Frustrated Total Internal Reflection FTIR phenomenon is manifested employing Newton‟s rings setup generated via a coherent light beam of a laser diode ( . All concentric bright and dark rings, except the central bright spot, were noticed to recede (disappear) when the incident angle exceeded the critical angle of 41o.
It was also shown that the current setup has proven its applicability for other tests and can give convenient results that conform with theory. Neither the concept nor the design is beyond what can be realized in an undergraduate laboratory. However, technical improvements in mounting the prism - lens may be advisable. As an extension of the experiments, the effect can be studied using hollow prism filled with liquids of different refractive indices for both S and P polarizations of light. Also, the relationship of wavelength on the penetration depth can be explored.
The support qualitative information regards as an additional step in the process of decision-making where the method following by companies to provide information help in the creation of value because it is very important to deliver information to investors about their stratigies and what happen truly inside the companies i.e. every case relating with the expectations of stockhotslder and the prices of markets depending on those expectation ,and if the matter isn’t that there will be lack of confidence thate couldn’t be backed again. The decisions of the investors effected by security ,economic ,political, psychological, emotional ,and financial factors .
... Show MoreSemi-empirical methods were applied for calculating the vibration frequencies and IR absorption intensities for normal coordinates of the {mono (C56H28), di (C84H28), tri (C112H28) and tetra (C140H28)} -rings layer for (7,7) armchair single wall carbon nanotube at their equilibrium geometries which were all found to have D7d symmetry point group.
Assignment of the modes of vibration (3N-6) was done depending on the pictures of their modes by applying (Gaussian 03) program. Comparison of the vibration frequencies of (mono, di, tri and tetra) rings layer which are active in IR, and inactive in Ramman spectra. For C-H stretching vibrat
... Show Moreتشغل الفضاءات الداخلية الطبية اهتمام واسع , لما توفره من رعاية صحية للمرضى ,فلابد ان يُهتَمْ بها من الجانب الوظيفي(الادائي), لتحقيق الراحة البصرية والنفسية والجسدية لغرض الوصول الى الاداء الجيد للكادر الطبي, ولهذا وجد ضرورة التعرف على تلك الفضاءات الداخلية بشكل اعمق , وهل انها ملاءمة للمرتكزات التصميمية المتعارف عليها؟ , لذلك تم تسليط الضوء على الفضاءات الداخلية للمختبرات الطبية, وقد تناول البحث المشكلة واه
... Show MoreThis study aims to show, the strength of steel beam-concrete slab system without using shear connectors (known as a non-composite action), where the effect of the friction force between the concrete slab and the steel beam has been investigated, by using finite element simulation.
The proposed finite element model has been verified based on comparison with an experimental work. Then, the model was adopted to study the system strength with a different steel beam and concrete slab profile. ABAQUS has been adopted in the preparation of all numerical models for this study.
After validation of the numerical models, a parametric study was conducted, with linear and non-linear Regression analysis. An equation re
... Show MoreBack ground: Chronic total occlusion (CTO) of coronary arteries remains one of the most challenging lesion subsets in interventional cardiology even with the development of medical devices and operator expertise. Successful revascularization results in improved in angina status ,increased exercise capacity and reduces the need for lat CABG surgery .
Objectives: This study sought to determine the overall procedural success rate of percutaneous coronary intervention (PCI) for CTOs and to examine the relation between variables such as; patients’ characteristics, risk factors, lesion characteristics and procedural success rate.
Methods: In this study ,clinical and coronary angiography data of (80) patients with CTO who underwent PCI
Abstract: Polarization beam splitter (PBS) integrated waveguides are the key components in the receiver of quantum key distribution (QKD) systems. Their function is to analyze the polarization of polarized light and separate the transverse-electric (TE) and transverse-magnetic (TM) polarizations into different waveguides. In this paper, a performance study of polarization beam splitters based on horizontal slot waveguide has been investigated for a wavelength of . PBS based on horizontal slot waveguide structure shows a polarization extinction ratio for quasi-TE and quasi-TM modes larger than with insertion loss below and a bandwidth of . Also, the fabrication tolerance of the structure is analyzed.<
... Show MoreIn this research, analytical study for simulating a Fabry-Perot bistable etalon (F-P cavity) filled with a dispersive optimized nonlinear optical material (Kerr type) such as semiconductors Indium Antimonide (InSb). An optimization procedure using reflective (~85%) InSb etalon (~50µm) thick is described. For this etalon with a (50 µm) spot diameter beam, the minimum switching power is (~0.078 mW) and switching time is (~150 ns), leading to a switching energy of (~11.77 pJ) for this device. Also, the main role played by the temperature to change the etalon characteristic from nonlinear to linear dynamics.
Examining of 80 feces samples showed that 31 samples of the house and stray cats harbored either single or mixed infection with eight species of parasites and protozoa with a total infection rate 38.75 %.The results on parasite classes are: Toxocara cati (5%), Ancylostoma tubeforme (3.75%), Capillaria felis(3.75%), Isospora sp.(10%), Cryptosporidium parvum(3.75%), Cryptosporidium muris (6.25%), Toxoplasma gondi (3.75%), Giardia sp.(2.5%) infection from feces of cats that showed single, double and triple infections. Our findings revealed the risk for public health, thus preventive measures should be implemented.