The Efficacy of (810 Nm) Diode Laser in Treatment of Idiopathic Epistaxis
...Show More Authors

There are many causes for epistaxis but it is mainly idiopathic in type. In Management of epistaxis there are different modality either medical or cautery(chemical or galvanic) recently laser is used in management of epistaxis. The type of laser used in current study was 810 nm diode laser. The aim of the study is to evaluate its efficiency in control of active and non active idiopathic epistaxis; The design of the study is interventional therapeutic trial. The study was performed from December 2011 to December 2012 in Al Yarmouk teaching hospital at otorhinolaryngology department. In current study the diode laser is used in different power with same exposure time in all application; The power density is measured and choose the best one to stop both active and non active bleeding. The modality is compared with galvanic electrical cautery used in treatment of epistaxis. the comparison depends on the side effect and the complication of each modality.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Sep 01 2023
Journal Name
Journal Of Environmental Management
Treatment of vegetable oil refinery wastewater by sequential electrocoagulation-electrooxidation process
...Show More Authors

View Publication
Scopus (12)
Crossref (13)
Scopus Clarivate Crossref
Publication Date
Tue Dec 13 2011
Journal Name
Iraqi Journal Of Laser
Intra Cellular Fluorescence for Monitoring The Physiological Changes and Biostimulation of Yeast Irradiated with Low Power 532nm CW Nd:YAG Laser
...Show More Authors

The purpose of this study is to investigate the biostimulation effect of 532 nm CW laser on the metabolism of Saccharomyces cerevisiae yeast. Cells were irradiated by 532 nm Nd:YAG laser using 0.153 W/cm2 power density at 30, 45, 60,180 and 300 seconds exposure times in their respective orders. Intrafluorescence parameters were measured by detection the autofluorescence intensity, proliferation rate and Imaging the fluorescent mitochondria using confocal laser scanning microscope. The results showed that the 30 and 45 second exposure times seem to have stimulated changes in the cells that led to increase proliferation, viability and mitochondrial activity. Autofluorescence of cells increased after 45 and 60 seconds exposure time. After 3

... Show More
View Publication Preview PDF
Publication Date
Mon Nov 01 2010
Journal Name
Iraqi Journal Of Physics
Preparation of Xerogel Films Doped with R6G Laser Dye using spin coating technique and Study the Spinning parameters Baha T.
...Show More Authors

Spin coating technique has been applied in this work to prepared Xerogel films doped with Rhodamine 6G laser dyes. The solid host of laser dye modifies its spectroscopic properties with respect to liquid host. During the spin coating process the dye molecules suffer from changing their environment. The effects of three parameters were studied here: the spinning speed, multilayer coating and formaldehyde addition

View Publication Preview PDF
Publication Date
Sun Nov 01 2020
Journal Name
Journal Of Physics: Conference Series
Laser Irradiation Effect on The Optical Properties of CoO<sub>2</sub>Thin Films deposited via Semi-Computerized Spraying System
...Show More Authors
Abstract<p>In this paper deals with the effect laser irradiation on the optical properties of cobalt oxide (CoO<sub>2</sub>) thin films and that was prepared using semi computerized spray pyrolysis technique. The films deposited on glass substrate using such as an ideal value concentration of (0.02)M with a total volume of 100 ml. With substrate temperature was (350 C), spray rate (15 ml/min).The XRD diffraction given polycrystalline nature with Crystal system trigonal (hexagonal axes). The obtained films were irradiated by continuous green laser (532.8 nm) with power 140 mW for different time periods is 10 min,20min and 30min. The result was that the optical properties of cobalt oxide thin films affe</p> ... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Thu Oct 02 2025
Journal Name
Journal Of Baghdad College Of Dentistry
The effect of waterlase laser and herbal alternative, green tea and Salvadora Persica (Siwak) extract on push-out bond strength
...Show More Authors

