Laser etching may be an alternative to acid etching of enamel and dentin. Several characteristics of irradiated dental hard tissues have been considered advantageous, microscopically rough surfaces without demineralization, open dentinal tubules without smear layer production and dentin surface sterilization. The aim of this study is to determine and compare histology the microleakage in class V cavity restored with a light cured composite after conditioning the samples(tooth surface) with 1-acid etching, 2-Q-switched Nd:YAG Laser etching and finally 3- acid and laser etching. Materials and methods: Twenty four non carious human extracted teeth were used in this study. The samples were equally grouped into four groups of six teeth each. A class V cavity was prepared. In group I, tooth surface was etched with a 37% phosphoric acid gel. In group II, the tooth surface was conditioned using a pulsed Nd:YAG Laser alone with a wavelength of 532 nm. The parameters were of pulse energy 60 mJ, pulse repetition rate 6Hz and energy density was 0.48 J/cm2. In group III, the tooth surface was treated with Nd: YAG Laser and then was etched with phosphoric acid. In group IV, the surface was treated with 37% phosphoric acid then irradiated with Nd: YAG Laser; with the same parameters and concentration mentioned in group I and II. The samples immersed in 1% basic fuschin dye to mimic the normal stains in oral cavity and the sections were examined by a stereomicroscope and the readings were scored. Results: The results showed that group IV, in which the surface was treated with 37% phosphoric acid and then irradiated with Nd: YAG Laser) recorded the least microleakage of the four groups, where group III, in which the tooth surface was treated with Nd: YAG Laser and then was etched with phosphoric acid)recorded reasonable results better than group I (group I tooth surface was etched with a 37% phosphoric acid gel) or group II , in which the tooth surface was conditioned using a pulsed Nd:YAG Laser alone) Conclusion: The use of Q-switched Nd:YAG laser in etching the tooth surface was so effective that it can be used in treating or conditioning the tooth surface to enhance bonding and the best parameters among the tested samples were pulse energy of 60mJ, pulse repetition rate of 6Hz and energy density 0.48 J/cm2.
In this study, doped thin cadmium peroxide films were prepared by pulsed laser deposition with different doping concentrations of aluminium of 0.0, 0.1, 0.3, and 0.5 wt.% for CdO2(1-X)Al(X) and thicknesses in the range of 200 nm. XRD patterns suggest the presence of cubic CdO2 and the texture factor confirms that the (111) plane was the preferential growth plane, where the texture factor and the grain size decreased from 2.02 to 9.75 nm, respectively, in the pure sample to 1.88 and 5.65 nm, respectively, at a concentration of 0.5 wt%. For the predominant growth plane, the deviation of the diffraction angle Δθ and interplanar distance Δd from the standard magnitudes was 2.774° and 0.318 Å, respectively, for the pure sample decreased to
... Show MoreTo produce Zinc Oxide NanoParticles, ZnO-NPs, different methods can be used. However, the utilization of Liquid-Phase Pulsed Laser Ablation, LP-PLA, methodology of three distinct environment of aqueous using pure zinc plate will be one of the approaches for this job. Thus, in this work, concentrates on the influence of the results after employing some changes on the environment in other words, the influence of the NPs size and/or the NPs availability/appearance. Cetyltrimethylammonium Bromide, CTAB, is one of the three surfactants that have been used in the water-based solution. That is, the Sodium Dodecyl Sulfate, SDS, besides the Distilled Water, DW, the three surfactants will be ready when the molarity of the DW is around 10− 3 M. Th
... Show MoreThe triggering effect for the face pumping of Nd:YVO4 disc medium of 4×5×0.5 mm was investigated using bulk diode laser at different resonator cavity length in pulse mode and at repetition rate of 1.3kHz. The maximum emitted peak power was found to be 100, 82, and 66 mW for resonator lengths of 10, 13.5, and 17.5 cm respectively, while the threshold pumping power was found to be 41mW. The maximum emitted peak power obtained was 300 mW when using external triggering and 10cm length, with repetition of 3Hz.
Temporomandibular Disorders (TMD) refer to a group of symptoms where pain is the most leading cause to demand a treatment by the patient. Light therapies are of great importance at current times due to its biosafety and non-invasive quality when used for the management of TMD symptoms. This study aimed to evaluate the efficacy of red LED light with low-level LASER in treating TMD patients.
A double-blind randomized clinical study was conducted and included 60 patients along 3 groups (20 for e
Abstract
The present paper attempts to detect the level of (COVID-19) pandemic panic attacks among university students, according to gender and stage variables.
To achieve this objective, the present paper adopts the scale set up by (Fathallah et al., 2021), which has been applied electronically to a previous cross-cultural sample consisting of (2285) participants from Arab countries, including Iraq. The scale includes, in its final form, (69) optional items distributed on (6) dimensions: physical symptoms (13) items, psychological and emotional symptoms (12) items, cognitive and mental symptoms (11) items, social symptoms (8) items, general symptoms (13) items and daily living practices (12) items
... Show MoreObjective(s): To assess the adequacy of mediation program on medical attendants practice toward care of kids with diabetic's ketoacidosis. Methodology: A quasi-experimental design that applied at teaching hospitals for pediatric in AL Ramadi city to establish the Effectiveness of Intervention Program on Nurses` Practices about Care of Children with Diabetic Ketoacidosis from 3th of March 2022 till 20 of March 2023. Non-probability (purposive) sample of (50), likewise was alienated into the study (experimental) group. The study group included (50) nurses non-randomly selected from AL-Ramadi Teaching Hospital.
A preliminary study has conducted in AL-Ramadi Teaching Hospital The whole number of nurse
... Show MoreA mathematical model is developed which predicates the performance of cylindrical ion exchange bed involving comparing of axial dispersion model for cation exchange column with different assumption, this model permits the performance to predicate the residence time within the bed with the variance, axial dispersion and Pecklet No. to indicated deviation from plug flow model.
Two type of systems are chosen for positive ions first with divalent ions (Ca+2) to exchange with resin of Na+1form used as application in water softener units and second with monovalent ions (Na+1) to exchange with resin of H+1 form used as application in deionize water units &n
... Show MoreThe goal of this study was to investigate the protein peroxidation role by measuring serum levels of advanced oxidation protein products (AOPP) in type 2 diabetic patients with or without retinopathy and comparing them to controls to see if circulating AOPP levels can be used as a detection biomarker for DR. And see which of the two widely used antidiabetic treatment groups had the most impact on this oxidative stress marker. The groups were divided into two subgroups: 1) 70 type 2 diabetic patients (36 male, 34 female), 35 with diabetic retinopathy (DR) and 35 with no evidence of DR, and 2) non-diabetic controls (11 male, 9 female) were chosen from Ibn AL-Haitham Hospital for Ophthalmology and a Specialized Center for Endocrinology and Dia
... Show MoreActivation of farnesoid X receptor (FXR) markedly attenuates development of atherosclerosis in animal models. However, the underlying mechanism is not well elucidated. Here, we show that the FXR agonist, obeticholic acid (OCA), increases fecal cholesterol excretion and macrophage reverse cholesterol transport (RCT) dependent on activation of hepatic FXR. OCA does not increase biliary cholesterol secretion, but inhibits intestinal cholesterol absorption. OCA markedly inhibits hepatic cholesterol 7α‐hydroxylase (