Short-term effect of ultrasound therapy on stiffness elbow joint
...Show More Authors

Elbow stiffness is hard to treat and commonly resulted from trauma or degenerative arthritis. This study aimed to demonstrate the effectiveness of using ultrasound therapy in management of stiff elbow joint resulted from several etiological factors. A total number of 42 patients (35 male and 7 female) allocated randomly from the Department of Physiotherapy at Al-yarmouk Teaching Hospital during 2013. Each patient examined physically by physiotherapist taking in consideration the measurement of the joint movement angle using goniometer in flexion and the extension, and the pain score using visual analogue scale (VAS). Ultrasound therapy initiated thrice weekly for two weeks. At the time of entry, the means degree of flexion and extension movements were 148.45 and 113.33º. Ultrasound therapy significantly reduced the pain from of 1.238±0.932 to 0.38± 0.538score. Significant improvement observed in patients aged more than 20 years and the improvement in flexion elbow significantly correlated with the frequency of ultrasound. In Conclusions ultrasound therapy is safe, effective and provided pain relieve as well as wide range of movement in post-traumatic elbow stiffness.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Aug 31 2022
Journal Name
Al-kindy College Medical Journal
Automated breast ultrasound: A comparison study with handheld ultrasound in detection and characterization of lesions in mammographically dense breast
...Show More Authors

Background: Although mammography is a powerful screening tool in detection of early breast cancer, it is imperfect, particularly for women with dense breast, which have a higher risk to develop cancer and decrease the sensitivity of mammogram, Automated breast ultrasound is a recently introduced ultrasonography technique, developed with the purpose to standardize breast ultrasonography and overcome some limitations of handheld ultrasound, this study aims to evaluate the diagnostic efficacy of Automated breast ultrasound and compare it with handheld ultrasound in the detection and characterization of breast lesions in women with dense breasts. Objectives: To evaluate the diagnostic efficacy of Automated breast ultrasound and compare

... Show More
Crossref (1)
Crossref
Publication Date
Sun Dec 05 2010
Journal Name
Baghdad Science Journal
Effect of Granulocyte-colony stimulating factor with or without Moxifloxcacin therapy on capsulated Staphylococcus aureus infection in neutropenic mice
...Show More Authors

Twenty bacterial isolates were identified as Staphylococcus aureus collected from wounds and catheters related infections. A capsulated S. aureus isolate was chosen after performing serum soft agar test, for this study Neutropenic mice were challenged with capsulated S. aureus ,and the effect of G-CSF with or without moxifloxacin was studied. The results indicated that the addition of G-CSF to moxifloxacin therapy have a synergistic effect in the killing of the bacteria, while when each G-CSF and moxifloxacin were used seperately have a similar effect on bacterial killing. It was found that the moxifloxacin has the same activity as G_CSF but is less costly than the latter one.

View Publication Preview PDF
Crossref
Publication Date
Tue Dec 01 2020
Journal Name
Minar International Journal Of Applied Sciences And Technology
INNOVATE GESTATIONAL AGE ESTIMATION MODEL FOR IRAQI FETUSES BASED ON ULTRASOUND IMAGES MEASUREMENTS
...Show More Authors

Imaging by Ultrasound (US) is an accurate and useful modality for the assessment of gestational age (GA), estimation fetal weight, and monitoring the fetal growth during pregnancy, is a routine part of prenatal care, and that can greatly impact obstetric management. Estimation of GA is important in obstetric care, making appropriate management decisions requires accurate appraisal of GA. Accurate GA estimation may assist obstetricians in appropriately counseling women who are at risk of a preterm delivery about likely neonatal outcomes, and it is essential in the evaluation of the fetal growth and detection of intrauterine growth restriction. There are many formulas are used to estimate fetal GA in the world, but it's not specify fo

... Show More
View Publication
Crossref
Publication Date
Sat Dec 01 2018
Journal Name
Al-khwarizmi Engineering Journal
Semi-Active Damping of Mechanical Vibrating Systems Using Variable Stiffness Actuator
...Show More Authors

      In this research, a variable stiffness actuator is proposed to enhance the damping of the mechanical vibrating system. The frequency response analysis of the vibrating system is dependant in order to analyze and synthesis this semi-active damping, where the suggested process is using active filter to estimate the present frequency of the vibration system, and this will limit the value of the stiffness of the vibrated system. Two active filter s are needed, low-pass-filter (LPF) to choose the higher stiffness of the actuator at small frequencies as well as more damping and high-pass-filter (HPF) to choose the lower stiffness of the actuator at high frequencies as well as more damping, and so

