Preferred Language
Articles
/
ijp-1150
Gas Sensor for Hazardous Nitrogen Dioxide Based on TiO2 Nanotube Synthesis via Electrochemical Method
...Show More Authors

Because of the quick growth of electrical instruments used in noxious gas detection, the importance of gas sensors has increased. X-ray diffraction (XRD) can be used to examine the crystal phase structure of sensing materials, which affects the properties of gas sensing. This contributes to the study of the effect of electrochemical synthesis of titanium dioxide (TiO2) materials with various crystal phase shapes, such as rutile TiO2 (R-TiO2NTs) and anatase TiO2 (A-TiO2NTs). In this work, we have studied the effect of voltage on preparing TiO2 nanotube arrays via the anodization technique for gas sensor applications. The results acquired from XRD, energy dispersion spectroscopy (EDX), and field emission scanning electron microscopy (FE-SEM) elucidate that TiO2 was created. In addition, systematically examining the gas detection properties was also done. The gas sensor was produced from TiO2 nanotubes, and the gas-detecting features were directed at nitrogen dioxide (NO2), which is a hazardous gas. The sensor formed from TiO2 nanotubes detects NO2 gas at various temperatures, from room temperature to    300 oC, and it has good sensitivity to this gas. The results exhibit that the gas sensor that was synthesized at 30 V has good sensitivity and a short response time at room temperature for NO2 gas sensing.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Feb 07 2019
Journal Name
Iraqi Journal Of Laser
In Growing Toenail Treatment using Carbon Dioxide Laser
...Show More Authors

An ingrowing toenail is a common problem affecting mainly adolescents and young adults, with a male predominance of 3:1. The disorder generally occurs in big toes. It is painful and often chronic and it affects work and social activities. Most patients initially complain of pain and later discharge, infection and difficulty in walking occur. The Objectives: The purpose of the study was to evaluate the efficacy and safety of (10600nm) CO2 laser in the treatment of ingrowing toe nail. Patients, Materials & Methods: This study was done in laser medicine research clinics from July 2013 to the end of December 2013; 10 patients including 7(70%) males and 3 (30%) females with age ranging from 18 years to 70 years with mean age of 44 years o

... Show More
View Publication Preview PDF
Publication Date
Tue Jun 01 2021
Journal Name
Iop Conference Series: Earth And Environmental Science
Carbon dioxide capture using nonwoven activated carbon nanofiber
...Show More Authors
Abstract<p>The adsorption isotherms and kinetic uptakes of Carbon Dioxide (CO2) on fabricated electrospun nonwoven activated carbon nanofiber sheets were investigated at two different temperatures, 308 K and 343 K, over a pressure range of 1 to 7 bar. The activated carbon nanofiber-based on polymer (PAN) precursor was fabricated via electrospinning technique followed by thermal treatment to obtain the carboneous nanofibers. The obtained data of CO2 adsorption isotherm was fitted to various models, including Langmuir, Freundlich, and Temkin. Based on correlation coefficients, the Langmuir isotherm model presented the best fitting with CO2 adsorption isotherms’ experimental data. Raising the equ</p> ... Show More
View Publication
Scopus (9)
Crossref (5)
Scopus Crossref
Publication Date
Mon Jun 04 2018
Journal Name
Baghdad Science Journal
The Effect of Gas Flow on Plasma Parameters Induced by Microwave
...Show More Authors

In this paper, construction microwaves induced plasma jet(MIPJ) system. This system was used to produce a non-thermal plasma jet at atmospheric pressure, at standard frequency of 2.45 GHz and microwave power of 800 W. The working gas Argon (Ar) was supplied to flow through the torch with adjustable flow rate by using flow meter, to diagnose microwave plasma optical emission spectroscopy(OES) was used to measure the important plasma parameters such as electron temperature (Te), residence time (Rt), plasma frequency (?pe), collisional skin depth (?), plasma conductivity (?dc), Debye length(?D). Also, the density of the plasma electron is calculated with the use of Stark broadened profiles

View Publication Preview PDF
Scopus (19)
Crossref (7)
Scopus Clarivate Crossref
Publication Date
Fri Dec 31 2021
Journal Name
Iraqi Journal Of Laser
The influence of no-core fibre length on the sensitivity Optical fibre Humidity sensor
...Show More Authors

