Preferred Language
Articles
/
ijp-399
Wear rate of epoxy resin reinforced with multi walls carbon nanotubes
...Show More Authors

In this study, nanocomposites have been prepared by adding
multiwall carbon nanotubes (MWCNTs) with weight ratios (0, 2, 3,
4, 5) wt% to epoxy resin. The samples were prepared by hand lay-up
method. Influence of an applied load before and after immersion in
sodium hydroxide (NaOH) of normality (0.3N) for (15 days) at
laboratory temperature on wear rate of Ep/MWCNTs
nanocomposites was studied. The results showed that wear rate
increases with increasing the applied load for the as prepared and
immersed samples and after immersion. It was also found that epoxy
resin reinforced with MWCNTs has wear rate less than neat epoxy.
The sample (Ep + 5wt% of MWCNTs) has lower wear rate. The
immersion effect in base solution led to increase in wear rate values
for all samples compared to natural condition.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Sep 14 2016
Journal Name
Journal Of Baghdad College Of Dentistry
Tooth Wear in Relation to Selected Salivary Variables among a Group of Older Adults
...Show More Authors

Background: Tooth wear is one of the most concerning problems of the current dental practice especially among older subjects. The aim of this study is to determine the severity of tooth wear and its relation with selected salivary variables (salivary pH and vitamin C level) among a group of older adults in Mosul city/Iraq. Materials and methods: All subjects (30 subjects) of both gender tookpart in the current study; sixteen of them were older adults (55-65 years) and compared with fourteen middle-aged adults (30-40 years) at Textile factory in Mosul city/Iraq. Unstimulated salivary samples were collected and salivary pH was immediately measured. Salivary vitamin C level was determined colormetrically. Severity of tooth wear was determined

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue May 04 2021
Journal Name
Journal Of Tribology
Hardened Edges Effects on Wear Characteristics of Cultivator Sweeps Using Circular Soil Bin Test
...Show More Authors
Abstract<p>Tillage tools are subject to friction and low-stress abrasive wear processes with the potential deterioration of the desired soil quality, loss of mechanical weed efficacy, and downtime for replacing worn tools. Limited experimental methods exist to quantify investigate the effect of wear-resistant coatings on shape parameters of soil-engaging tools. ASTM standard sand/rubber wheel abrasion and pin-on-disk tests are not able to simulate wear characteristics of the complex shape of the tillage tools. Even though the tribology of tillage tools can be realistic from field tests, tillage wear tests under field conditions are expensive and often challenging to generate repeatable engineeri</p> ... Show More
View Publication
Scopus (10)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Fri Jul 26 2019
Journal Name
Dental Materials Journal
Semi-interpenetrating network composites reinforced with Kevlar fibers for dental post fabrication
...Show More Authors

View Publication
Scopus (15)
Crossref (11)
Scopus Clarivate Crossref
Publication Date
Tue Feb 12 2019
Journal Name
Iraqi Journal Of Physics
A Study of the generation of laser soliton from spontaneous emission by ring cavity with carbon nanotube
...Show More Authors

We demonstrate a behavior of laser pulse grows through fiber laser inside and output cavity with a soliton fiber laser based on the multi-wall carbon nanotube saturable absorber (SA), we investigate the effects of a saturable absorber parameter on the mode-locking of a realistic Erbium fiber ring laser. Generalized nonlinear Schrodinger equation including the nonlinear effects as gain dispersion, second anomalous group velocity dispersion (GVD), self phase modulation (SPM), and two photon absorption used to describe pulse evolution. An analytical method has been used to understand and to quantify the role of the SA parameter on the propagation dynamics of pulse laser. We compute the chirp, power, width and phase of the soliton for range

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Aug 01 2020
Journal Name
Computational Biology And Chemistry
A graph-based multi-sample test for identifying pathways associated with cancer progression
...Show More Authors

