The effect of α-particle irradiation on the optical absorption in nuclear track detectors (LR115) has been studied. These detectors have been irradiated with different doses. The optical absorption has been measured using the ultraviolet-visible (UV-1100) spectroscopy, that irradiation results in shifting the peaks of the optical absorption. The values of Urbach energy have been calculated from the position of steady-state optical band gap energy, for a standard sample which was unirradiated with indirect influence, has been found 1.9 eV whereas its value after irradiation 1.98 eV. In case of the direct influence, it is found to be, respectively, before irradiation 1.98 eV and after irradiation 2.05 eV. From these results, we can reveal that the values of energy gaps in direct–coincidence before and after irradiation greater than those for indirect one. The number of carbon atoms has been determined in each case for the optical energy gaps.
The main role of infill drilling is either adding incremental reserves to the already existing one by intersecting newly undrained (virgin) regions or accelerating the production from currently depleted areas. Accelerating reserves from increasing drainage in tight formations can be beneficial considering the time value of money and the cost of additional wells. However, the maximum benefit can be realized when infill wells produce mostly incremental recoveries (recoveries from virgin formations). Therefore, the prediction of incremental and accelerated recovery is crucial in field development planning as it helps in the optimization of infill wells with the assurance of long-term economic sustainabi
Numerical investigation has been carried out on heat transfer and friction factor characteristics of copper-water nanofluid flow in a constant heat-fluxed tube with the existence of new configuration of vortex generator using Computational Fluid Dynamics (CFD) simulation. Two types of swirl flow generator: Classical twisted tape (CTT) and Parabolic-cut twisted tape (PCT) with a different twist ratio (= 2.93, 3.91 and 4.89) and different cut depth (= 0.5, 1.0 and 1.5 cm) with 2% and 4% volume concentration
... Show MoreSevere Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) has caused enormous issues worldwide and is the most infectious pandemic. This study included 50 subjects (evenly distributed between sexes) and their range of ages starting from 2 to 67 years. According to the study's result, the ages and genders of subjects include susceptibility to COVID-19. Males were found to be more infected than females, and the ages of 36 to 67 were more common than other age ranges. Also, BMI calculations revealed that male patients with COVID-19 have the highest percentage of obesity. The clinical parameter results have been found serum C‐reactive protein (CRP) as an essential indicator that changes significantly in infection with COVID‐19 an
... Show MoreThe study of the distribution of major oxides and heavy metals in some plants collecting and analyzing eighteen plant samples of vegetables including carrot, onion, eggplant, cucumber, and okra obtained from Abu Ghraib land located about 20 km west of Baghdad, Iraq. Eighteen plant samples of vegetables,.Heavy metals can have a severe impact if released into the environment, even in trace quantities. These can enter the food chain from aquatic and agricultural ecosystems and indirectly threaten human health.. Trace elements and oxides of As, Cd, Co, Cr, Cu, Mn, Mo, Ni, Pb, Se, Th, U, V, and Zn were measured in plant samples using an X-Ray Fluorescence Instrument (XRF). TEs analyses of vegetables were performed in the Iraqi German Lab
... Show MoreA simple reverse-phase high performance liquid chromatographic method for the simultaneous analysis (separation and quantification) of furosemide (FURO), carbamazepine (CARB), diazepam (DIAZ) and carvedilol (CARV) has been developed and validated. The method was carried out on a NUCLEODUR® 100-5 C18ec column (250 x 4.6 mm, i. d.5μm), with a mobile phase comprising of acetonitrile: deionized water (50: 50 v/v, pH adjusted to 3.6 ±0.05 with acetic acid) at a flow rate 1.5 mL.min-1 and the quantification was achieved at 226 nm. The retention times of FURO, CARB, DIAZ and CARV were found to be 1.90 min, 2.79 min, 5.39 min and 9.56 min respectively. The method was validated in terms of linearity, accuracy, precision, limit of detection and li
... Show More