Background: The bond strength of root canal sealers to dentin was important for maintaining the integrity of the seal in root canal filling in both static and dynamic situations. In a static situation, it should eliminate any space that allowed the percolation of fluids between the filling and the wall while in a dynamic situation; it was needed to resist dislodgement of the filling during subsequent manipulation. Materials and Methods: Forty mandibular premolars were selected for this study. All canals were instrumented using ProTaper rotary instruments. Instrumentation was done with copious irrigation of 5.25% sodium hypochlorite. Roots were randomly divided into four groups according to the type of cleaning and method of root canal irrig

... Show More
View Publication Preview PDF
Publication Date
Sat Jan 01 2022
Journal Name
Geotechnical Engineering And Sustainable Construction
Determine the Most Common Geotechnical Risks and Their Impacts on the Cost and Time Schedule for Implementing Water Treatment Plants in Iraq
...Show More Authors

View Publication
Crossref
Publication Date
Wed Jun 30 2010
Journal Name
Al-kindy College Medical Journal
Is co2 laser Hemorrhoidectomy superior to conventional open Hemorrhoidectomy?
...Show More Authors

Background: Hemorrhoids are one of the most
common surgical conditions .Conventional
haemorrhoidectomy was the traditional operation for
the treatment of hemorrhoids. Other modalities of
treatment had been used as an alternative operations
including CO2 laser haemorrhoidectomy.
Objectives: To determine the outcome of treatment
of hemorrhoids by using CO2 laser
haemorrhoidectomy and its advantages over
conventional surgery
Methods: This is a retrospective comparative
interventional study of 1024 case of third degree
haemorhoids selected out of 1300 case of
hemorrhoids of different degrees, admitted to
ALKINDY, ALYERMOUK teaching hospitals and
ABD ALMAGEED private hospital, from May 1998
to J

... Show More
View Publication Preview PDF
Publication Date
Mon Jun 12 2006
Journal Name
Iraqi Journal Of Laser
Laser-Induced Low-Resistance Ohmic Contacts on n-Si
...Show More Authors

In the present work, the feasibility of formation near-ideal ohmic behavior of In/n-Si contact efficiently by 300 s duration Nd:YAG pulsed laser processing has been recognized. Several laser pulses energy densities have been used, and the optimal energy density that gives best results is obtained. Topography of the irradiated region was extensively discussed and supported with micrographic illustrations to determine the surface condition that can play the important role in the ohmic contact quality. I-V characteristics in the forward and reverse bias and barrier height measurements have been studied for different irradiated samples to determine the laser energy density that gives best ohmic behavior. Comparing the current results with

... Show More
View Publication Preview PDF
Publication Date
Wed Jun 10 2009
Journal Name
Iraqi Journal Of Laser
A new achromatic glass for near infrared laser instruments
...Show More Authors

This research investigates new glasses which are best suitable for design of optical systems
working in the infrared region between 1.01 to 2.3μm. This work is extended to Oliva & Gennari
(1995,1998) research in which they found that the best known achromatic pairs are (BAF2-IRG2; SRF2-
IRG3; BAF2-IRG7; CAF2-IRGN6; BAF2-SF56A and BAF2-SF6). Schott will most probably stop the
production of these very little used and commercially uninteresting IRG glasses. In this work equally
good performances can be obtained by coupling BAF2, SRF2&CAF2 with standard glasses from Schott
or Ohara Company. The best new achromatic pairs found are (SRF2-S-TIH10; CAF2-S-LAL9; CAF2-SLAL13
and CAF2-S-BAH27). These new achromatic pai

... Show More
View Publication Preview PDF
Publication Date
Mon Nov 01 2010
Journal Name
Iraqi Journal Of Physics
Night Vision monitor for IR laser spot size Identification
...Show More Authors

The aim of this research is to design and construct a
semiconductor laser range finder operating in the near infrared range
for ranging and designation. The main part of the range finder is the
transmitter which is a semiconductor laser type GaAs of wavelength
0.904 μm with a beam expander and the receiver; a silicon pin
detector biased to approve the fast response time with it's collecting
optics. The transmitters pulse width was 200ns at a threshold current
of 10 Ampere and maximum operating current of 38 Ampere. The
repetition rate was set at 660Hz and the maximum operating output
power was around 1 watt. The divergence of the beam was 0.268o
the efficiency of the laser was 0.03% at a duty cycle of 1.32x

... Show More