Cancer is in general not a result of an abnormality of a single gene but a consequence of changes in many genes, it is therefore of great importance to understand the roles of different oncogenic and tumor suppressor pathways in tumorigenesis. In recent years, there have been many computational models developed to study the genetic alterations of different pathways in the evolutionary process of cancer. However, most of the methods are knowledge-based enrichment analyses and inflexible to analyze user-defined pathways or gene sets. In this paper, we develop a nonparametric and data-driven approach to testing for the dynamic changes of pathways over the cancer progression. Our method is based on an expansion and refinement of the pathway bei

... Show More
View Publication Preview PDF
Scopus (6)
Crossref (5)
Scopus Clarivate Crossref
Publication Date
Sun Nov 01 2020
Journal Name
2020 2nd Annual International Conference On Information And Sciences (aicis)
An Enhanced Multi-Objective Evolutionary Algorithm with Decomposition for Signed Community Detection Problem
...Show More Authors

View Publication
Scopus (7)
Crossref (2)
Scopus Crossref
Publication Date
Tue May 07 2024
Journal Name
Heliyon
Micro-shear bond strength of a novel resin-modified glass ionomer luting cement (eRMGIC) functionalized with organophosphorus monomer to different dental substrates
...Show More Authors

Objectives: This study aims to assess and compare the micro-shear bond strength (μSBS) of a novel resin-modified glass-ionomer luting cement functionalized with a methacrylate co-monomer containing a phosphoric acid group, 30 wt% 2-(methacryloxy) ethyl phosphate (2-MEP), with different substrates (dentin, enamel, zirconia, and base metal alloy). This assessment is conducted in comparison with conventional resin-modified glass ionomer cement and self-adhesive resin cement. Materials and methods: In this in vitro study, ninety-six specimens were prepared and categorized into four groups: enamel (A), dentin (B), zirconia (C), and base metal alloys (D). Enamel (E) and dentin (D) specimens were obtained from 30 human maxillary first premolars e

... Show More
Preview PDF
Publication Date
Mon Apr 01 2019
Journal Name
Ieee Transactions On Information Forensics And Security
Opportunistic Scheduling for Average Secrecy Rate Enhancement in Fading Downlink Channel With Potential Eavesdroppers
...Show More Authors

View Publication
Scopus (22)
Crossref (20)
Scopus Clarivate Crossref
Publication Date
Fri Jun 30 2023
Journal Name
Diyala Journal Of Medicine
Correlation with renin-angiotensin-aldosterone and glomerular filtration rate in chronic renal failure patients
...Show More Authors

Background: One of the more significant hormonal systems, the renin-angiotensin-aldosterone system, controls the kidney function, adrenal gland through its effect on the balance of sodium and potassium, blood pressure, fluid volume, and also manages the functions of cardiovascular. Objective: To clarify the interrelationship between renal dysfunction and renin-angiotensin-aldosterone system. Patients and Methods: One hundred samples were collected from December 1, 2022, to February 18, 2023, from Al Shams Medical Laboratories (56 male, and 44) female, age range (of 45-60 years), all of them were volunteers suffering from chronic renal failure in the third stage the average glomerular filtration rate was 35. 70 ± 0.37 12

... Show More
View Publication Preview PDF
Scopus (2)
Scopus Crossref
Publication Date
Sat Dec 01 2018
Journal Name
Agricultural Engineering
Evaluation of Flat Fan Nozzles Operating Parameters Under Conditions of Accelerated Boundary and Destructive Wear
...Show More Authors
Abstract<p>Two tests were carried out to measure the standard flat fan nozzles wear during a specific period of an accelerated wear procedure. The first test aimed at getting 10% increase in the flow rate compared to the nominal flow rate, which is the threshold to replace the nozzles according to the nozzles testing standards. The second test was to wear the nozzles intensively (100 hours of accelerated wear), which represents the use of nozzles beyond the allowed threshold. The results showed that the flow rate reached 1.31 l·min<sup>−1</sup> (equal to 10% increase) for the tested nozzles after 35 hours of the wear test. For the second test, the 10% increase of the flow rate was r</p> ... Show More
Crossref (1)
Crossref