Preferred Language
Articles
/
ijp-198
Determination the concentration of radon in human urine using LR-115 detector
...Show More Authors

In the present study twenty samples of human urine were taken
from healthy male and female with different of: ages, occupation and
place of residence. These samples were collected from the hospital to
measure the concentration of radon gas in human urine by using one
of solid state nuclear track detectors LR-115.
The results obtained of the concentrations of radon in healthy human
urine are varying from 2.12×10-3 Bq.l-1 to 4.42×10-3 Bq.l-1 and
these values are less than the allowed limits 12.3×10-3 Bq.l-1.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Mar 29 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Acquired Error in using Antibiotic for Surgery Patients in Iraqi Hospitals
...Show More Authors

The use of antibiotics (AB) in surgery focused in either treating established infection or to prevent suspected post-operative infection. Inappropriate use of antibiotic for treatment of patients with common infections is a major problem worldwide, with great implications with regards to cost of treatment and development of resistance to the antimicrobial agent. Moreover, antibiotics may often be dispensed without a clear clinical indication. This study was conducted to estimate the medication errors in using antibiotic for surgery patients which may effect their wound healing. A 260 patients with clean-contaminated and contaminated surgery were included from two teaching hospitals, 160 patient from Medical city hospital and 100 from Al-

... Show More
View Publication Preview PDF
Scopus (3)
Crossref (1)
Scopus Crossref
Publication Date
Wed Mar 29 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Acquired Error in using Antibiotic for Surgery Patients in Iraqi Hospitals
...Show More Authors

The use of antibiotics (AB) in surgery focused in either treating established infection or to prevent suspected post-operative infection. Inappropriate use of antibiotic for treatment of patients with common infections is a major problem worldwide, with great implications with regards to cost of treatment and development of resistance to the antimicrobial agent. Moreover, antibiotics may often be dispensed without a clear clinical indication. This study was conducted to estimate the medication errors in using antibiotic for surgery patients which may effect their wound healing. A 260 patients with clean-contaminated and contaminated surgery were included from two teaching hospitals, 160 patient from Medical city hospital and 100 fro

... Show More
Scopus (3)
Crossref (1)
Scopus Crossref
Publication Date
Sun Sep 01 2013
Journal Name
Journal Of Economics And Administrative Sciences
Using Six-Sigma to measure the quality performance of the Department of Statistics-University of Baghdad-Case Study
...Show More Authors

Abstract

            This research was to provide a definition of quality, dimensions and concepts, whether traditional or modern concept, as well as review the dimensions of quality in higher education and vision and mission with the overall objectives of the Statistics Department.

         After reviewing quality goals and purposes achieved as well as the mechanisms used to achieve them. and use standard Six-Sigma as one of the methodologies used in quality with the historical roots of using this methodology and methods applied and their definitions t

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Dec 30 2023
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Biosorption of Ciprofloxacin (CIP) using the Waste of Extraction Process of Microalgae: The Equilibrium Isotherm and Kinetic Study
...Show More Authors

       Scientists are investigating the efficacy of different biosorbents for promoting economic and environmental viability in purifying contaminants. Among the primary by-products of biodiesel production is waste microalgae biomass, which has the potential to be used as a cheap biosorbent for the treatment of pollution. In the present study, the biomass left over after extracting the chlorella vulgaris was used to test the potential biosorption of CIP from simulated aqueous solutions. Bisorbent's ability was characterized using Fourier transform infrared spectroscopy (FTIR), scanning electron microscopy (SEM), and energy-dispersive X-ray spectroscopy (EDX). Analysis with a Fourier Transform Infrared Spectrometer revealed that C

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Sat Apr 23 2016
Journal Name
Iraqi Journal Of Agricultural Sciences
MEASURRING COW FARMS EFFICIENCY BY USING THE QUALITY RESPONSE
...Show More Authors

In despite of the expansion of using the dummy variables as a explanatory variables, but their using as a dependent variables is still limited, and the reason of that may be return to may problems when using dummy variables as a dependent variables. the study aimed to using the quality Response Models to Measuring Efficiency of cows farms by random sample including (19) farm from (Abi gherak district). The study estimating the transcendental logarithmic production function by using stochastic frontier Analysis (SFA) to interpret the relation between the return achieved from the cows farms as a dependent variables and each of labor and capital as an independent variables. the function indicates that increasing in labor by (100%) will

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Mon Dec 18 2017
Journal Name
Al-khwarizmi Engineering Journal
Reducing the Water Hardness by Using Electromagnetic Polarization Method
...Show More Authors

Hard water does not pose a threat to human health but may cause precipitation of soap or results stone in the boilers. These reactions are caused by the high concentrations of Ca and Mg. In the industry they are undesirable because of higher fuel consumption for industrial use .Electromagnetic polarization water treatment is a method which can be used for increasing the precipitation of Ca 2+ and CO3 2- ions in hard water to form CaCO3 which leads to decrease the water hardness is research has been conducted by changing the number of coil turns and voltage of the system. The spectroscopy electron microscope was used for imaging the produced crystals. Results of the investigation indicated that

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Sat Jan 01 2022
Journal Name
Urology Annals
Modified snodgrass hypospadias repair using the lembert suturing technique
...Show More Authors

View Publication
Scopus (1)
Scopus Clarivate Crossref
Publication Date
Tue Jun 01 2021
Journal Name
Journal Of Optical Communications
Improving the optical link for UVLC using MIMO technique
...Show More Authors
Abstract<p>This paper proposed a theoretical treatment to study underwater wireless optical communications (UWOC) system with different modulation schemes by multiple input-multiple output (MIMO) technology in coastal water. MIMO technology provides high-speed data rates with longer distance link. This technique employed to assess the system by BER, Q. factor and data rate under coastal water types. The reliability of the system is examined by the techniques of 1Tx/1Rx, 2Tx/2Rx, 3Tx/3Rx and 4Tx/4Rx. The results shows the proposed technique by MIMO can get the better performance compared with the other techniques in terms of BER. Theoretical results were obtained to compare between PIN and APD </p> ... Show More
View Publication
Scopus (21)
Crossref (21)
Scopus Crossref
Publication Date
Mon Feb 22 2021
Journal Name
Periodicals Of Engineering And Natural Sciences (pen)
MRI images series segmentation using the geodesic deformable model
...Show More Authors

View Publication
Scopus Crossref
Publication Date
Fri Apr 30 2010
Journal Name
Journal Of Applied Computer Science & Mathematics
Image Hiding Using Magnitude Modulation on the DCT Coefficients
...Show More Authors

In this paper, we introduce a DCT based steganographic method for gray scale images. The embedding approach is designed to reach efficient tradeoff among the three conflicting goals; maximizing the amount of hidden message, minimizing distortion between the cover image and stego-image,and maximizing the robustness of embedding. The main idea of the method is to create a safe embedding area in the middle and high frequency region of the DCT domain using a magnitude modulation technique. The magnitude modulation is applied using uniform quantization with magnitude Adder/Subtractor modules. The conducted test results indicated that the proposed method satisfy high capacity, high preservation of perceptual and statistical properties of the steg

... Show More
View Publication Preview PDF