Non thermal argon plasma needle at atmospheric pressure was generated. The experimental set up is based on very simple and low cost electric components that generate electrical field sufficiently high at the electrodes to ionize various gases, which flow at atmospheric pressure. The high d.c power supply is 7.5kV peak to peak, the frequency of the electrical field is 28kHz, and the plasma power less than 15W. The plasma is generated using only one electrode. In the present work the voltage and current discharge waveform are measured. Also the temperature of the working Ar gas at different gas flow and distances from the plasma electrode tip was recorded
Thin films ZrO2: MgO nanostructure have been synthesized by a radio frequency magnetron plasma sputtering technique at different ratios of MgO (0,6, 8 and 10)% percentage to be used as the gas sensor for nitrogen dioxide NO2. The samples were investigated by X-ray diffraction (XRD), atomic force microscopy (AFM), scanning electron microscopy (SEM), energy-dispersive X-ray (EDX) and sensing properties were also investigated. The average particle size of all prepared samples was found lower than 33.22nm and the structure was a monoclinic phase. The distribution of grain size was found lower than36.3 nm and uninformed particles on the surface. Finally, the data of sensing properties have been discussed, where the
... Show MoreThere is a great risk of cardiovascular disease (CVD) and vascular thrombosis in patients with End-Stage Renal Disease (ESRD). These patients exhibit numerous abnormalities in coagulation, fibrinolytic, inhibitory protein abnormalities in multiple levels. The study aimed to assess hypercoagulable changes by measuring the levels of antithrombin, plasma fibrinogen and FXII activity in patients with ESRD, and to find their correlation with Hemoglobin (Hb) level, WBC count, reticulocyte percentage and platelet count. This study was conducted at Al-Hayat center, Al Karama Teaching Hospital on 50 ESRD patients aged < 60 years of both genders. In addition, 20 apparently healthy individuals were included as a control group. The mean Hb level, total
... Show MoreIn the present study, free convection heat and mass transfer of fluid in a square packed bed enclosure is numerically investigated. For the considered geometrical shape, the left vertical wall of enclosure was assumed to be kept at high temperature and concentration while the opposite wall was kept at low temperature and concentration with insulating both the top and bottom walls of enclosure. The Brinkman– Forchheimer extended Darcy model was used to solve the momentum equations, while the energy equations for fluid and solid phases were solved by using the local thermal non-equilibrium (LTNE) model.Computations are performed for a range of the Darcy number from 10-5 to 10-1, the porosity from 0.5 to 0.9, and buoyancy ratio from -15 t
... Show MoreOmentin (or intelectin) is a main visceral fat secretory adipokine. There is a growing interest to link omentin, obesity and co-morbidity factors. The aim of the present study is to evaluate serum omentin and its association to insulin resistance biomarkers, lipid profile and atherogenic indies. This cross – sectional study was conducted in Obesity Research and Therapy Unit-Alkindy College of Medicine by recruiting (115) individuals; 49 males /66 females. Subjects between (20 to 60) years of age were selected and classified into two groups according to their Body mass index (BMI). Group1 involved healthy lean volunteers (25 male/ 36 female; BMI 18.5 - 24.9). Group2 involved obese subjects; (24 male / 36 female with BMI ≥ 30). The s
... Show More|
Natural convection in an annular space provided with metal foam fins attached to the inner cylinder is studied numerically. The metal foam fins made of copper were inserted in different axial sections with three fins in each section. The temperature of the inner cylinder is kept constant while the annular outer surface is adiabatic. The thickness effect of the inner pipe wall was considered. Naiver Stokes equation with Boussinesq approximation is used for the fluid regime while Brinkman-Forchheimer Darcy model is used for metal foam. In addition, the local thermal non-equilibrium condition in the energy equation of the porous media is presumed. The effect of Rayleigh numb |
Steady natural and mixed convection flow in a square vented enclosure filled with water-saturated aluminum metal foam is numerically investigated. The left vertical wall is kept at constant temperature and the remaining walls are thermally insulated. Forced convection is imposed by providing an inlet at cavity bottom surface, and a vent at the top surface. Natural convection takes place due to the temperature difference inside the enclosure. Darcy-Brinkman-Forchheimer model for fluid flow and the two-equation of the local thermal non-equilibrium model for heat flow was adopted to describe the flow characteristics within the porous cavity. Numerical results are obtained for a wide range of width of the inlet as a fraction
... Show MoreThe increasing level of residents’ requirements of the local community led to the necessity for sufficient local funding to satisfy the residents’ requirements and services of the local units affiliated with the decentralized administrative systems on the one hand, and to the role of local financing in the financial independence of local units on the other hand.With the presence of local financing, the financial independence of local units is achieved and is considered one of the conditions for financial independence, which is the provision of local financing to the units away from central support. The study focused in this research to clarify the concept of local financing for local units with a statement of its conditions and importan
... Show Moreأختبرت في هذه الدراسه حساسيه اختبار فرط الحساسية المتأخر وعلاقته ببعض معايير الخمج باللشمانيا في مجموعتين من حيوانات الهامستر المحقونه و كالآتي : حقنت المجموعة الأولى بطفيلي اللشمانيا الأحشائيه الحيه بينما حقنت المجموعةالثانية بلقاح عالق اللشمانيا الجلديه المقتولة بالحرارة . اظهرت المجموعه الثانيه اعلى معدل في تفاعل فرط الحساسية المتأخر(1.5 ±0.23ملم) , واقل المعدلات في كل من معامل الطحال (2.02±0.15) , طول الط
... Show MoreInvestigating the thermal and electrical gains and efficiencies influence the designed photovoltaic thermal hybrid collector (PVT) under different weather conditions. The designed system was manufactured by attaching a fabricated cooling system made of serpentine tubes to a single PV panel and connecting it to an automatic controlling system for measuring, monitoring, and simultaneously collecting the required data. A removable glass cover had been used to study the effects of glazed and unglazed PVT panel situations. The research was conducted in February (winter) and July (summer), and March for daily solar radiation effects on efficiencies. The results indicated that electrical and thermal gains increased by the incre
... Show More