Preferred Language
Articles
/
ijp-53
Gas sensitivity properties of TiO2/Ag nanocomposite films prepared by pulse laser deposition
...Show More Authors

In this study, a double frequency Q-switching Nd:YAG laser beam (1064 nm and λ= 532 nm, repetition rate 6 Hz and the pulse duration 10ns) have been used, to deposit TiO2 pure and nanocomposites thin films with noble metal (Ag) at various concentration ratios of (0, 10, 20, 30, 40 and 50 wt.%) on glass and p-Si wafer (111) substrates using Pulse Laser Deposition (PLD) technique. Many growth parameters have been considered to specify the optimum condition, namely substrate temperature (300˚C), oxygen pressure (2.8×10-4 mbar), laser energy (700) mJ and the number of laser shots was 400 pulses with thickness of about 170 nm. The surface morphology of the thin films has been studied by using atomic force microscopes (AFM). The Root Mean Square (RMS) value of thin films surface roughness increased with increasing of Ag contents, while the crystallite size was found to decrease with increase in different silver content. The sensitivity toward NO2 and NH3 gas has been measured under different ppm concentrations. TiO2 with noble metal has a sensitivity higher than pure TiO2 where as TiO2 with Ag metal deposited on glass substrate has maximum sensitivity to NO2 gas with a value of ~(50 %) at the nanocomposite 90%TiO2/10%Ag films with best operation temperature at 200 °C. In addition, noble metal like Ag to the titanium dioxide materials makes them sensitive to NO2 gas.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Dec 20 2021
Journal Name
Baghdad Science Journal
Design of L-Band Multiwavelength Laser for TDM/WDM PON Application
...Show More Authors

This paper presents on the design of L-Band Multiwavelength laser for Hybrid Time Division Multiplexing/ Wavelength Division Multiplexing (TDM/WDM) Passive Optical Network (PON) application. In this design, an L-band Mulltiwavelength Laser is designed as the downstream signals for TDM/WDM PON. The downstream signals ranging from 1569.865 nm to 1581.973 nm with 100GHz spacing. The multiwavelength laser is designed using OptiSystem software and it is integrated into a TDM/WDM PON that is also designed using OptiSystem simulation software. By adapting multiwavelength fiber laser into a TDM/WDM network, a simple and low-cost downstream signal is proposed. From the simulation design, it is found that the proposed design is suitable to be used

... Show More
View Publication Preview PDF
Scopus (3)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Fri Aug 20 2021
Journal Name
Iraqi Journal Of Laser
Pulsed Er,Cr:YSGG Laser For Surface Modification of Dental Zerconia Ceramic
...Show More Authors

Background: Surface treatment of machined dental zirconia for enhancement of the adhesion to resin cement, using Er,Cr:YSGG  Laser. Materials and Methods: Total number of 42 zirconia disc specimens (9 mm diameter, and 2 mm height) was sintered according to the manufacturer instruction. They are divided into six groups, each group of seven samples. Laser groups (Experiment parameters) were depend on laser total irradiation time, pulse duration, and power. Group (A): 20 sec., 60 µs pulse duration. Group (B): 30 sec., 60 µs pulse duration. Group (C): 40 sec., 60 µs pulse duration. Group (D): 20 sec., 700 µs pulse duration. Group (E): 30 sec., 700 µs pulse duration, with different powers used (1, 1

... Show More
View Publication Preview PDF
Publication Date
Wed Dec 15 2010
Journal Name
Iraqi Journal Of Laser
Detection and Quantification of Class I Caries with Laser Fluorescence Technique
...Show More Authors

The objective of the present study is to verify the actual carious lesion depth by laser
fluorescence technique using 650 nm CW diode laser in comparison with the histopathological
investigation. Five permanent molar teeth were extracted from adult individuals for different reasons
(tooth impaction, periodontal diseases, and pulp infections); their ages were ranging from 20-25 years
old. Different carious teeth with varying clinical stages of caries progression were examined. An
experimental laser fluorescence set-up was built to perform the work regarding in vitro detection and
quantification of occlusal dental caries and the determination of its actual clinical carious lesion depth by
650 nm CW diode laser (excitat

... Show More
View Publication Preview PDF
Publication Date
Fri Feb 08 2019
Journal Name
Iraqi Journal Of Laser
Spot Welding of Dissimilar Metals Using an Automated Nd:YAG Laser System
...Show More Authors

An assembled pulsed Nd:YAG laser-robot system for spot welding similar and dissimilar metals is presented in this paper. The study evaluates the performance of this system through investigating the possibility and accuracy of executing laser spot welding of 0.2 mm in thickness stainless steel grade AISI302 to 0.5 mm in thickness low carbon steel grade AISI1008. The influence of laser beam parameters (peak power, pulse energy, pulse duration, repetition rate, and focal plane position on the final gained best results are evaluated. Enhancement of the experimental results was carried by a computational simulation using ANSYS FLUENT 6.3 package code.

