The electro-optic coefficient r63 and r41 are determined in congruent KDP crystals, using an experimental method based upon the direct measurement of material. Sénarmont system for electro-optic coefficient measurement and characterization of crystals was modified. This modification allowed us to obtain on the frequency dispersion dependence of the electro-optic coefficients within a frequency range up to 20 MHz and on a new version of modulation depth method. To the best of our knowledge, by using this system, the electro-optic coefficients r63 and r41 in different configurations (transverse and longitudinal) have been measured for the first time within a frequency range up to 20 MHz. The measurements have been investigated as a function of laser wavelength ranging from 532 nm to 750 nm. While previously these coefficients where measured at only one wavelength, 632.8 nm, and the unclamped coefficient r63 is known at just 3390 nm. From these measurements, the clamped and unclamped electro-optic coefficients as well as the acoustic contribution have been determined
This paper comprises the design and operation of mono-static backscatter lidar station based on a pulsed Nd: YAG laser that operates at multiple wavelengths. The three-color lidar laser transmitter is based on the collinear fundamental 1064 nm, second harmonic 532 nm and a third harmonic 355nm output of a Nd:YAG laser. The most important parameter of lidar especially daytime operations is the signal-to-noise ratio (SNR) which gives some instructions in designing of lidar and it is often limit the effective range. The reason is that noises or interferences always badly affect the measured results. The inversion algorithms have been developed for the study of atmospheric aerosols. Signal-to-noise ratio (SNR) of three-color channel re
... Show MoreObjective: The study aims at assessing the food frequency intake and dietary habits for diabetic pregnant
women.
Methodology: A descriptive study is carried out for the period from November4th 2013 to August
25th 2014. A purposive "non-probability" sample of one hundred diabetic pregnant women is selected from
the Diabetic and Endocrine Center in Al-Amarha City. A questionnaire is developed as a tool of data
collection. Content validity of the study instrument is determined through panel of experts. Split-half
reliability technique is used for reliability determination of the study instrument which depicts a reliability
coefficient of (0.79) for the entire scale. A structured interview with each diabetic pregnant wom
Abstract:
Saudi Arabia and United States long relation could present an important
subject to understand alliance kind in international relations types. We trying
in this study to diagnose and analyze the Saudi Arabia and United States
model to find balance and unbalance statues and its influence on the
directions of Saudi Arabia foreign policy positions.
We divided the study in two parts, each part have many sections. The
first part deal with the historian emergence of Saudi Arabia state and its
development in three stages including its foreign relations with regions and
international powers. While the second part was dedicated in analyzing and
understanding the mechanism and active facts that drawing the Sa
BACKGROUND: CRC is one of the most common cancers in the world. K-ras is proto-oncogene with GTPase activity that is lost when the gene is mutated. Analysis of K-ras mutational status is very important for CRC treatment, being the most important predictors of resistance to targeted therapy. OBJECTIVE: This study aims to determine the frequency and spectrum of K-ras mutation among Iraqi patients with sporadic CRC. PATIENTS, MATERIALS AND METHODS: This study enrolled 35 cases with sporadic CRC; their clinicopathological parameters were analyzed. The FFPE blocks were used for DNA extraction; PCR amplification of K-ras gene and hybridization of allele-specific oligoprobes were performed. The assay covers 29 mutations in the K-ras gene (codons 1
... Show MoreThe influence of 5-10 kHz audio frequency on the power dissipation in ac discharge of argon gas was studied experimentally, at pressures 50-80 mTorr and electrodes separation 10 cm (pd range 0.5-0.8 Torr.
cm). The measurements have shown that the discharge behavior in the ac circuit is equivalent to a series RC circuit. It is observed that the variation curve of discharge power P with the frequency f is approximately has a Gaussian shape. It is also observed that the curve of Pm- pd is the inverse of Paschen curve, where Pm is the maximum power in the frequency range. The time of breakdown is estimated from the curve of P- f.
Internal conversion coefficients (ICC) and electron–positron pair conversion coefficients (PCC) for multipole transition of the core nucleus 88Sr have been calculated theoretically. The calculation is based on the relativistic Dirac–Fock (DF) solutions using the so called ‘‘Frozen Orbital’’ approximation, takes into account the effect of atomic vacancies created in the conversion process, covering a transition energies of 1–5000 keV. A large number of points were used to minimize any errors due to mesh-size effects. The internal conversion coefficients display a smooth monotonic dependence on transition energy, multipolarity and atomic shell. Comparing the values of PCC to ICC, it is interesting to note, that the energy dep
... Show MoreIn this study, we focused on the random coefficient estimation of the general regression and Swamy models of panel data. By using this type of data, the data give a better chance of obtaining a better method and better indicators. Entropy's methods have been used to estimate random coefficients for the general regression and Swamy of the panel data which were presented in two ways: the first represents the maximum dual Entropy and the second is general maximum Entropy in which a comparison between them have been done by using simulation to choose the optimal methods.
The results have been compared by using mean squares error and mean absolute percentage error to different cases in term of correlation valu
... Show MoreIn the present work, different thicknesses of CdS film were prepared by chemical bath deposition. Z-Scan technique was used to study the nonlinear refractive index and nonlinear absorption coefficients. Linear optical testing were done such as transmission test, and thickness of films were done by the interference fringes (Michelson interferometer). Z-scan experiment was performed at 650nm using CW diode laser and at 532nm wavelength. The results show the effect of self-focusing and defocusing that corresponds with nonlinear refraction n2. The effect of two-photon absorption was also studied, which correspond to the nonlinear absorption coefficient B.
In this paper, we propose a new and efficient ferroelectric nanostructure metal oxide lithium niobate [(Li1.075Nb0.625Ti0.45O3), (LNTO)] solid film as a saturable absorber (SA) for modulating passive Q-switched erbium-doped fiber laser (EDFL). The SA is fabricated as a nanocomposite solid film by the drop-casting process in which the LNTO is planted within polyvinylidene fluoride-trifluoroethylene [P(VDF-TrFE)] as host copolymer. The optical and physical characteristics of the solid film are experimentally established. The SA is incorporated within the cavity of EDFL to examine its capability for producing multi-wavelength laser. The experimental results proved that a multi-wavelength laser is produced, where stable four lines with central
... Show More