Preferred Language
Articles
/
ijp-60
Effect of gas flow rate on plasma temperature and electron density of atmospheric argon plasma jet
...Show More Authors

In this study, method for experimentally determining the electron density (ne) and the electron temperature (Te) in the atmospheric Argon plasma jet is used; it is based on optical emission spectroscopy (OES). Boltzmann plot method used to calculate these parameters measured for different values of gas flow rate. The results show that the electron temperature decreasing with the increase of gas flow rate also indicates an increasing in the electron density of plasma jet with increasing of gas flow rate.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Mar 15 2018
Journal Name
Journal Of Baghdad College Of Dentistry
The Effect of Addition of Combination of Plasma Treated Polyester and Polyamide Fibers on Surface Roughness and Some Mechanical Properties of Heat Cured Acrylic Resin
...Show More Authors

Background: Poly (methyl methacrylate) has several disadvantages (poor mechanical properties) like impact and transverse strength. In order to overcome these disadvantages, several methods were used to strengthen the acrylic resin by using different fibers or fillers. This study was conducted to evaluate the effect of Plasma treatment of the fiber on mechanical properties Poly (methyl methacrylate) denture base material. Materials and methods: Specimens were prepared from poly methyl metha acrylic (PMMA) divided according to present of fiber into 4 groups (first group without fiber as control group, second group with Plasma treated polyester fibers, third group with Plasma treated polyamide fibers and fourth group Plasma treated combination

... Show More
View Publication
Crossref (2)
Crossref
Publication Date
Mon Oct 01 2012
Journal Name
Iraqi Journal Of Physics
Double probe for measuring the plasma parameters
...Show More Authors

In this work the diode planer magnetron sputtering device was
designed and fabricated. This device consists of two aluminum discs
(8cm) diameter and (5mm) thick. The distance between the two
electrodes is 2cm, 3cm, 4cm and 5cm.
Design and construction a double probe of tungsten wire with
(0.1mm) diameter and (1.2mm) length has been done to investigate
electron temperature, electron and ion density under different
distances between cathode and anode. The probes were situated in
the center of plasma between anode and cathode.
The results of this work show that, when the distance between
cathode and anode increased, the electron temperature decreased.
Also, the electron density increases with the increasing

... Show More
View Publication Preview PDF
Publication Date
Sat Jan 01 2022
Journal Name
3rd International Scientific Conference Of Alkafeel University (iscku 2021)
Simulation and investigation of the ICP plasma torch’s electrical and thermal properties
...Show More Authors

View Publication
Scopus Crossref
Publication Date
Sun Mar 15 2020
Journal Name
Journal Of Baghdad College Of Dentistry
The impact of dental environment stress on caries experience, salivary flow rate and uric acid
...Show More Authors

Background: Several pathologies of the oral cavity have been associated with stress. Dental students need to gain assorted proficiencies as theoretical knowledge, clinical proficiencies, and interpersonal dexterity which is accompanied with high level of stress. Uric acid is the major antioxidant in saliva. The aim of this study is to assess the dental caries experience among dental students with different levels of dental environment stress in relation to physicochemical characteristics of whole unstimulated saliva.

Materials and Methods: the total sample is composed of 300 dental students (73 males, 227 female) aged 22-23 years old, from collage of dentistry / university of Baghdad, from the 4t

... Show More
View Publication Preview PDF
Scopus (6)
Crossref (1)
Scopus Crossref
Publication Date
Wed Jan 01 2020
Journal Name
Journal Of International Society Of Preventive And Community Dentistry
The impact of dental environment stress on dentition status, salivary nitric oxide and flow rate
...Show More Authors

View Publication
Scopus (12)
Crossref (9)
Scopus Clarivate Crossref
Publication Date
Fri Jan 01 2016
Journal Name
Al-mustansiriyah Journal Of Science
Calculate optical parameters of ions beam from plasma source
...Show More Authors

Preview PDF
Publication Date
Sat Aug 31 2019
Journal Name
Iraqi Journal Of Physics
Spectroscopic Diagnostic of Cadmium Sulfide Plasma Produced By LIBS
...Show More Authors

Abstract

       The current study was carried out to reveal the plasma parameters such as ,the electron temperature ( ), electron density (ne) , plasma frequency (fp), Debye length ( ) , Debye number (   for  CdS to employ the LIBS for the purpose of analyzing and determining spectral emission lines using . The results of electron temperature for CdS range (0.746-0.856) eV , the electron density(3.909-4.691)×1018 cm-3. Finally ,we discuss plasma parameters of CdS  through  nano second  laser generated plasma .

View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sun Oct 01 2017
Journal Name
Journal Of The Faculty Of Medicine Baghdad
Measuring of Plasma Melatonin Level in Patients with Preeclampsia
...Show More Authors

Background: disturbed physiological rhythm of blood pressure in preeclampsia is a common finding. The role of oxidative stress in pathogenesis of preeclampsia is well accepted. Melatonin is a powerful free radical scavenger so it's rapidly consumed by enhanced reactive oxygen species in preeclampsia causing non-dipping in blood pressure.Objective: To evaluate the change in plasma melatonin levels in patients with preeclampsia and its relationship with blood pressure.Patients and methods: In this prospective case control study a total of 40 primigravidae pregnant women were recruited during the period of 11 months between August 2015 and August 2016 in Baghdad teaching hospital, medical city, Iraq, divided into two groups:First group

... Show More
View Publication
Crossref (1)
Crossref
Publication Date
Fri Mar 01 2019
Journal Name
Iraqi Journal Of Physics
Influence of working pressure and lasing energy of Al plasma in laser-induced breakdown spectroscopy
...Show More Authors

Aluminum plasma was generated by the irradiation of the target
with Nd: YAG laser operated at a wavelength of 1064 nm. The
effect of laser power density and the working pressure on spectral
lines generating by laser ablation, were detected by using optical
spectroscopy. The electron density was measured using the Stark
broadening of aluminum lines and the electron temperature by
Boltzmann plot method it is one of the methods that are used. The
electron temperature Te, electron density ne, plasma frequency
and Debye length increased with increasing the laser peak
power. The electron temperature decrease with increasing gas
pressure.

View Publication Preview PDF
Crossref
Publication Date
Thu Sep 25 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Effect of poly propylene fibers incorporation and their oxygen plasma treatment on tensile strength, wettability and wear resistance of heat cure denture base acrylic resin
...Show More Authors

Background: Recently, Poly propylene fibers with and without plasma treatment have been used to reinforce heat cure denture base acrylic but, so far some of properties like tensile strength , wettability and wear resistance not evaluated yet, the aim of the study is to clarify the influence of incorporation of treated and untreated fibers on these properties. Materials and methods: Twenty one specimens were fabricated for every tested property(tensile strength, wear resistance and wettability) that classified into three groups(control, untreated poly propylene fibers reinforced specimens and Oxygen plasma treated group)and for each test sevens amples were used(n=7). Tensile strength was tested using Instron universal testing machine, wear

... Show More
View Publication Preview PDF