Preferred Language
Articles
/
ijp-816
Measurement of Background Radioactivity in Baghdad's Main Water Supply Stations: Sediment Samples
...Show More Authors

Sediment samples were collected from main water processing and supply plants in Baghdad, and tested for radioactivity from both natural and artificial sources. These stations are: East Dijla (Tigris), Al-Kadisia, Al-Karama, Al-Rasheed, Al-Sader, Al-Wathba, and Al-Wihda supply stations. Qualitative measurements were made, and the results showed that most sediments exhibited natural radioactive level and sometimes less than the international regular standards. Specially, K-40 and Ra-226 results were much less than the standards for radioactive concentrations. Ac-228 concentration was found rather than Th-232 (in Al-Sader and Al-Wihda samples) but with low concentrations of about 10-15 Bg/kg and detection confidence ~45% , and Ce-141 and Be-7 both with concentration less than 5 Bq/kg but with confidence ~90%. Cs-137 was detected in 6 of these samples with concentrations varied from 0.84 to 10.42 Bq/kg. All samples measurements were within standard limits providing acceptable radioactivity levels.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Jan 09 2008
Journal Name
Iraqi Journal Of Agricultural Sciences 39 (3)‏
IFNFLUENCES OF IRRIGATION WITH MAGNETIZED WATER AND FOLIAR FERTILIZATION IN MINERAL CONTENTS OF ORANGE LEAVES.‏
...Show More Authors

Publication Date
Wed Jan 01 2014
Journal Name
Current Research In Microbiology And Biotechnology
Cytogenetic Analysis for the Effect of Alcoholic and Water Extracts of Iraqi Propolis in Mice
...Show More Authors

This study was conducted to study the cytogenetic effect of both alcoholic and water extracts of propolis on mice. Three different samples of propolis were collected from three different regions of Iraq (Najaf, Arbil and Baghdad) to be used in this study. The cytotoxic effect of two different doses of each extracted sample was measured by employing cytogenetic analysis which included (mitotic index (MI), chromosomal aberrations (CAs), micronucleus index (MN) and sperm abnormalities). Results showed that significant increase in MI and significant reduction in MN, CAs and sperm abnormalities percentage were seen after treatment with both alcoholic and water extract of the three samples when compared with negative control, and alcoholic extrac

... Show More
Publication Date
Fri Jan 01 2021
Journal Name
E3s Web Of Conferences
Assessment of Water Quality in Tigris River of AL-Kut City, Iraq by Using GIS
...Show More Authors

The concerns about water contaminants affect most developing countries bypassing rivers over them. The issue is challenging to introduce water quality within the allowed limits for drinking, industrial and agricultural purposes. In the present study, physical-chemical parameters measurements of water samples taken from eleven stations were collected during six months in 2020 through flow path along the whole length of Tigris River inside AL Kut city (center of Wassit government) were investigated for six parameters are total hardness TH, hydrogen ion pH, biological oxygen demand BOD5, total dissolved solids TDS, nitrate NO3, and sulfate SO4. The water quality analysis results were compared with the maximum allowable limit concentrat

... Show More
Scopus (6)
Crossref (3)
Scopus Crossref
Publication Date
Fri Jan 01 2021
Journal Name
Aip Conference Proceedings
Radon concentrations assessment in tap water for different areas in Baghdad city using Rad7
...Show More Authors

View Publication
Scopus (1)
Scopus Crossref
Publication Date
Wed Jun 30 2004
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Removal of Emulsified Kerosene from Water by Flotation
...Show More Authors

View Publication Preview PDF
Publication Date
Mon Jan 01 2024
Journal Name
Iraqi Journal Of Applied Physics
Fabrication of PAN:Cellulose Membrane for Oil/Water Separation
...Show More Authors

