Preferred Language
Articles
/
ijp-1123
Surface Plasmon Resonance (SPR)-Based Multimode Optical Fiber Sensors for Electrical Transformer Oil Aging Detection
...Show More Authors

I

In this study, optical fibers were designed and implemented as a chemical sensor based on surface plasmon resonance (SPR) to estimate the age of the oil used in electrical transformers. The study depends on the refractive indices of the oil. The sensor was created by embedding the center portion of the optical fiber in a resin block, followed by polishing, and tapering to create the optical fiber sensor. The tapering time was 50 min. The multi-mode optical fiber was coated with 60 nm thickness gold metal. The deposition length was 4 cm. The sensor's resonance wavelength was 415 nm. The primary sensor parameters were calculated, including sensitivity (6.25), signal-to-noise ratio (2.38), figure of merit (4.88), and accuracy (3.2). In the current study, the refractive index values of sucrose and water solutions at different concentrations, which were used as a calibration method, were calculated to be (1.346, 1.359, 1.382, and 1.39). It was found that when the refractive index of the sensitive medium increases, the length of the resonant wavelength increases due to the decrease in energy.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Mar 01 2008
Journal Name
Iraqi Journal Of Physics
Influence of Gold Concentration on the Main Detection Parameters of Ge-Au Photoconductive Detector
...Show More Authors

Ge-Au infrared photoconductive detection was prepared from germanium single crystal which were doped with different gold concentration using thermal evaporation. The spectral resonsivity (Rλ), spectral detectivity (D*) were determined as function of wavelength, also the resistance, conductivity in dark and with illumination to infrared radiation, the gain and relative photo response have been measured with different gold concentration. Remarkable improvements in the photoresponse gain were observed for the highest resistance specimen at the expense of spectral detectivity values.

View Publication Preview PDF
Publication Date
Sun Aug 21 2022
Journal Name
International Journal Of Health Sciences
Molecular detection of fimH& mrkDgenes of strong biofilm producers & MDR Klebsiella pneumoniae
...Show More Authors

Klebsiella pneumoniae is an adaptable pathogen that forms biofilms on a variety of surfaces. This study's objective was to identify the presence of fimbrial genes (types 1 and 3) in K. pneumoniae strains isolated from various clinical sources based on their antibiotic resistance and ability to form biofilms. According to identification utilizing the vitek 2 technology and confirmation by molecular identification targeting the 16S rRNA gene with a particular primer, forty isolates were identified from clinical specimens. The vitek 2 compact system was utilized to evaluate the antibiotic susceptibility of all the isolates. The findings revealed a range of resistance percentages, including 52.5% for Penicillin, 40.5% for Trimethoprim/S

... Show More
View Publication
Crossref
Publication Date
Tue Jan 01 2013
Journal Name
Baghdad Science Journal
Detection of Type 2 Diabetes Mellitus in Serum from Women with Polycystic Ovarian Syndrome
...Show More Authors

Polycystic ovary syndrome (PCOS) is one of the most common endocrine disorder. To determine the metabolic disorders in women with PCOS, (25) women with PCOS ages (15 - 47) years have been investigated and compared with (20) healthy individuals. All the studied groups were carried out to measure fasting blood sugar, (anti-GAD Ab, anti β-islet cell Ab by IFAT) and measured insulin level by ELISA. There was significant elevation in the concentration of fasting blood sugar than in control groups (p ≤ 0.05) and there was negative results for anti-GAD Ab and anti β-islet cell Ab by IFAT test for serum of women with PCOS, while there was significant differences in the insulin level for women with PCOS compared with control groups (p ≤ 0.05),

... Show More
Publication Date
Tue Jan 05 2016
Journal Name
Iraqi Journal Of Science
Local Study of blaCTX-M genes detection in Proteus spp. by using PCR technique
...Show More Authors

n this study, 25 clinical isolates of Proteus spp. were collected from urine, wounds and burns specimens from different hospitals in Baghdad city, all isolates were identified by using different bacteriological media, biochemical assays and Vitek-2 system. It was found that 15 (60%) isolates were identifies as Proteus mirabilis and 10 (40 %) isolates were Proteus vulgaris. The susceptibility of P. mirabilis and P. vulgaris isolates towards cefotaxime was (66.6 %) and (44.4 %) respectively; while the susceptibility of P. mirabilis and P. vulgaris isolates towards ceftazidime was (20%). Extended spectrum β-lactamses producing Proteus was (30.7 %). DNA of 10 isolates of P. mirabilis and 4 isolates of P. vulgaris were extracted and de

... Show More
Publication Date
Thu Feb 01 2018
Journal Name
European Journal Of General Medicine
The Value of Longitudinal Strain versus Coronary Angiography in Detection of Coronary Artery Disease
...Show More Authors

