Preferred Language
Articles
/
ijp-250
Estimation of electron temperature for SiO2 plasma induced by laser
...Show More Authors

In this work; Silicon dioxide (SiO2) were fabricated by pulsed
laser ablation (PLA). The electron temperature was calculated by
reading the data of I-V curve of Langmuir probe which was
employed as a diagnostic technique for measuring plasma properties.
Pulsed Nd:YA Glaser was used for measuring the electron
temperature of SiO2 plasma plume under vacuum environment with
varying both pressure and axial distance from the target surface. The
electron temperature has been measured experimentally and the
effects of each of pressure and Langmuir probe distance from the
target were studied. An inverse relationship between electron
temperature and both pressure and axial distance was observed.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Dec 20 2021
Journal Name
Baghdad Science Journal
Design of L-Band Multiwavelength Laser for TDM/WDM PON Application
...Show More Authors

This paper presents on the design of L-Band Multiwavelength laser for Hybrid Time Division Multiplexing/ Wavelength Division Multiplexing (TDM/WDM) Passive Optical Network (PON) application. In this design, an L-band Mulltiwavelength Laser is designed as the downstream signals for TDM/WDM PON. The downstream signals ranging from 1569.865 nm to 1581.973 nm with 100GHz spacing. The multiwavelength laser is designed using OptiSystem software and it is integrated into a TDM/WDM PON that is also designed using OptiSystem simulation software. By adapting multiwavelength fiber laser into a TDM/WDM network, a simple and low-cost downstream signal is proposed. From the simulation design, it is found that the proposed design is suitable to be used

... Show More
View Publication Preview PDF
Scopus (3)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Fri Jan 01 2016
Journal Name
Journal Of College Of Education
An Investigative Study on the Electron Energy Distribution Function and Electron Transport Coefficients in SF6 -- Ne Gas Mixtures
...Show More Authors

Preview PDF
Publication Date
Sat May 15 2004
Journal Name
Journal Of Biotechnology Research Center
The Morphological and Histopathological Liver Abnormalities Caused by Carbamazepine-Induced Injury in Female Albino Mice
...Show More Authors

Background: The adverse effects of drugs can damage various organs, especially the liver, leading to a hepatic injury known as hepatotoxicity. Drug-induced liver injury (DILI) is challenging nowadays because of the large number of different drugs used, one of the offending medications that cause DILI is carbamazepine (CBZ), since the liver has an array of functions including detoxification, it will deal with several damages caused by exposure to the drugs. Objective: investigate the effect of (CBZ) 20mg/kg/day on female mice liver after 14 and 30 days of treatment on morphological and histopathological levels. Materials and Methods: 20mg/kg/day of CBZ was administered orally for (14) days to (10) female mice, another (10) mice were taking t

... Show More
Publication Date
Wed Jul 01 2020
Journal Name
Biochemical And Cellular Archives
Histopathological changes in liver induced by piroxicam administration in adult male albino mice mus musculus
...Show More Authors

Scopus (3)
Scopus
Publication Date
Mon Oct 01 2012
Journal Name
Iraqi Journal Of Physics
Effect of nano and micro SiO2 weight percent on interlaminar fracture toughness of woven roving/ epoxy composites
...Show More Authors

Effect of nano and micro SiO2 particles with different weight percent (2,4,6,8 and 10) %wt on the Interlaminar fracture toughness (GIc) of 16-plies of woven roving glass fiber /epoxy composites prepared by hand lay – up technique were investigated. The specimens were tested using DCB test (mode I).
Area method was used to compute the interlaminar fracture toughness. The results show that, GIc would increase with the increasing in the filler content, the main failure in microcomposites and nanocomposites was delamination in the layers, the delamination reduced with increasing in the filler content.

View Publication Preview PDF
Publication Date
Mon Feb 18 2019
Journal Name
Iraqi Journal Of Physics
Elastic transverse electron scattering form factors of 11Li exotic nucleus
...Show More Authors

        The elastic transverse electron scattering form factors have been studied for the 11Li   nucleus using the Two- Frequency Shell Model (TFSM) approach. The single-particle wave functions of harmonic-oscillator (HO) potential are used with two different oscillator parameters bcore and bhalo. According to this model, the core nucleons of 9Li nucleus are assumed to move in the model space of spsdpf. The outer halo (2-neutron) in 11Li is assumed to move in the pure 1p1/2, 1d5/2, 2s1/2 orbit. The shell model calculations are carried ou

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Jan 13 2019
Journal Name
Iraqi Journal Of Physics
Inelastic longitudinal electron scattering C42 form factors in42Ti nucleus
...Show More Authors

Inelastic longitudinal electron scattering form factors for second
excited state C42 in 42Ti nucleus have been calculated using shell
model theory. Fp shell model space with configuration (1f7/2 2p3/2
1f5/2 2p1/2) has been adopted in order to distribute the valence
particles (protons and neutrons) outside an inert core 40Ca. Modern
model space effective interactions like FPD6 and GXPF1 have been
used to generate model space vectors and harmonic oscillator wave
function as a single particle wave function. Discarder space (core
orbits + higher orbits) has been included in (core polarization effect)
as a first order correction in microscopic theory to measure the
interested multipole form factors via the model

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Dec 15 2011
Journal Name
Iraqi Journal Of Laser
Different Wavelength Femtosecond Laser Pulses Generated by Diode Pumped Ti: Sapphire Crystal
...Show More Authors

The relation between the output power and wavelengths for a 532nm 3W frequency doubled diode pumped solid state laser pumped Ti:Sapphire crystal is investigated. A 20 femtosecond pulse at 800 nm is obtained. A 320 mW is found to be the highest power at 800nm. Below this wavelength value and above the power was found to deviate from highest output value.

View Publication Preview PDF
Publication Date
Thu Jan 11 2018
Journal Name
Al-khwarizmi Engineering Journal
Experimental Estimation of Critical Buckling Velocities for Conservative Pipes Conveying Fluid
...Show More Authors

Conservative pipes conveying fluid such as pinned-pinned (p-p), clamped–pinned (c-p) pipes and clamped-clamped (c-c) lose their stability by buckling at certain critical fluid velocities. In order to experimentally evaluate these velocities, high flow-rate pumps that demand complicated fluid circuits must be used.

     This paper studies a new experimental approach based on estimating the critical velocities from the measurement of several fundamental natural frequencies .In this approach low flow-rate pumps and simple fluid circuit can be used.

Experiments were carried out on two pipe models at three different boundary conditions. The results showed that the present approach is more accurate for est

... Show More
View Publication Preview PDF
Publication Date
Thu Jan 16 2020
Journal Name
Periodicals Of Engineering And Natural Sciences
Comparison of some reliability estimation methods for Laplace distribution using simulations
...Show More Authors

In this paper, we derived an estimator of reliability function for Laplace distribution with two parameters using Bayes method with square error loss function, Jeffery’s formula and conditional probability random variable of observation. The main objective of this study is to find the efficiency of the derived Bayesian estimator compared to the maximum likelihood of this function and moment method using simulation technique by Monte Carlo method under different Laplace distribution parameters and sample sizes. The consequences have shown that Bayes estimator has been more efficient than the maximum likelihood estimator and moment estimator in all samples sizes