Preferred Language
Articles
/
ijl-86
Human Skin WoundWelding Using 980 nm Diode Laser: an in Vitro Experimental Study
...Show More Authors

Laser assisted skin wound closure offers many distinct advantages over conventional closure
techniques. The objective of this in vitro experimental study, carried out at the Institute of Laser for
Postgraduate Studies/Baghdad University, was to determine the effectiveness of 980 nm diode laser in
welding of human skin wounds. Multiple 3-4 cm long full thickness incisions in a specimen of human
skin obtained from the discarded panniculus of an Abdominoplasty operation were tried to be laser
welded using a 4 mm spot diameter laser beam from a 980 nm diode laser at different laser parameters
and modes of action. The tensile strength at the weld site was analyzed experimentally. Although laser
assisted wound welding did actually happen at many laser parameter settings, it was not strong enough to
be clinically useful in living human beings. Despite the 980-nm diode laser system has proved to be an
effective way of wound welding but it the weld was of low tensile strength to withstand living patient
normal daily activity and movement. It can really shorten the operative time required to close a wound if
proper laser parameters were used among an endless effective combinations of parameters. Further future
studies are highly recommended on live human beings

View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Jun 17 2022
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Lornoxicam-Loaded Cubosomes: - Preparation and In vitro Characterization.
...Show More Authors

Cubosomes are nanosized structures self-assembled nanostructured materials used for controlling the release of the entrapped drug molecule. Lornoxicam (LXM) is a potent analgesic nonsteroidal anti-inflammatory (NSAID) drug with a short half-life (3-4) hours. The present study aims to prepare LXM-loaded cubosomes with well-defined morphology, particle size, PDI, high entrapment efficiency, sustained drug release, and high zeta potential value, as a transdermal drug delivery system.

      Twelve formulas of LXM-loaded cubosomal dispersions were prepared by a solvent dilution method using Glyceryl monooleate ( GMO) as polar lipid with different stabilizers as Pluronic® F127 or tween 80 and different types o

... Show More
View Publication Preview PDF
Scopus (25)
Crossref (6)
Scopus Crossref
Publication Date
Tue Jun 15 2021
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Microneedle Array Patches: Characterization and in -vitro Evaluation
...Show More Authors

 Patch in transdermal drug delivery(TDDS) used to overcome the hypodermic drawback, but these patch also have absorption limitation for hydrophilic and macromolecule like peptide and DNA. So that micronized projection have the ability for skin penetration developed named as microneedle.  Microneedle drug delivery system is a novel drug delivery to overcome the limitation of TDDS like skin barrier restriction for large molecule. Microneedle patch can penetrate through skin subcutaneous into epidermis, avoiding nerve fiber and blood vessel contact. There are many type of microneedle patch like solid, polymer, hallow, hydrogel forming microneedle and dissolving microneedle with different method of microfabrication

View Publication Preview PDF
Scopus (5)
Crossref (3)
Scopus Crossref
Publication Date
Wed Mar 29 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
In vitro Evaluation of Tinidazole Bioadhesive Vaginal Gels
...Show More Authors

         Many trials were made to prepare Tinidazole 2% as bioadhesive vaginal gels using different gel bases including hydroxypropyl methyl cellulose (3 and 4% w/w), methylcellulose (3 and 4%w/w) and    carboxymethylcellulose (2 and 3% w/w) .Swelling index of the polymers,pH , viscosity , bioadhesive force , and in-vitro drug release to the simulating vaginal fluid (S.V.F.) were investigated for all the prepared bioadhesive gels . The mechanism of drug release from the gel bases was also investigated.

The results revealed that C MC 3% gave the highest viscosity and bioadhesive strength with the lowest release rate while lowest viscosity and bioadhesive force

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Tue Dec 01 2020
Journal Name
Baghdad Science Journal
Optimization of Voltammetric Determination of Dysprosium (III) Using Plackett-Burman and RSM-CCD Experimental Designs
...Show More Authors

This study was aimed to develop an optimized Dy determination method using differential pulse voltammetry (DPV). The Plackett-Burman (PB) experimental design was used to select significant factors that affect the electrical current response, which were further optimized using the response surface method-central composite design (RSM-CCD). The type of electrolyte solution and amplitude modulation were found as two most significant factors, among the nine factors tested, which enhance the current response based on PB design. Further optimization using RSM-CCD shows that the optimum values for the tw

