Preferred Language
Articles
/
ijp-447
Spectroscopic study the plasma parameters for SnO2 doped ZnO prepared by pulse Nd:YAG laser deposition
...Show More Authors

 In this work, plasma parameters such as (electron temperature (Te), electron density (ne), plasma frequency (fp) and Debye length (λD)) were studied using spectral analysis techniques. The spectrum of the plasma was recorded with different energy values, SnO2 and ZnO anesthetized at a different ratio (X = 0.2, 0.4 and 0.6) were recorded. Spectral study of this mixing in the air. The results showed electron density and electron temperature increase in zinc oxide: tin oxide alloy targets. It was located  that  The intensity of the lines increases in different laser peak powers when the laser peak power increases and then decreases when the force continues to increase.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Oct 03 2025
Journal Name
Al–bahith Al–a'alami
Challenges Faced by the Media under the Fragile State: Analytical Study of the Iraqi Media Reality
...Show More Authors

This study aims at defining the concept of the fragile state, a term that came into existence in 2014, when the states that had internal Problems and external interventions were referred to as the failure states. However, the indicators for their designation and the criteria adopted are 12 indicators that address all aspects of the State’s duties vis-a-vis its citizens. The study examined the reasons that led to the continuation of Iraq within the fragile states, and the selection of the five years within the time limits of the study due to the factors that led to the decline of Iraq and falling back within the most fragile countries. The study dealt with the fragile state challenges to the media reality as a result of the change of it

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Feb 03 2019
Journal Name
Iraqi Journal Of Physics
Influence of non-thermal argon plasma needle on blood coagulation
...Show More Authors

Non-thermal argon plasma needle at atmospheric pressure was
constructed. The experimental setup was based on a simple and low
cost electric component that generates a sufficiently high electric
field at the electrodes to ionize the argon gas which flow at
atmospheric pressure. A high AC power supply was used with 1.1
kV and 19.57 kHz. Non-thermal Argon plasma used on blood
samples to show the ability of non-thermal plasma to promote blood
coagulation. Three tests have been done to show the ability of plasma
to coagulate both normal and anti-coagulant blood. Each blood
sample has been treated for varying time from 20sec. to 180sec. at
different distances. The results of the current study showed that the
co

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Feb 04 2019
Journal Name
Iraqi Journal Of Physics
Diagnostics of low-pressure capacitively coupled RF discharge argon plasma
...Show More Authors

Low-pressure capacitively coupled RF discharge Ar plasma has been studied using Langmuir probe. The electron temperature, electron density and Debay length were calculated under different pressures and electrode gap. In this work the RF Langmuir probe is designed using 4MHz filter as compensation circuit and I-V probe characteristic have been investigated. The pressure varied from 0.07 mbar to 0.1 mbar while electrode gap varied from 2-5 cm. The plasma was generated using power supply at 4MHz frequency with power 300 W. The flowmeter is used to control Argon gas flow in the range of 600 standard cubic centimeters per minute (sccm). The electron temperature drops slowly with pressure and it's gradually decreased when expanding the electro

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sun Feb 10 2019
Journal Name
Iraqi Journal Of Physics
Diagnostics of dusty plasma properties in planar magnetron sputtering device
...Show More Authors

The effect of Al dust particles on glow discharge regions, discharge
voltage, discharge current, plasma potential, floating potential,
electron density and electron temperature in planar magnetron
sputtering device has been studied experimentally. Four cylindrical
Langmuir probes were employed to measure plasma parameters at
different point on the radial axis of plasma column. The results
shows the present of Al dust causes to increase the discharge voltage
and reduce the discharge current. There are two electron groups in
the present and absent of Al dust particles. The radial profiles of
plasma parameters in the present of dust are non- uniform. The
floating potential of probe becomes more negatively while

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Dec 01 2023
Journal Name
Environmental Processes
Removal of Dyes from Aqueous Solutions using Non-Thermal Plasma
...Show More Authors

View Publication
Crossref (4)
Clarivate Crossref
Publication Date
Sun Oct 01 2023
Journal Name
Heliyon
The preventive/therapeutic effect of CO2 laser and MI Paste Plus® on intact and demineralized enamel against Streptococcus mutans (In Vitro Study)
...Show More Authors

View Publication Preview PDF
Scopus (3)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Tue Apr 28 2020
Journal Name
Journal Of Law And Humanities Sciences
Fair compensation for expropriation for the public benefit (A comparative study)
...Show More Authors

The right to property is one of the most fundamental rights enjoyed by individuals, and most national constitutions and laws, as well as international conventions, have to be respected and protected only in accordance with the economic and social development of the country (the so-called public benefit) and in return for just compensation. What is fair compensation?

Publication Date
Tue Nov 01 2022
Journal Name
Journal Of Medicinal And Chemical Sciences
Echocardiographic Assessment of the Aortic Stenosis Valve Area: Parameters and Outcome
...Show More Authors

Background: Among individuals who have a stenotic aortic valve, a precise assessment of aortic valve area is essential for clinical judgment. So far, no studies have been conducted to investigate and assess the role of the three dimensional echo-cardiography in the assessment of the valve stenosis. This study aims to compare and assess the precision of the measurement of the stenosis area of the aortic valve by 2D versus 3D echo-cardiography.

Scopus (10)
Scopus
Publication Date
Fri Nov 15 2024
Journal Name
Iraqi Journal Of Science
Investigating the Correlations between Physical Parameters of Elliptical and Lenticular Galaxies
...Show More Authors

This study aims to investigate the features of stellar-gaseous kinematics and dynamics mass using scaling coefficient relationships (such as the Faber–Jackson relation (FJR)) of two samples of elliptical and lenticular galaxies. These two samples of 80 ellipticals and 97 lenticulars were selected from previous literature works. The Statistical Package for Social Sciences )SPSS( and Matrix Laboratory (MATLAB) program were used to find out the associations of multiple factors under investigation such as main kinematic properties of the gaseous-stellar (effective radius Re, surface density within the effective radius (Ʃeff) , stellar mass in the blue band (Mstar (B)), gas mass ( Mgas), dynamic (Mdyn) and baryonic (Mbar), supermassiv

... Show More
View Publication
Scopus Crossref
Publication Date
Sun Sep 22 2019
Journal Name
Baghdad Science Journal
Spectral Properties of Hybrid of Rhodamine (6G) Dyes Doped Epoxy Resin Dissolved in Chloroform
...Show More Authors

            The research is dealing with the absorption and fluorescence spectra for the hybrid of  an Epoxy Resin doped with organic dye Rhodamine (R6G) of different concentrations (5*10-6, 5*10-5, 1*10-5, 1*10-4, 5*10-4) Mol/ℓ at room temperature. The Quantum efficiency Qfm, the rate of fluorescence emission Kfm (s-1), the non-radiative lifetime τfm (s), fluorescence lifetime τf and the Stokes shift were calculated. Also the energy gap (Eg) for each dye concentration was evaluated. The results showed that the maximum quantum effi

... Show More
View Publication Preview PDF
Scopus (4)
Crossref (1)
Scopus Clarivate Crossref