In this study, we fabricated nanofiltration membranes using the electrospinning technique, employing pure PAN and a mixed matrix of PAN/HPMC. The PAN nanofibrous membranes with a concentration of 13wt% were prepared and blended with different concentrations of HPMC in the solvent N, N-Dimethylformamide (DMF). We conducted a comprehensive analysis of these membranes' surface morphology, chemical composition, wettability, and porosity and compared the results. The findings indicated that the inclusion of HPMC in the PAN membranes led to a reduction in surface porosity and fiber size. The contact angle decreased, indicating increased surface hydrophilicity, which can enhance flux and reduce fouling tendencies. Subsequently, we evaluated the e

... Show More
Scopus
Publication Date
Tue Dec 01 2015
Journal Name
Journal Of Environmental Engineering And Science
Soybean peroxidase-catalysed removal of benzidines from water
...Show More Authors

Crude soybean peroxidase (SBP), isolated from soybean seed coats (hulls) at unusually low concentrations, catalyses the oxidative polymerisation of hazardous aqueous benzidine and its 3,3′-dichloro, 3,3′-dimethyl and 3,3′-dimethoxy derivatives in the presence of hydrogen peroxide. The optimum operating conditions for oxidation of 0·10 mM benzidine were investigated. At pH 5, the hydrogen peroxide-to-substrate concentration ratio was 1·5 and the minimum SBP concentration required to achieve at least 95% conversion of the benzidine in synthetic wastewater was 0·43 mU/ml. Progress curves were established for the conversion of the four substrates, and apparent first-order rate constants were derived. Enzyme-catalysed polym

... Show More
View Publication
Scopus (12)
Crossref (10)
Scopus Crossref
Publication Date
Mon Jan 07 2019
Journal Name
Drinking Water Engineering And Science Discussions
De-chlorination of drinking water by forced aeration
...Show More Authors

Abstract. Shock chlorination is a well-known practice in swimming pools and domestic wells. One of the limitations for using this technique in drinking water purification facilities is the difficulty of quickly removing high chlorine concentrations in water distribution systems or production facilities. In order to use this method in the drinking water industry a shock de-chlorination method should be introduced for producing microorganism and biocide free water. De-chlorination using natural stagnant aeration (leaving the water to lose the chlorine naturally) is the safest known method if compared with chemical and charcoaling methods. Unfortunately, stagnant aeration is a slow process. Therefore, developing a process for accelerat

... Show More
View Publication
Crossref (2)
Crossref
Publication Date
Fri Jan 04 2019
Journal Name
Drinking Water Engineering And Science Discussions
Bio-purification of drinking water by froth flotation
...Show More Authors

Abstract. The main technique for removing bacteria from water for various applications is chemical disinfection. However, this method has many disadvantages such as producing disinfectant by-products (DBPs), biofilm formation and either rendering the water unpotable (at high residual disinfection) or leaving a potential for lethal diseases such as Cholera (if the residual disinfection is too low). Recently, a process was developed for continuous removal of bacteria from water using the principle of froth flotation through compressed air only without any chemicals (Hassan, 2015). This work examines the extent to which chemical free froth flotation can purify drinking water. The experiments were carried out using two flotation columns

... Show More
View Publication
Crossref
Publication Date
Sun Jul 31 2022
Journal Name
Iraqi Geological Journal
A Review of Historical Studies for Water Saturation Determination Techniques
...Show More Authors

Water saturation is the most significant characteristic for reservoir characterization in order to assess oil reserves; this paper reviewed the concepts and applications of both classic and new approaches to determine water saturation. so, this work guides the reader to realize and distinguish between various strategies to obtain an appropriate water saturation value from electrical logging in both resistivity and dielectric has been studied, and the most well-known models in clean and shaly formation have been demonstrated. The Nuclear Magnetic Resonance in conventional and nonconventional reservoirs has been reviewed and understood as the major feature of this approach to estimate Water Saturation based on T2 distribution. Artific

... Show More
View Publication Preview PDF
Scopus (4)
Scopus Crossref