... Show More
View Publication Preview PDF
Scopus (7)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Sat Jul 28 2018
Journal Name
Journal Of Engineering
Experimental Investigation for the Removal of Toxic Gases from Vehicle Exhaust using Non-Thermal Plasma
...Show More Authors

In this study, the use of non-thermal plasma theory to remove toxic gases emitted from a vehicle was experimentally investigated. A non-thermal plasma reactor was constructed in the form of a cylindrical tube made of Pyrex glass. Two stainless steel rods were placed inside the tube to generate electric discharge and plasma condition, by connecting with a high voltage power supply (up to 40 kV). The reactor was used to remove the contaminants of a 1.25-liter 4-cylinder engine at ambient conditions. Several tests have been carried out for a ranging speed from 750 to 4,500 rpm of the engine and varying voltages from 0 to 32 kV. The gases entering the reactor were examined by a gas analyzer and the gases concentration ratio

... Show More
View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Fri Nov 02 2018
Journal Name
Iraqi National Journal Of Nursing Specialties
Evaluation of Nursing Knowledge and Practices Concerning Nursing Care of Patient with Skin Traction in Orthopedic Units in Kurdistan Region
...Show More Authors

Objective: The study aimed to evaluate knowledge and practices of nursing staff at the orthopedic units
regarding the existing care of patient with skin traction.
Methodology: The sample consists of (40) nurses, (20) of them from Emergency Teaching Hospital in Duhok
and the other (20) of them from Erbil Teaching Hospital in Erbil from 1st Dec. 2004 to the end of June 2005 in
Kurdistan Region.
Two instruments were constructed to evaluate knowledge and practices. Evaluation of knowledge was done by
using of multiple choice questions composed of (25) questions, and evaluation of practice was done by using the
observational check list which consist of four main category (pre skin traction, during skin traction, post skin

... Show More
View Publication Preview PDF
Publication Date
Sun Nov 01 2020
Journal Name
Am J Clin Res Rev
Clinical and histopathological findings in patients with follicular dermatoses: all skin diseases starts in the hair follicles as new hypothesis
...Show More Authors

KE Sharquie, AA Noaimi, RA Flayih, Am J Clin Res Rev, 2020 - Cited by 4

View Publication
Publication Date
Tue May 20 2025
Journal Name
Vrsacin Deae-cellulose Linezolid Neutrophils Inflammation
Antibacterial and therapeutic effects of vancomycin-resistant Staphylococcus aureus bacteriocin (VRSAcin) in the treatment of VRSA skin infection in mice
...Show More Authors

Vancomycin Staphylococcus aureus (VRSA) is a strain of S. aureus that is considered the main cause of bacterial skin and soft tissue infections. It has acquired resistance to vancomycin and represents a therapeutic challenge. The current study aimed to compare the possible therapeutic effects of VRSA bacteriocin (VRSAcin) on the treatment of skin infection in mice with those of an antibiotic (linezolid). The results showed that of the fifty swabs obtained from human skin wounds. One isolate was selected for VRSAcin extraction depending on its antibiotic resistance using an antibiotic susceptibility test.An agar well diffusion test was used to determine bacteriocin’s antibacterial activity, as well as its a minimum inhibitory concentration

... Show More
Preview PDF
Publication Date
Fri Aug 01 2025
Journal Name
Microbial Pathogenesis
Antibacterial and therapeutic effects of vancomycin-resistant Staphylococcus aureus bacteriocin (VRSAcin) in the treatment of VRSA skin infection in mice
...Show More Authors

View Publication
Scopus (5)
Crossref (4)
Scopus Crossref
Publication Date
Sat Dec 31 2022
Journal Name
Mathematical Modelling Of Engineering Problems
Experimental and Numerical Study of Open Channel Flow with T-Section Artificial Bed Roughness
...Show More Authors

Experimental and numerical studies have been conducted on the effects of bed roughness elements such as cubic and T-section elements that are regularly half-channel arrayed on one side of the river on turbulent flow characteristics and bed erosion downstream of the roughness elements. The experimental study has been done for two types of bed roughness elements (cubic and T-section shape) to study the effect of these elements on the velocity profile downstream the elements with respect to different water flow discharges and water depths. A comparison between the cubic and T-section artificial bed roughness showed that the velocity profile downstream the T-section increased in smooth side from the river and decrease in the rough side

... Show More
View Publication
Scopus (1)
Scopus Crossref