The electro-optic coefficient r63 and r41 are determined in congruent KDP crystals, using an experimental method based upon the direct measurement of material. Sénarmont system for electro-optic coefficient measurement and characterization of crystals was modified. This modification allowed us to obtain on the frequency dispersion dependence of the electro-optic coefficients within a frequency range up to 20 MHz and on a new version of modulation depth method. To the best of our knowledge, by using this system, the electro-optic coefficients r63 and r41 in different configurations (transverse and longitudinal) have been measured for the first time within a frequency range up to 20 MHz. The measurements have been investigated as a function of laser wavelength ranging from 532 nm to 750 nm. While previously these coefficients where measured at only one wavelength, 632.8 nm, and the unclamped coefficient r63 is known at just 3390 nm. From these measurements, the clamped and unclamped electro-optic coefficients as well as the acoustic contribution have been determined
The principle of rights and duties is part of the reform project of the Commander of the Faithful Ali ibn Abi Talib, to build a state of institutions whose foundations have been built on Quranic rules, a prophetic biography, and his diligence in doing so in accordance with the requirements of interests and evil, and his certainty in determining the most important and important, and research analytical study of speeches Imam Ali and his career, in this study (the principle of rights and duties) of the ruler and the parish because of their role in the reform process, which depends on the demolition and construction together, as it is the responsibility of the ruler to demolish all constructed corrupt and contrary to the principles of Islam
... Show MoreAn optical video communication system is designed and constructed using pulse frequency modulation (PFM) technique. In this work PFM pulses are generated at the transmitter using voltage control oscillator (VCO) of width 50 ns for each pulse. Double frequency, equal width and narrow pulses are produced in the receiver be for demodulation. The use of the frequency doubling technique in such a system results in a narrow transmission bandwidth (25 ns) and high receiver sensitivity.
Background: Recent implant surgical approach aims to cause less trauma, invasiveness and pain as much as possible and to reduce patient and surgeon discomfort, time of surgery and time needed for functional implant loading. Flapless surgical techniques considered recently as one of the most popular techniques that may achieve these aims especially enhancing osseointegration and subsequently implant stability within less time than the traditional flapped surgical technique. So this study aimed to make a comparison between flapped and flapless surgical techniques in resulted implant stability according to resonance frequency analysis RFA and in duration of surgical operation. Materials and methods: A total of 26 patients with 41 implants (o
... Show MoreBackground: The genetic polymorphisms of vitamin D receptor (VDR) have an association with thalassemia development, additionally to the environmental elements that elicited the disorder in the genetically predisposed individuals. As well, VDR functions responsible for the regulation of bone metabolism, such its part in immunity. Aim: The sitting study intended to inspect the association between thalassemia disease and the genetic polymorphisms of VDR among the Iraqi population then compared these findings to other findings of thalassemia patients in other different ethnic populations. Materials and methods: The restriction enzymes Bsm-I and Fok-I were applied to determine the genetic polymorphisms frequencies of VDR by a Polymerase Chain Re
... Show MoreThe relation between the output power and wavelengths for a 532nm 3W frequency doubled diode pumped solid state laser pumped Ti:Sapphire crystal is investigated. A 20 femtosecond pulse at 800 nm is obtained. A 320 mW is found to be the highest power at 800nm. Below this wavelength value and above the power was found to deviate from highest output value.
Background: For many decades, the ECG was the
workhorse of non-invasive cardiac test and today although
other techniques provide more details about the structural
anomalies in congenital heart diseases, ECG is likely to be
part of clinical evaluation of patients with such diseases
because it is inexpensive, easy to perform and in certain
situations may be both sensitive and specific.
Objective: this study carried out to identify the pattern of
ECG study in patients with TOF.
Methods: this is a retrospective study of 200 patients
with TOF, referred to Ibn Al-Bitar cardiac center from
April 1993 to May 1999. The diagnosis of TOF established
by echocrdiographic, catheterization and angiographic
study.