In the present work, heterojunction diode detectors will be prepared using germanium wafers as a substrate material and 200 nm tin sulfide thickness will be evaporated by using thermal evaporation method as thin film on the substrate. Nd:YAG laser (λ=532 nm) with different energy densities (5.66 J/cm2 and 11.32 J/cm2) is used to diffuse the SnS inside the surface of the germanium samples with 10 laser shots in different environments (vacuum and distilled water). I-V characteristics in the dark illumination, C-V characteristics, transmission measurements, spectral responsivity and quantum efficiency were investigated at 300K. The C-V measurements have shown that the heterojunction were of abrupt type and the maximum value of build-in potential is equal to 1.78V in water environment .The results showed that the detectors have two peaks at 900 nm and 1250 nm and the maximum spectral responsivity can be obtained at λ=1250 nm in water environment. Also the quantum efficiency has two peaks at 900nm and 1250 nm and it is increase the increase in laser energy density and this increase is to be clear in the water environment more than the vacuum environment.
Wireless Body Area Sensor Networks (WBASNs) have garnered significant attention due to the implementation of self-automaton and modern technologies. Within the healthcare WBASN, certain sensed data hold greater significance than others in light of their critical aspect. Such vital data must be given within a specified time frame. Data loss and delay could not be tolerated in such types of systems. Intelligent algorithms are distinguished by their superior ability to interact with various data systems. Machine learning methods can analyze the gathered data and uncover previously unknown patterns and information. These approaches can also diagnose and notify critical conditions in patients under monitoring. This study implements two s
... Show More
This paper investigates the interaction between fiscal and monetary policy in Iraq after 2003 using the prisoner’s dilemma.The paper aims to determine the best form of coordination between these policies to achieve their goals; payoff matrix for both policies was constructed. To achieve the purpose, the quantitative approach was applied using several methods, including regression, building payoff matrices and decision analysis using a number of software.The results of the monetary policy payment function show that inflation rate has an inverse relationship with the auctions of selling foreign currency and a positive relationship with the government’s activity, while the fiscal policy function shows that real growth is positively
... Show More
In this paper, effective slab width for the composite beams is investigated with special emphasis on the effect of web openings. A three dimensional finite element analysis, by using finite element code ANSYS, is employed to investigate shear lag phenomenon and the resulting effective slab width adopted in the classical T-beam approach. According to case studies and comparison with limitations and rules stipulated by different standards and codes of practice it is found that web openings presence and panel proportion are the most critical factors affecting effective slab width, whereas concrete slab thickness and steel beam depth are less significant. The presence of web opening reduces effective slab width by about 21%.
... Show MoreType 2 diabetes mellitus (T2DM) is the most frequent endocrinal disease commonly associated with thyroid disorders .The study is conducted at the Specialized Center for Endocrinology and Diabetes in Baghdad ,during December 2014 up to October 2015.This study was done to investigate the prevalence of anti- thyroid peroxidase (Anti-TPO) antibody in patients suffered from type 2 diabetes with thyroid disorders .The study groups included a total number of 80 subjects consisting of 60 type 2 diabetic patients divided into 20 hyperthyroidism subjects (group 1) ,20 hypothyroidism subjects (group 2), 20 euthyroidism subjects (group 3) and 20 healthy controls (group 4) . The fasting blood samples were analyzed for (T3,T4,TSH) by using Vitek Immuno d
... Show MoreRadiation measuring devices need to periodic calibration process to examine their sensitivity and the extent of the response. This study is used to evaluate the radiation doses of the workers in the laboratories of the Directorate of Safety as a result of the use of point sources in calibrating of the devices in two ways, the first is the direct measurement by the FAG device and the others using RESRAD and RAD PRO programs. The total doses values using FAG were (2.57 μSv/y, 102.3 μSv/y and 20.75 μSv/y for TLD laboratory, Gamma spectroscopy analyses (GSA) laboratory and equipment store respectively, and the total doses that calculated using RESRAD and RAD PRO were 1.518 μSv/y, 76.65 μSv/y and 21.2 μSv/y for the above laboratories. t
... Show More