Nanostructure of chromium oxide (Cr2O3-NPs) with rhombohedral structure were successfully prepared by spray pyrolysis technique using Aqueous solution of Chromium (III) chloride CrCl3 as solution. The films were deposited on glass substrates heated to 450°C using X-ray diffraction (XRD) shows the nature of polycrystalline samples. The calculated lattice constant value for the grown Cr2O3 nanostructures is a = b = 4.959 Å & c = 13.594 Å and the average crystallize size (46.3-55.6) nm calculated from diffraction peaks, Spectral analysis revealed FTIR peak characteristic vibrations of Cr-O Extended and Two sharp peaks present at 630 and 578 cm-1 attributed to Cr-O “stretching modes”, are clear evidence of the presence of crystalline Cr2O3. The energy band gap (3.4 eV) for the chromium oxide nanostructures was measured using the UV-VIS-NIR Optical Spectrophotometer. It was found that by scanning electron microscopy (SEM) and image results, there is a large amount of nanostructure with an average crystal size of 46.3-55.6 nm, which indicates that our synthesis process is a successful method for preparing Cr2O3 nanoparticles.
يعد هذا النص أحد النصوص المسمارية المصادرة التي بحوزة المتحف العراقي، ويحمل الرقم المتحفي (235869)، قياساته )12،7x 6x 2،5سم). يتضمن مدخولات كميات من الشعير،أرخ النص الى عصر أور الثالثة (2012-2004 ق.م) و يعود الى السنة الثالثة من حكم الملك أبي-سين (2028-2004 ق.م)،أن الشخصية الرئيسة في هذا النص هو)با-اَ-كا مسمن الماشية( من مدينة أري-ساكرك، ومقارنته مع النصوص المسمارية المنشورة التي تعود الى أرشيفه يبلغ عددها (196) نصاً تضمنت نشاطاته م
... Show MoreA high-performance liquid chromatography method was employed for the quantitative determination of ascorbic acid (AA) which called vitamin C in three types of Iraqi citrus (orange mandarin and aurantium ) and to establish this goal , evaluation of ascorbic acid degradation is so important due to its significant criticality when exposure to ordinary atmospheric conditions. The chromatographic analysis of AA was carried out after their sequential elution with KH2PO4 ( as mobile phase) by reverse-phase HPLC technique with C8 column and UV detection at 214 nm. .Bad resolutions was appeared clearly for C8 column , so another alternative condition were carried out to improve the resolution by replacement of C8 by C18 column .Statistical treat
... Show MoreAn innovative desalination method called electrosorption or capacitive deionization (CDI) has significant benefits for wastewater treatment. This process is performed by using a carbon fiber electrode as a working electrode to remove hexavalent chromium ions from an aqueous solution. The pH, NaCl concentration, and cell voltage were optimized using the Box-Behnken experimental design (BDD) in response surface methodology (RSM) to study the effects and interactions of selected variables. To attain the relationship between the process variables and chromium removal, the experimental data were subjected to an analysis of variance and fitted with a quadratic model. The optimum conditions to remove Cr(VI) ions were: pH of 2, a cell voltage of 4.
... Show MoreRemoval of heavy metals from waste water has received a great deal of attention. The compare Cr
(VI) adsorption characteristics removing from wastewater by using thermally modified and non-modified
eggshells were examined
It is known that the oral administration of ibuprofen caused an irritation of stomach as a side effect due to its carboxylic moiety. Ibuprofen ester was synthesized by linking the carboxylic moiety of ibuprofen and the hydroxylic group of paracetamol to reduce its side effect. Study the kinetic hydrolysis of prepared ester was examined at different values of physiological pH (1.0, 5.8, 6.4 and 7.4) at 37 ± 0.1 of 1 hour period. Measurements of absorbance were carried out by UV-Visible spectrophotometer to follow the stability of ester, it showed Pseudo first order hydrolysis. The pH- apparent rate profiles of ester was exhibited a good stability at pH 1.0 and pH 5.8. Pharmacological activity in vivo of prepared ester was evaluated in re
... Show More