Preferred Language
Articles
/
ijp-837
Inelastic magnetic electron scattering M1 form factors in Ca-48 (M3Y fitting parameters consideration)
...Show More Authors

Inelastic magnetic electron scattering M1 at Ex =10.23 MeV form factors in Ca-48 have been investigated. The fp shell model space with four orbits and eight neutrons have been considered and FPD6 has been selected between 32 model space effective interactions to generates the model space vectors for the M1 transition with excitation energy Ex =10.23 MeV and for constructing OBDM. Discarded space (core and higher configuration orbits) has been included through the first order perturbation theory to couple the partice-hole pair of excitation in the calculation of the total M1 form factor and regarding the realistic interaction M3Y as a core polarization interaction with six sets of fitting parameters. Finally the theoretical calculations have been consisted with the experimental data for such transition form factor

View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Jun 01 2023
Journal Name
Optik
Combination of near-field and scattering effects in plasmonic perovskite solar cell including cobalt doped nickel oxide HTL
...Show More Authors

View Publication
Scopus (12)
Crossref (10)
Scopus Clarivate Crossref
Publication Date
Wed Dec 18 2019
Journal Name
Baghdad Science Journal
E4An Ultrastructural Study by Transmission Electron Microscope of Exocrine Pancreatic Cells in Diabetic Rats Treated with Herbal Combination
...Show More Authors

     The current study was designed to investigate the alterations in the ultrastructure of orgenelles and cellular activity of exocrine pancreatic acini of experimentally induced-diabetic rats and to assess the usefulness of herbal combination supplementation in improving the ultrastructure and cellular activity of exocrine pancreas. The number of albino male rats used were 24 which divided into equally 4 groups; group I: control group, group II: alloxan-induced diabetes mellitus (single intraperitoneal dose of alloxan 120 mg/kg for 3 days), group III: herbal combination treatment composed from the extracts of fenugreek seeds (Trigonella foenum-graecum), black cumin (Nigella sativa) seeds, rhizomes

... Show More
View Publication Preview PDF
Scopus (3)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Mon Dec 03 2018
Journal Name
Journal Of Engineering
Variable Structure Control Design for a Magnetic Levitation System
...Show More Authors

In this paper the variable structure control theory is utilized to derive a discontinuous controller to the magnetic levitation system. The magnetic levitation system model is considered uncertain, which subjected to the uncertainty in system parameters, also it is open-loop unstable and strongly nonlinear. The proposed variable structure control to magnetic levitation system is proved, and the area of attraction is determined. Additionally, the chattering, which induced due to the discontinuity in control law, is attenuated by using a non-smooth approximate. With this approximation the resulted controller is a continuous variable structure controller with a determined steady state error according to the selected control

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Fri Feb 17 2012
Journal Name
Smart Materials And Structures
Frequency tuning of piezoelectric energy harvesters by magnetic force
...Show More Authors

View Publication
Scopus (112)
Crossref (102)
Scopus Clarivate Crossref
Publication Date
Mon Feb 01 2021
Journal Name
Materials Science And Engineering
Effect of magnetic water on strength properties of concrete
...Show More Authors
Abstract<p>The research’s main goal is to investigate the effects of using magnetic water in concrete mixes with regard to various mechanical properties such as compressive, flexural, and splitting tensile strength. The concrete mix investigated was designed to attain a specified cylinder compressive strength (30 MPa), with mix proportions of 1:1.8:2.68 cement to sand to crushed aggregate. The cement content was about 380 kg/m<sup>3</sup>, with a w/c ratio equal to 0.54, sand content of about 685 kg/m3, and gravel content of about 1,020 kg/m3. Magnetic water was prepared via passing ordinary water throughout a magnetic field with a magnetic intensity of 9,000 Gauss. The strength test</p> ... Show More
Crossref (7)
Crossref
Publication Date
Mon Mar 23 2020
Journal Name
Journal Of Engineering
Post-buckling Analysis of Cold-form Steel Column
...Show More Authors

For the time being, the cold-formed sections are widely used due to their simple manufacturing and construction processes. To be feasible, the strength of cold-formed columns should be determined based on their post-buckling behavior. Post-buckling relations are cumbersome and need design aids similar to those of American Iron and Steel Institute (AISI) to be applicable. These design aids have been developed to sections and materials other than those available in the local market. Therefore, this paper tries to develop a general finite element model to simulate the postbuckling behavior of cold-formed steel columns. Shell element has been used to discretize the web, flanges, and lips of the column. A linear bucking analy

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Tue Sep 01 2020
Journal Name
Journal Of Engineering
Urban Form Elements and Urban Potentiality ( Literature Review)
...Show More Authors

Morphological theories shape the leading platform to theoretically and practically consider the assets connected with the emergence of the city, and its growth and development over time. In this paper, five elements of the urban form are typified: structure/tissue, plot, building, block, and the street pattern will be addressed. Understanding the urban form at the different levels within its ingredients could lead to shape a base launch of how to consider the potentiality of the development and sustainability of a particular area.   

View Publication Preview PDF
Crossref (9)
Crossref
Publication Date
Wed Mar 01 2023
Journal Name
Baghdad Science Journal
Pharmacokinetic Consideration to Formulate Sustained Release Drugs: Understanding the Controlled Drug Diffusion through the Body Compartment of the Systemic Circulation and Tissue Medium-A Caputo Model
...Show More Authors

The aim of this study is to provide an overview of various models to study drug diffusion for a sustained period into and within the human body. Emphasized the mathematical compartment models using fractional derivative (Caputo model) approach to investigate the change in sustained drug concentration in different compartments of the human body system through the oral route or the intravenous route. Law of mass action, first-order kinetics, and Fick's perfusion principle were used to develop mathematical compartment models representing sustained drug diffusion throughout the human body. To adequately predict the sustained drug diffusion into various compartments of the human body, consider fractional derivative (Caputo model) to investiga

... Show More
View Publication Preview PDF
Scopus (3)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Thu Jan 30 2020
Journal Name
Neuroquantology
Studying Effect of Temperature on Electron Transport Parameter and Coefficients in CF3I Mixture with N2O
...Show More Authors

View Publication
Scopus (1)
Scopus Crossref
Publication Date
Fri Feb 01 2019
Journal Name
Construction And Building Materials
Utilization of magnetic water in cementitious adhesive for near-surface mounted CFRP strengthening system
...Show More Authors

Cement-based adhesive (CBA) is used as a bonding agent in Carbon Fibre Reinforced Polymer (CFRP) applications as an alternative to epoxy-based adhesive due to the drawbacks of the epoxy system under severe service conditions which negatively affect the bond between the CFRP and strengthened elements. This paper reports the results of, an investigation carried out to develop two types of CBA using magnetized water (MW) for mixing and curing. Two magnetic devices (MD-I and MD-II), with different magnetic field strengths (9000 and 6000 Gauss) respectively, were employed for water magnetization. Different water flows with different water circulation times in the magnetizer were used for each device. Compressive and splitting tensile strength te

... Show More
Scopus (12)
Crossref (11)
Scopus Clarivate Crossref