View Publication Preview PDF
Publication Date
Thu Jan 23 2020
Journal Name
Iraqi Journal Of Laser
Fractional CO2 Laser Treatment of Mild Periorbital Wrinkles in Iraqi Patients
...Show More Authors

Background and Objective: Public demand for procedures to rejuvenate photodamaged facial skin have stimulated the use of fractional CO2 laser as a precise and predictable treatment modality. The purpose of this study was to assess the effect of fractional CO2 laser system for reducing periorbital rhytids.

Materials and Methods: twenty seven subjects with mild periocular wrinkles, and photoaged skin of the face were prospectively treated two to three times (according to clinical response) in the periorbital area with a fractional CO2 laser device equipped with a scanning hand piece. Improvements in eyelid wrinkles was evaluated clinically and photographically. Subjects also scored satisfaction and

... Show More
View Publication Preview PDF
Publication Date
Fri Jun 18 2004
Journal Name
Iraqi Journal Of Laser
Design and Construction of Semiconductor Laser Range Finder for Target Designation
...Show More Authors

The aim of this research is to design and construct a semiconductor laser range finder
operating in the near infrared range for ranging and designation. The main part of the range finder is the
transmitter which is a semiconductor laser type GaAs of 0.904 mm wavelength with a beam expander,
and the receiver with its collecting optics. The characteristics of transmitter pulse width were 200ns and
threshold current 10 Amp. and maximum operating current 38 Amp. The repetition rate was set at 660 Hz
and maximum output power about 1 watt. The divergence of the beam was 0.268o. A special computer
code was used for optimum optical design and laser spot size analysis and for calculation of atmosphere
attenuation.

View Publication Preview PDF
Publication Date
Tue Jun 12 2007
Journal Name
Iraqi Journal Of Laser
Generation of 629 nm Pulsed Laser Using an Optical Parametric Amplifier
...Show More Authors

The main purpose of this work is the construction of an optical parametric amplifier (OPA) to generate a 629 nm pulsed laser. KTP nonlinear crystals were used for both parametric oscillation and amplification. A singly resonant parametric oscillator (OPO) is constructed to generate a signal of 1.54 μm and idler of 3.4 μm when the OPO system is pumped by 1.064 μm Q – switched Nd: YAG laser. The signal was then mixed with the pumping beam in OPA system to form the wanted wavelength. The obtained optical conversion efficiency was 60%.

View Publication Preview PDF
Publication Date
Thu Feb 07 2019
Journal Name
Iraqi Journal Of Laser
Treatment of Skin Scar Using CO2 Laser with or Without Corticosteroid
...Show More Authors

CO2 Laser (10600nm) is the recent method in the management of challenging skin scar resulting from trauma, burn and surgical wound. The aim of this study was to evaluate the efficacy & safety of fractional CO2 laser (10600nm) in treatment of skin scar. Materials and Methods:Twenty patients with different types of scars treated with fractional CO2 (10600nm) laser, (10 patients) were given additional intralesional Triamcinolone. Results: All of the twenty patients included in this study showed some sort of improvements in scar texture, height and pliability and all of the ten patients who received intralesional Triamcinolone after laser show complete satisfaction. Conclusion:Fractional CO2 (10600nm) laser can be used as alternative, ef

... Show More
View Publication Preview PDF
Publication Date
Tue Sep 01 2009
Journal Name
Journal Of Nonlinear Optical Physics & Materials
SPECTRAL WIDTH VARIATION OF ULTRASHORT LASER PULSES IN MONOMODE OPTICAL FIBERS
...Show More Authors

Femtosecond laser pulse propagation in monomode optical fibers is demonstrated and investigated numerically (by simulations) and experimentally in this paper. A passively mode locked Nd:glass laser giving a pulse duration of about 200 fsec at 1053 nm wavelength and 120 mW average optical power with 100 MHz repetition rate is used in the experimental work. Numerical simulations are done by solving the nonlinear Schrödinger equation with the aid of Matlab program. The results show that self phase modulation (SPM) leads to compression of the spectral width from 5 nm to 2.1 nm after propagation of different optical powers (34, 43, 86 and 120 mW) in fibers of different length (5, 15, 35 m). The varying optical powers produced a varying

... Show More
View Publication
Scopus (1)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Sat Feb 09 2019
Journal Name
Iraqi Journal Of Laser
Reconstruction of 3D Shape for an Object using Laser Scanning Triangulation
...Show More Authors

This paper presents a method of designing and constructing a system capable of acquiring
the third dimension and reconstructs a 3D shape for an object from multi images of that object using
the principle of active optical triangulation. The system consists of an illumination source, a photo
detector, a movement mechanism and a PC, which is working as a controlling unit for the hard ware
components and as an image processing unit for the object multi view raw images which must be
processed to extract the third dimension. The result showed that the optical triangulation method
provides a rapid mean for obtaining accurate and quantitative distance measurements. The final
result's analysis refers to the necessity of usin

... Show More
View Publication Preview PDF