Preferred Language
Articles
/
ijp-483
Estimating sugar concentration in human blood serum using Surface Plasmon Resonance (SPR) –based optical fiber sensor
...Show More Authors

Surface Plasmon Resonance (SPR)-based plastic optical fiber sensor for estimating the concentration and refractive index of sugar in human blood serum. The sensor is fabricated by a small part (10mm) of optical fiber in the middle is embedded in a resin block and then the polishing process is done, after that it is deposited with about (40nm) thickness of gold metal. The blood serum is placed on gold coated core of an Optical grade plastic optical fiber of 980 µm core diameter.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Jun 01 2014
Journal Name
Baghdad Science Journal
Preparation of polymer thin film using as NH3 gas Sensor
...Show More Authors

Polyaniline organic Semiconductor polymer thin films have been prepared by oxidative polymerization at room temperature, this polymer was deposited on glass substrate with thickness 900nm, FTIR spectra was tested , the structural,optical and electrical properties were studied through XRD ,UV-Vis ,IR measurements ,the results was appeared that polymer thin film sensing to NH3 gas.

View Publication Preview PDF
Crossref
Publication Date
Wed Jun 29 2022
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Measuring Dyes Concentration Using a Low-Cost Visible-Light Spectrophotometer
...Show More Authors

   A low-cost, RGB LED-based visible-light spectrophotometer was designed to measure dyes concentration. Dyes are widely used as indicators or coloring agents in different applications and knowing their concentration is an essential part for many studies. The proposed spectrophotometer provides many functionalities that clones the traditional expensive spectrophotometers for a budged price under $50. It was aimed to provide a versatile tool for instructors and educators to teach their students the fundamental concepts behind spectrophotometry. Malachite green, methyl red, and methyl orange dyes were chosen to be good samples to show the integrity of the proposed spectrophotometer in terms of accuracy, repeatability, and sensitivity as

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Wed Sep 14 2016
Journal Name
Journal Of Baghdad College Of Dentistry
Effect of Mouth Rinses on Surface Roughness of Two Methacrylate-Based and Siloraine-Based Composite Resins
...Show More Authors

Background: Various fluids in the oral environment can affect the surface roughness of resin composites. This in vitro study was conducted to determine the influence of the mouth rinses on surface roughness of two methacrylate-based resin (nanofilled and packable composite) and siloraine-based resin composites.

Materials and methods: Disc-shaped specimens (12 mm in diameter and 2mm in height) were prepared from three types of composi

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed May 01 2019
Journal Name
Sensors And Actuators B: Chemical
Fabrication and Characterizations of a Novel Etched-tapered Single Mode Optical Fiber Ammonia Sensors Integrating PANI/GNF Nanocomposite
...Show More Authors

View Publication
Scopus (41)
Crossref (47)
Scopus Clarivate Crossref
Publication Date
Sat Apr 01 2023
Journal Name
The Ocular Surface
Detecting dry eye from ocular surface videos based on deep learning
...Show More Authors

View Publication
Scopus (22)
Crossref (20)
Scopus Clarivate Crossref
Publication Date
Fri Sep 30 2022
Journal Name
Journal Of Economics And Administrative Sciences
Estimation of Reliability through the Wiener Degradation Process Based on the Genetic Algorithm to Estimating Parameters
...Show More Authors

      In this paper, the researcher suggested using the Genetic algorithm method to estimate the parameters of the Wiener degradation process,  where it is based on the Wiener process in order to estimate the reliability of high-efficiency products, due to the difficulty of estimating the reliability of them using traditional techniques that depend only on the failure times of products. Monte Carlo simulation has been applied for the purpose of proving the efficiency of the proposed method in estimating parameters; it was compared with the method of the maximum likelihood estimation. The results were that the Genetic algorithm method is the best based on the AMSE comparison criterion, then the reliab

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Dec 30 2014
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
PREPARATION OF PVC HOLLOW FIBER MEMBRANE USING (DMAC/ACETONE)
...Show More Authors

Membrane manufacturing system was operated using dry/wet phase inversion process. A sample of hollow fiber membrane was prepared using (17% wt PVC) polyvinyl chloride as membrane material and N, N Dimethylacetamide (DMAC) as solvent in the first run and the second run was made using (DMAC/Acetone) of ratio 3.4 w/w. Scanning electron microscope (SEM) was used to predict the structure and dimensions of hollow fiber membranes prepared. The ultrafiltration experiments were performed using soluble polymeric solute poly ethylene glycol (PEG) of molecular weight (20000 Dalton) 800 ppm solution 25 °C temperature and 1 bar pressure. The experimental results show that pure water permeation increased from 25.7 to 32.2 (L/m2.h.bar) by adding a

... Show More
View Publication
Crossref
Publication Date
Tue Dec 30 2014
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
PREPARATION OF PVC HOLLOW FIBER MEMBRANE USING (DMAC/ACETONE)
...Show More Authors

Membrane manufacturing system was operated using dry/wet phase inversion process. A sample of hollow fiber membrane was prepared using (17% wt PVC) polyvinyl chloride as membrane material and N, N Dimethylacetamide (DMAC) as solvent in the first run and the second run was made using (DMAC/Acetone) of ratio 3.4 w/w. Scanning electron microscope (SEM) was used to predict the structure and dimensions of hollow fiber membranes prepared. The ultrafiltration experiments were performed using soluble polymeric solute poly ethylene glycol (PEG) of molecular weight (20000 Dalton) 800 ppm solution 25 °C temperature and 1 bar pressure. The experimental results show that pure water permeation increased from 25.7 to 32.2 (L/m2.h.bar) by adding aceton

... Show More
View Publication Preview PDF
Publication Date
Tue Jul 25 2023
Journal Name
Journal Of Optical Communications
Design mode filtering interferometer using etched double clad fiber
...Show More Authors
Abstract<p>Mode filtering technique is one of the most desired techniques in optical fiber communication systems, especially for multiple input multiple output (MIMO) coherent optical communications that have mode-dependent losses in communication channels. In this work, a special type of optical fiber sensing head was used, where it utilizes DCF13 that is made by Thorlabs and has two numerical apertures (NA’s). One is for core and 1st cladding region, while the 2nd relates the 1st cladding to the 2nd cladding. Etching process using 40 % hydro-fluoric (HF) acid was performed on the DCF13 with variable time in minutes. Investigation of the correlation between the degree of etching and the re</p> ... Show More
View Publication
Scopus (6)
Crossref (5)
Scopus Crossref
Publication Date
Sun Mar 07 2010
Journal Name
Baghdad Science Journal
Measurement of Alpha Emitters Concentration in Tomato Fruits Using CR – 39 Plastic Track Detector
...Show More Authors

Our country suffered from pollution translation as a result to the wars events, so, it is necessary to measure the amount of radiation in the fields that are of indirect contact with human life and health. The main aim of the present work is to measure the concentration of alpha emitters in tomato fruits collected from different farms in Al – Basra governorate in the south of Iraq. Nuclear track detectors of type CR – 39 are used as a detection device and Can technique as a detection technique. Results show that the maximum concentration recorded is sample no.7 of site Al – Rafidhya which was equal to (6.9621 ± 0.111) ppm and sample no.1 of site Lothan with concentration equals to (4.9236 ± 0.117) ppm. The minimum concentratio

... Show More
View Publication Preview PDF
Crossref