Preferred Language
Articles
/
ijp-56
Enhancement the sensitivity of humidity sensor based on an agarose infiltration reflection-type photonic crystal fiber interferometer
...Show More Authors

Photonic Crystal Fiber Interferometers (PCFIs) are widely used for sensing applications. This work presents the fabrication and study the characterization of a relative humidity sensor based on a polymer-infiltrated photonic crystal fiber that operates in a Mach- Zehnder Interferometer (MZI) reflection mode. The fabrication of the sensor only involves splicing and cleaving Photonic Crystal Fiber (PCF) with Single Mode Fiber (SMF). A stub of (LMA-10) PCF spliced to SMF (Corning-28). In the splice regions. The PCFI sensor operation based on the adsorption and desorption of water vapour at the silica-air interface within the PCF. The sensor shows a high sensitivity to RH variations from (27% RH - 95% RH), with a change in its reflected power and the position of the interference peaks is found to be shifted that the interference pattern with a 100 nm span can be observed with high humidity sensitivity of (8.49 pm / %RH) is achieved with compact (4mm) PCF length . The sensor has the advantages for suitable for monitoring humidity in microenvironments. The repeatability, long-term stability, measurement accuracy. Wide humidity range. The response time of the sensor is found to be 1.4 sec for a change in RH of 50 %RH. The fast response time suggests that the sensor can potentially be used as a human breath rate monitor in a clinical situation.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Oct 01 2012
Journal Name
Iraqi Journal Of Medical Sciences
Lower Gastrointestinal Bleeding: An Etiological Study.
...Show More Authors

Publication Date
Sun Sep 04 2011
Journal Name
Baghdad Science Journal
An Embedded Data Using Slantlet Transform
...Show More Authors

Data hiding is the process of encoding extra information in an image by making small modification to its pixels. To be practical, the hidden data must be perceptually invisible yet robust to common signal processing operations. This paper introduces a scheme for hiding a signature image that could be as much as 25% of the host image data and hence could be used both in digital watermarking as well as image/data hiding. The proposed algorithm uses orthogonal discrete wavelet transforms with two zero moments and with improved time localization called discrete slantlet transform for both host and signature image. A scaling factor ? in frequency domain control the quality of the watermarked images. Experimental results of signature image

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Jan 02 2017
Journal Name
Al-academy
Aesthetics Environmental Art (An analytical study)
...Show More Authors

Find cares studying the aesthetics of environmental art, one of the topics that is one of the problems of the aesthetic side in the arts of postmodernism, so this research came as an attempt to get to know the aesthetic concepts of environmental art that can be learned from functional testing in the formation of the post-modern control. The research involved four chapters: The first chapter discusses the general framework of the research methodology, as it was displayed in itThe research problem and its importance and define its objective to identify the aesthetics of environmental art at the level of the body, meaning, the receiver .ozlk in Iraq and America as the spatial limits of the time limits are period stretching from 1970 to 2006

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Nov 01 2014
Journal Name
I-manager's Journal On Information Technology
AN ENHANCED METHOD FOR SPRITE EXTRACTING
...Show More Authors

The extracting of personal sprite from the whole image faced many problems in separating the sprite edge from the unneeded parts, some image software try to automate this process, but usually they couldn't find the edge or have false result. In this paper, the authors have made an enhancement on the use of Canny edge detection to locate the sprite from the whole image by adding some enhancement steps by using MATLAB. Moreover, remove all the non-relevant information from the image by selecting only the sprite and place it in a transparent background. The results of comparing the Canny edge detection with the proposed method shows improvement in the edge detection.

Publication Date
Wed May 29 2019
Journal Name
Selected Topics In Facial Nerve Disorders
Introductory Chapter: Facial Nerve - An Overview
...Show More Authors

View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Tue Oct 01 2019
Journal Name
Journal Of Economics And Administrative Sciences
Debt swaps An Islamic Economic Evaluation
...Show More Authors

Introduction:

        Many business owners suffer major financial problems during periods of financial stagnation, the decline of markets and businesses, or under the impact of financial shocks for certain reasons that result in large debts and the consequent financial and legal obligations. This is the beginning of a long and endless path of suffering and the search for a safe exit. It is even worse for financial institutions to facilitate financial solutions that rely on lending as a solution to their financial problem. Debt and its consequences increase, and the problem deepens and becomes complicated until things become entangled and the escape or declaration of bank

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Nov 26 2010
Journal Name
Wireless Personal Communications
Security Problems in an RFID System
...Show More Authors

View Publication
Scopus (24)
Crossref (22)
Scopus Clarivate Crossref
Publication Date
Thu Jun 30 2011
Journal Name
Al-kindy College Medical Journal
Large Epigastric Hernia: an Unusual Presentation
...Show More Authors

We presented here a 65years old lady with an unusual presentation of a large epigastric hernia of twenty years duration .The swelling was occupying all the right hypochondrial region .The diagnosis was made on r^E^a-operative identification of the defect in the linea alba which wassutured after removal of the hernial sac and its contents .The postoperative course was uneventful and the patient remained with no complications or recurrence for more than two years follow up.

View Publication Preview PDF
Publication Date
Tue Feb 01 2022
Journal Name
Academy Of Accounting And Financial Studies Journal
THE ROLE OF THE TARGET COST SYSTEM IN ACTIVATING ENVIRONMENTAL COST MANAGEMENT AN APPLIED STUDY AT ASHOUR GENERAL CONSTRUCTIVE CONTRACT CO
...Show More Authors

The problem of the study was to identify the possibility of benefiting from the application of the target cost system as a modern cost system to activate the environmental cost management instead of the traditional systems used in the company due to the great transformations witnessed by the business environment in all fields, which have resulted in the search for modern systems to provide more accurate and more appropriate information to reduce Costs, because accurate information makes the company have a complete vision to achieve the company’s goals. To solve this problem, the research was based on the following hypothesis (that the role of the target cost system leads to the activation of environmental cost management). Target c

... Show More
Preview PDF
Publication Date
Mon Feb 15 2021
Journal Name
Systematic Review In Pharmacy
Colorimetric Determination Of Sitagliptin As An Oxidation Derivative Of Ninhydrin
...Show More Authors

A sensitive and accurate colorimetric method was developed for the determination of the Sitagliptin phosphate monohydrate, here and after will be named Sitagliptin, in its pure and pharmaceutical form. The suggested approach is based on boosting the sensitivity of the traditional spectrometric methods by derivatizing Sitagliptin into a colored product that absorbs the visible spectrum at 573 nm. The proposed method has effectively improved the sensitivity and the limit of detection for the analysis of Sitagliptin. A linear calibration curve was obtained over the concentration range of 0.1-10 μg/ml with a correlation coefficient of 0.9983. The calculated recovery was within the range of 98.98–100.11%. While the limit of detection LOD and

... Show More
Preview PDF