Abstract: Reflection optical fibre Humidity sensor is presented in this work, which is based on no core fibre prepared by splicing a segment of no core fibre (NCF) at different lengths 1-6 cm with fixed diameter 125 µm and a single mode fibre (SMF). The range of humidity inside the chamber is controlled from 30% to 90% RH at temperature ~ 30 °С. The experimental result shows that the resonant wavelength dip shift decreases linearly with an increment of RH% and the sensitivity of the sensor increased linearly with an increasing in the length of NCF. However, a high sensitivity 716.07pm/RH% is obtained at length 5cm with good stability and reputability.  Furthermore, the sensor is shif

... Show More
View Publication Preview PDF
Publication Date
Tue May 23 2023
Journal Name
Journal Of Sensors
On-Board Digital Twin Based on Impedance and Model Predictive Control for Aerial Robot Grasping
...Show More Authors

Aerial manipulation of objects has a number of advantages as it is not limited by the morphology of the terrain. One of the main problems of the aerial payload process is the lack of real-time prediction of the interaction between the gripper of the aerial robot and the payload. This paper introduces a digital twin (DT) approach based on impedance control of the aerial payload transmission process. The impedance control technique is implemented to develop the target impedance based on emerging the mass of the payload and the model of the gripper fingers. Tracking the position of the interactional point between the fingers of gripper and payload, inside the impedance control, is achieved using model predictive control (MPD) approach.

... Show More
View Publication
Scopus (4)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Sat Jan 01 2022
Journal Name
Journal Of Petroleum Science And Engineering
Performance evaluation of analytical methods in linear flow data for hydraulically-fractured gas wells
...Show More Authors

View Publication
Scopus (8)
Crossref (8)
Scopus Clarivate Crossref
Publication Date
Mon Feb 04 2019
Journal Name
Iraqi Journal Of Physics
A study of the Zn:Sn mixing ratio effect on the gas detector properties
...Show More Authors

Semiconductor-based metal oxide gas detector of five mixed from zinc chloride Z and tin chloride S salts Z:S ratio 0, 25, 50, 75 and 100% were fabricated on glass substrate by a spray pyrolysis technique. With thickness were about 0.2 ±0.05 μm using water soluble as precursors at a glass substrate temperature 500 ºC±5, 0.05 M, and their gas sensing properties toward CH4, LPG and H2S gas at different concentration (10, 100, 1000 ppm) in air were investigated at room temperature which related with the petroleum refining industry.
Furthermore structural and morphology properties were scrutinize. Results shows that the mixing ratio affect the composition of formative oxides were (ZnO, Zn2SnO4, Zn2SnO4+ZnSnO3, ZnSnO3, SnO2) ratios ment

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Oct 01 2011
Journal Name
Iraqi Journal Of Physics
Some gas sensing properties of PbS thin films
...Show More Authors

In this research PbS thin film have been prepared by chemical bath deposition technique (CBD).The PbS film with thickness of (1-1.5)μm was thermally treated at temperature of 100°C for 4 hours. Some Structural characteristics was studied by using X-ray diffraction (XRD)and optical microscope photograph some of chemical gas sensing measurements were carried out ,it shown that the sensitivity of (CO2) gas depend on the grain Size and deposition substrate. The grain size of PbS film deposited on on glass closed to 21.4 nm while 37.97nm for Si substrate. The result of current-voltage characterization shwon the sensitivity of prepared film deposited on Si better than film on glass.

View Publication Preview PDF
Publication Date
Thu Aug 11 2016
Journal Name
Advanced Materials
Contact Resistance Effects in Highly Doped Organic Electrochemical Transistors
...Show More Authors

View Publication
Scopus (56)
Crossref (57)
Scopus Clarivate Crossref
Publication Date
Wed Sep 12 2018
Journal Name
Journal Of Global Pharma Technology
Electrochemical Determination of Tetracycline at SPCE modified with Nanocomposite
...Show More Authors

An electrochemical sensor based on manganese dioxide nanorodMnO2and Graphene oxide (GO) functionalized with 4-amino, 3-substituted 1H, 1, 2, 4 Triazole 5(4H) thion (FGO)/MnO2Nanocompositewas developed for voltammetric determination of Tetracycline (TET).The working electrode WE of SPCE was modified bya drop casting method. X-ray powder diffractometer (XRD), scanning electron microscopy (SEM) and FT-IR were employed to characterize the synthesized FGO/MnO2. The determination of TET at the modified electrode was studied by cyclic voltammetry (CV) and differential pulse voltammetry (DPV) in the phosphate buffer solution (PBS).TET show sharp increase in the oxidation peaks in the pH 2.Voltammetric characteristics of TET (Epa, Ipa) were estimate

... Show More
Preview PDF