Aims: The aim of this study was to evaluate the value and accuracy of longitudinal strain in detection of coronary artery disease compared to coronary angiography. Results: The left ventricular longitudinal strain-speckle tracking showed evidence of stenosis of left anterior descending artery, circumflex artery and right coronary artery in (86.1%), (76.4%), and (84.7%) respectively. For the stenosis in left anterior descending artery, the current study showed that the longitudinal strain was a good predictor for presence of significant stenosis with a sensitivity of (93.8%), specificity (75%) and accuracy (91.7%) compared with coronary angiography. For the stenosis in right coronary artery, the left ventricular longitudinal strain had

... Show More
View Publication
Crossref (2)
Crossref
Publication Date
Tue Nov 01 2022
Journal Name
Inorganic Chemistry Communications
Sarin chemical warfare agent detection by Sc-decorated XN nanotubes (X = Al or Ga)
...Show More Authors

In order to scrutinize the impact of the decoration of Sc upon the sensing performance of an XN nanotube (X = Al or Ga, and XNNT) in detecting sarin (SN), the density functionals M06-2X, τ-HCTHhyb, and B3LYP were utilized. The interaction of the pristine XNNT with SN was a physical adsorption with the sensing response (SR) of approximately 5.4. Decoration of the Sc metal into the surface of the AlN and GaN led to an increase in the adsorption energy of SN from −3.4 to −18.9, and −3.8 to −20.1 kcal/mol, respectively. Also, there was a significant increase in the corresponding SR to 38.0 and 100.5, the sensitivity of metal decorated XNNT (metal@XNNT) is increased. So, we found that Sc-decorating more increases the sensitivity of GaNN

... Show More
View Publication
Scopus (1)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Tue Sep 01 2020
Journal Name
Baghdad Science Journal
Developing Arabic License Plate Recognition System Using Artificial Neural Network and Canny Edge Detection
...Show More Authors

In recent years, there has been expanding development in the vehicular part and the number of vehicles moving on the roads in all the sections of the country. Arabic vehicle number plate identification based on image processing is a dynamic area of this work; this technique is used for security purposes such as tracking of stolen cars and access control to restricted areas. The License Plate Recognition System (LPRS) exploits a digital camera to capture vehicle plate numbers is used as input to the proposed recognition system. Basically, the proposed system consists of three phases, vehicle license plate localization, character segmentation, and character recognition, the License Plate (LP) detection is presented using canny edge detection

... Show More
Publication Date
Fri Jan 01 2016
Journal Name
World Journal Of Experimental Biosciences
Detection of anti-Helicobacter pylori antibodies in sera of women with recurrent spontaneous abortion
...Show More Authors

To determine the relationship between Helicobacter pylori infection and reproduction disorder (recurrent spontaneous abortion), twenty women patients who undergo spontaneous abortion during first trimester of pregnancy (20-38) years and have been investigated from 2015/12/1 -2016/3/1 and compared to fifteen healthy individuals. All subjects were carried out to measure anti-H. pylori IgA and anti- H. pylori IgG antibodies by enzyme linked immunosorbent assay (ELISA). There was significant elevation (p≤ 0.05) in concentration of anti- H. pylori IgG Abs (6.30± 0.99) compared to control group (4.48± 0.61) and IgA Abs (5.42 ± 0.90 U /ml) as compared to control group (3.92 ± 0.41 U/ml). The percentage of H. pylori IgG and IgA was 20% and 25

... Show More
Publication Date
Sun Mar 01 2020
Journal Name
Iraqi Journal Of Physics
Blood Vessels Detection of Diabetic Retinopathy from Retinal Fundus Image using Image Processing Techniques
...Show More Authors

 

Early detection of eye diseases can forestall visual deficiency and vision loss. There are several types of human eye diseases, for example, diabetic retinopathy, glaucoma, arteriosclerosis, and hypertension. Diabetic retinopathy (DR) which is brought about by diabetes causes the retinal vessels harmed and blood leakage in the retina. Retinal blood vessels have a huge job in the detection and treatment of different retinal diseases. Thus, retinal vasculature extraction is significant to help experts for the finding and treatment of systematic diseases. Accordingly, early detection and consequent treatment are fundamental for influenced patients to protect their vision. The aim of this paper is to detect blood vessels from

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Sat Oct 04 2025
Journal Name
Mesopotamian Journal Of Computer Science
Enhanced IOT Cyber-Attack Detection Using Grey Wolf Optimized Feature Selection and Adaptive SMOTE
...Show More Authors

The Internet of Things (IoT) has significantly transformed modern systems through extensive connectivity but has also concurrently introduced considerable cybersecurity risks. Traditional rule-based methods are becoming increasingly insufficient in the face of evolving cyber threats.  This study proposes an enhanced methodology utilizing a hybrid machine-learning framework for IoT cyber-attack detection. The framework integrates a Grey Wolf Optimizer (GWO) for optimal feature selection, a customized synthetic minority oversampling technique (SMOTE) for data balancing, and a systematic approach to hyperparameter tuning of ensemble algorithms: Random Forest (RF), XGBoost, and CatBoost. Evaluations on the RT-IoT2022 dataset demonstrat

... Show More
View Publication Preview PDF
Crossref