preview PDF
Publication Date
Sun Feb 10 2019
Journal Name
Iraqi National Journal Of Nursing Specialties
Functional Performance For Patients Post Heart's Valves Replacement at Cardiac Surgery Centers in Baghdad City
...Show More Authors

Abstract
Objectives: The study is carried out to assess functional performance for heart's valve replacement patients and find out relationship with sociodemographic data and clinical data
Methodology: Descriptive design is carried out at cardiac surgery centers in Baghdad ; Ibn -Al Betar Specialized for cardiac surgery center and Al-Iraqi center for cardiac disease. its initiation from December28the 2013 to September 1st 2014,A non- probability (purposive) sample of 50 adults patients are attended cardiac surgery centers at Baghdad city and who have heart valves replacement. The data collection through development of questionnaire which is composed from three parts(socio demographic data, clinical information, functional performa

... Show More
View Publication Preview PDF
Publication Date
Fri May 01 2020
Journal Name
International Journal Of Geomate
METHODOLOGY FOR MONITORING THE FLEXURAL BEHAV-IOR OF STRUCTURAL CONCRETE MEMBERS WITH UNBONDED INTERNAL STEEL
...Show More Authors

View Publication
Scopus (1)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Mon Mar 01 2021
Journal Name
Journal Of Management In Engineering
Identifying Pertinent Indicators for Assessing and Fostering Diversity, Equity, and Inclusion of the Construction Workforce
...Show More Authors

View Publication
Scopus (77)
Crossref (75)
Scopus Clarivate Crossref
Publication Date
Sat Mar 23 2024
Journal Name
Journal Of Optics
Tapered single-mode no-core optical fiber sensor coated with layer gold for hemoglobin sensing
...Show More Authors

The present work focuses on the experimental implementation of one of the fiber optical sensors, the optical glass fiber built on surface Plasmon resonance. A type of optical glass fiber was used in this work, single-mode no-core fiber with pre-tapering diameter: (125.1 μm) and (125.3 μm), respectively. The taper method can be tested by measuring the output power of the optical fiber before and after chemical etching to show the difference in cladding diameter due to the effect of hydrofluoric acid with increasing time for the taper process. The optical glass fiber sensor can be fabricated using the taper method to reduce the cladding diameter of the fibers to (83.12 µm, 64.37 µm, and 52.45 µm) for single-mode fibers using Hydrofluoric

... Show More
View Publication Preview PDF
Scopus (5)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Sun Mar 15 2020
Journal Name
Al-academy
Designing Interactive Educational Website for Highschool Students in Iraq: أحمد ناجي علي-يوسف مشتاق لطيف
...Show More Authors

       publishing has become a large space in the field of interactive education and modern  pages have become dedicated to the service of the educational effort in this area as the research in this context of the urgent scientific necessities, especially as we consider in Iraq from the new countries in the exploitation of these new technologies and investment possibilities of the information network And the contents of different in the framework of so-called distance education Here lies the problem of research in the possibility of finding scientific solutions for the design of interactive inter active website for students of the preparatory stage in Iraq and to find out the scientific ways to find des

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Feb 24 2023
Journal Name
Membranes
Enhanced Antifouling in Flat-Sheet Polyphenylsulfone Membranes Incorporating Graphene Oxide–Tungsten Oxide for Ultrafiltration Applications
...Show More Authors

In this study tungsten oxide and graphene oxide (GO-WO2.89) were successfully combined using the ultra-sonication method and embedded with polyphenylsulfone (PPSU) to prepare novel low-fouling membranes for ultrafiltration applications. The properties of the modified membranes and performance were investigated using Fourier-transform infrared spectroscopy (FT-IR), scanning electron microscopy (SEM), contact angle (CA), water permeation flux, and bovine serum albumin (BSA) rejection. It was found that the modified PPSU membrane fabricated from 0.1 wt.% of GO-WO2.89 possessed the best characteristics, with a 40.82° contact angle and 92.94% porosity. The permeation flux of the best membrane was the highest. The pure water permeation f

... Show More
View Publication
Scopus (28)
Crossref (25)
Scopus Clarivate Crossref
Publication Date
Tue Feb 01 2022
Journal Name
Advanced Powder Technology
Functionalization of mesoporous MCM-41 for the delivery of curcumin as an anti-inflammatory therapy
...Show More Authors

View Publication
Scopus (99)
Crossref (98)
Scopus Clarivate Crossref
Publication Date
Tue Oct 17 2023
Journal Name
International Journal Of Renewable Energy Development
The feasibility of utilizing microwave-assisted pyrolysis for Albizia branches biomass conversion into biofuel productions
...Show More Authors

The consumption of fossil fuels has caused many challenges, including environmental and climate damage, global warming, and rising energy costs, which has prompted seeking to substitute other alternative sources. The current study explored the microwave pyrolysis of Albizia branches to assess its potential to produce all forms of fuel (solid, liquid, gas), time savings, and effective thermal heat transfer. The impact of the critical parameters on the quantity and quality of the biofuel generation, including time, power levels, biomass weight, and particle size, were investigated. The results revealed that the best bio-oil production was 76% at a power level of 450 W and 20 g of biomass. Additionally, low power levels led to enhanced

... Show More
View Publication
Scopus (15)
Crossref (8)
Scopus Clarivate Crossref
Publication Date
Sun Jan 01 2023
Journal Name
Alexandria Engineering Journal
Calcium/iron-layered double hydroxides-sodium alginate for removal of tetracycline antibiotic from aqueous solution
...Show More Authors

Crossref (41)
Crossref