... Show More
View Publication Preview PDF
Publication Date
Mon Sep 28 2020
Journal Name
Journal Of Physical Education
The Effect of Increasing Rehabilitation Program Using Electric Stimulation On Rehabilitating Knee Joint Working Muscles Due to ACL Tear In Athletes
...Show More Authors

The research aimed at designing a rehabilitation program using electric stimulation for rehabilitating knee joint working muscles as a result of ACL tear using an apparatus developed by the researchers that stimulate the muscle vibration and work as well as the ability to rehabilitate the join in shorter periods. In addition to that, it aimed at identifying the effect of this program on rehabilitating the knee joint working muscles. The researchers used the experimental method on Baghdad clubs’ players who suffer from complete knee joint ACL tear aged (19 – 24) years old. The results showed that the training program developed the working muscles significantly achieving normal levels of activity.

Crossref
Publication Date
Mon Mar 01 2010
Journal Name
Al-khwarizmi Engineering Journal
The Effect of Mechanical Combined Contact Stress with Buckling Load on the Stress Distribution in the Ball and Socket Joint Mechanism
...Show More Authors

The design of components subjected to contact stress as local compressive stress is important in engineering application especially in ball and socket Joining.  Two kinds of contact stress are introduced in the ball and socket joint, the first is from normal contact while the other is from sliding contact. Although joining two long links (drive shaft in steering cars) will cause the effect of flexural and tensional buckling stress in hollow columns through the ball and socket ends on the failure condition of the joining mechanism. In this paper the consideration of the combined effect of buckling Load and contact stress on the ball and socket joints have been taken, epically on the stress distribution in the contact area. Different

... Show More
View Publication Preview PDF
Publication Date
Tue Dec 01 2020
Journal Name
Journal Of Economics And Administrative Sciences
The effect of the Iraqi dinar exchange rate on inflation and economic growth using the joint integration methodology "a standard study"
...Show More Authors

The exchange rate is of great importance at the global and local levels alike, as this importance increases with the increasing rates of development of economic relations between countries of the world due to openness and integration into the global economy, expressed by the expansion of the volume of trade and financial relations between countries. The Central Bank of Iraq has set the need to stabilize this price as a goal to reduce inflation rates and reduce them to the internationally accepted rates by using the foreign currency sale window to achieve a balance between the forces of supply and demand for foreign currency and to preserve the value of the Iraqi dinar. The research concluded that the central bank was It has a maj

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Jun 26 2026
Journal Name
Journal Of Physical Education
The Effect of Increasing Rehabilitation Program Using Electric Stimulation On Rehabilitating Knee Joint Working Muscles Due to ACL Tear In Athletes
...Show More Authors

View Publication
Publication Date
Mon Jan 01 2024
Journal Name
Scripta Medica
Effect of proteolytic enzymes and insulin sensitiser in treatment of joint osteoarthritis in diabetic patients
...Show More Authors

Background/Aim: Knee osteoarthritis is a frequently crippling chronic condition. Numerous pharmacological medications have been successfully utilised to treat knee osteoarthritis. This research aimed to compare the efficiency of metformin and serratiopeptidase in treating and preventing osteoarthritis development via distinct mechanisms. Methods: Between 1 January and 30 May 2019, a randomised-clinical-trial was done at Al-Kindy Hospital on 80 osteoarthritis patients, divided in two groups. Group I was given metformin 850 mg orally, whereas Group II was given serratiopeptidase 20 mg and metformin 850 mg orally. Parameters in these groups were compared with forty healthy normal controls. Results: Following treatment, patients in Grou

... Show More
View Publication
Scopus (3)
Scopus Crossref
Publication Date
Wed Feb 22 2023
Journal Name
Iraqi Journal Of Science
The Effect of Short Range Correlation on The Nuclear Charge Density Distribution, Elastic and Inelastic Electron Scattering Coulomb Form Factors of 18O Nucleus
...Show More Authors

The effect of short range correlations on the inelastic longitudinal Coulomb form
factors for the lowest four excited 2+ states in 18O is analyzed. This effect (which
depends on the correlation parameter β) is inserted into the ground state charge
density distribution through the Jastrow type correlation function. The single particle
harmonic oscillator wave function is used with an oscillator size parameter b. The
parameters β and b are, considered as free parameters, adjusted for each excited state
separately so as to reproduce the experimental root mean square charge radius of
18O. The model space of 18O does not contribute to the transition charge density. As
a result, the inelastic Coulomb form factor of 18

... Show More