The Boltzmann transport equation is solved by using two- terms approximation for pure gases . This method of solution is used to calculate the electron energy distribution function and electric transport parameters were evaluated in the range of E/N varying from . 172152110./510.VcmENVcm
From the results we can conclude that the electron energy distribution function of CF4 gas is nearly Maxwellian at (1,2)Td, and when E/N increase the distribution function is non Maxwellian. Behavior of electrons transport parameters is nearly from the experimental results in references. The drift velocity of electron in carbon tetraflouride is large compared with other gases
The Estimation Of The Reliability Function Depends On The Accuracy Of The Data Used To Estimate The Parameters Of The Probability distribution, and Because Some Data Suffer from a Skew in their Data to Estimate the Parameters and Calculate the Reliability Function in light of the Presence of Some Skew in the Data, there must be a Distribution that has flexibility in dealing with that Data. As in the data of Diyala Company for Electrical Industries, as it was observed that there was a positive twisting in the data collected from the Power and Machinery Department, which required distribution that deals with those data and searches for methods that accommodate this problem and lead to accurate estimates of the reliability function,
... Show MoreThe DC electrical conductivity properties of Ge60Se40-xTex alloy with x = 0, 5, 10, 15 and 20). The samples were formed in the form of discs with the thickness of 0.25–0.30 cm and the diameter of 1.5 cm. Samples were pressed under a pressure of 6 tons per cm2 , using a ton hydraulic press. They were prepared after being pressed using a ton hydraulic press using a hydraulic press. Melting point technology use to preper the samples. Continuous electrical conductivity properties were recorded from room temperature to 475 K. Experimental data indicates that glass containing 15% Te has the highest electrical conductivity allowing maximum current through the sample compared to Lu with other samples. Therefore, it is found that the DC co
... Show MoreThe corrosion inhibition effect of a new furan derivative (furan-2-ylmethyl sulfanyl acetic acid furan-2-ylmethylenehydrazide) on mild steel in 1.0 M HCl was investigated using corrosion potential (ECORR) and potentiodynamic polarization. The obtained results indicated that the new furan derivative (furan-2-ylmethyl sulfanyl acetic acid furan-2-ylmethylenehydrazide) (FSFD) has a promising inhibitive effects on the corrosion of mild steel in 1.0 M HCl across all of the conditions examined. The density functional theory (DFT) study was performed on the new furan derivative (FSFD) at the B3LYP/6-311G (d, p) basis set level to explore the relation between their inhibition efficiency and molecular electro
Abstract
The miraculous of al-Quran has been surrounded by the attention of scholars, as it is the one that has astonished the rhetoricians with its eloquence. So , they paid attention to every part of it and hugely they studied it with accuracy in respect to its Surah ad Ayahs. It is considered the most important source from which Arab scholars and early grammarians drew, given their unanimity that it is the highest degree of eloquence and the best record of the common literary language.
Among these sciences is the science of Grammar, and without Qur’an, this science would not have emerged, which later had control over every science of Arabic
... Show More
Diyala River is one of the important rivers that provide water for the Governorate of Diyala. In this research, the morphology and sediment transport of this river were studied using HEC-Ras software. The selected length of the river in the present study is 193 km and extended from Diyala Weir to the confluence of Tigris River and Diyala River. The fieldwork period extended from June 2020 till August 2020, where suspended-load and bed-load samples were collected and surveyed some cross-sections. The one-dimensional sediment transport model has been calibrated for five years, from 2014 to 2019. The results were compared with the measured cross-sections in 2019, and the suitable value of (maximum depth
... Show MoreAim: The aim of this study is to determine the correlation between levels of certain seminal biochemical parameters and serum reproductive hormones, on the one hand, and sperm function tests, on the other hand, in asthenospermic patients. Patients and Methods: Sixty asthenospermic patients and twenty fertile men as a control group were included in this study. Semen samples were collected to perform seminal fluid analysis. Total protein, cholesterol, calcium, creatine kinase, and fructose were measured in the seminal plasma. Blood samples were collected for hormonal assay of serum reproductive hormones: testosterone, prolactin, luteinizing hormone, and follicle-stimulating hormone. Results: The results revealed a significant positive correla
... Show MoreAn experiment was carried out in the vegetables field of Horticulture Department / College of Agriculture / Baghdad University , for the three seasons : spring and Autumn of 2005 , and spring of 2007 , to study the type of gene action in some traits of vegetative , flowery growth , yield and its components in summer squash crosses (4 x 3 = cross 1 , 3 x 7 = cross 2 , 3 x 4 = cross 3 , 3 x 5 = cross 4 , 5 x 1= cross 5 , 5 x 2 = cross 6). The study followed generation mean analysis method which included to each cross (P1 , P2 , F1 , F2 , Bc1P1 , Bc1P2) , and those populations obtained by hybridization during the first and second seasons. Experimental comparison was performed in the second (Two crosses only) and third seasons , (four crosses)
... Show MoreKA Hadi, AH Asma’a, IJONS, 2018 - Cited by 1
Abstract- Plasma parameters in a planar dc-sputtering discharge in argon were measured by cylindrical electrostatic probe (Langmuir probe).Electron density, electron temperature, floating potential, and space potential were monitored as a function of working discharge pressure. Electrostatic probe and supporting circuit were described and used to plot the current – voltage characteristics. Plasma properties were inferred from the current-voltage characteristics of a single probe positioned at the inter-cathode space. Typical values are in the range of (10-16 -10-17) m-3 and (2.93 – 5.3) eV for the electron density and the electron temperature respectively.