In this work, varying compositions of SiO2 micro filler were added
with the Polyvinyl Chloride (PVC) and samples have been prepared
using film casting technique. The results have been analyzed and
compared for PVC samples with (1 wt%, 3 wt%, 5 wt% and 10 wt%)
SiO2 micro filler. Mechanical characteristics such as tensile strength,
elongation at break and Young`s modulus were measured for all the
samples, where the tensile strength was increased from 8.39 Mpa for
purified PVC to 16 Mpa for 3% SiO2/PVC composite. Also, thermal
conductivity measurement values illustrated that composite materials
have a good thermal insulation at 10 wt. %, thermal conductivity was
decreased from 0.1684 W/m. K for PVC to 0.1310W/m. K at 10%
SiO2/PVC composite. Absorptivity test was also carried out for these
samples, the results of this study proved that PVC and SiO2-PVC
composites have low diffusion coefficients ranging from (10-13- 10-10
m2/s). Similarly, the dielectric properties like dielectric constant, loss
factor, resistance, and volume resistivity were performed; the
dielectric constant was increased from 2.1039 for PVC to 3.658 for
3% SiO2/PVC composites, while the dielectric loss factor was
decreased from 0.0144 for PVC to 0.0137 for 5%SiO2/PVC
composite. The values of resistance were increased from
17259.99(Ω) for purified PVC to 29185.75(Ω) for 10% SiO2/PVC
composites. Volume resistivity was increased from 0.3794 x109 (Ω.
cm) for PVC to 0.5179x109 (Ω. cm) for 10% SiO2/PVC composites.
FTIR spectroscopy was employed for all PVC-composite samples
and its results were investigated, there are systematic increases in
absorbance intensity spectra with SiO2 ratios attributed to good
distribution of inorganic fillers (Symmetric increases). The
microstructure and morphology of the prepared samples were
investigated by using optical microscope. It can be observed that, the
samples with (3% SiO2/PVC) are glossy and smooth without
agglomeration of (SiO2) particles in (PVC) matrix. The results
demonstrate that PVC-composite films prepared in this study show
promising potential to achieve good materials for plastic packaging
applications.
2-benzamide benzothiazole complexes of Pd(II) , Pt(IV) and Au(III) ions were prepared by microwave assisted radiation. The ligand and the complexes were isolated and characterized in solid state by using FT-IR, UV-Vis spectroscopy, flame atomic absorption, elemental analysis CHNS , magnetic susceptibility measurements , melting points and conductivity measurements. The nature of complexes in liquid state was studied by following the molar ratio method which gave results approximately identical to those obtained from isolated solid state; also, stability constant of the prepared complexes were studied and found that they were stable in molar ratio 1:1.The complexes have a sequar planner geometry except Pt(IV) complex has octahedral .
... Show MoreHerein, date palm (Phoenix dactylifera) bunch (DPB) waste was transformed into activated carbon (DPAC) adsorbent by using microwaveinduced ZnCl2 activation for 15 min at a power of 600 W. Several analytical methods were used to explain the physicochemical parameters of DPBAC including XRD, pHpzc, BET, SEM–EDX, and FTIR. Afterwards, the adsorptive performance of DPBAC was thoroughly investigated for the removal of two structurally different organic dyes namely methyl violet (MV) and fuchsin basic (FB). The key adsorption parameters, including the dose of DPBAC (A: 0.02–0.06 g), the solution pH (B: 4–10), and the contact time (C: 2–20 min) were statistically optimized using the Box-Behnken design with response surface methodology (RSM
... Show MoreABSTRACT Backgrounds: Maxillary canine impaction is complicated and time consuming to treat, for being highly diverse in inclination and location; it may be a companied by root resorption of the neighboring teeth. CBCT has been used for its' diagnostic reliability in localization of impacted canine and revealing its' serious local complications. Objectives: Localization of maxillary impacted canine using cone beam computed tomography for assessment of angulation, distance from occlusal plane, alveolar width and proximity to adjacent teeth. Subjects and Methods: The study sample was 33 subjects 16 females and 17 males attended to Al-Wasitti general hospital in Baghdad city-Oral and maxillofacial radiology department for CBCT scan investigati
... Show MoreBackground: Ultrasonography has been used to examine the thickness of the lower uterine segment in women with previous cesarean sections in an attempt to predict the risk of scar dehiscence during subsequent pregnancy. The predictive value of such measurement has not been adequately assessed. Objectives: To correlate lower uterine segment thickness measured by trans abdominal ultrasound in pregnant women with previous cesarean section with that measured during cesarean section by caliper and to find out minimum lower uterine segment thickness indicative of integrity of the scar.Methods: A prospective observational study at Elwyia Maternity Teaching Hospital, from January 2011 to January 2012. A total of 143 women were enrolled in the stu
... Show MoreAbstract:
The aerial part of Ephedra foliata Family Ephedraceae have long been used in traditional medicine and now Ephedra species have medicinal, ecological, and commercial value. The variety of pharmacological actions of this plant is due to its chemical constituents. Ephedrine and
related alkaloids; are the newly potential medicinal value of Ephedra supplements for weight loss or performance improvement. Other pharmacological actions like antibacterial and antifungal effects of the phenolic acid compounds, the immunosuppressive action of the polysaccharides, and the antitumor action of flavonoids. The genus of this plant wildly distributed t